Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (Page 1 of 6) <br /> Type of Action ❑ Installation Test ❑ Repair Test ❑ Six Month Test ® 36 Month Test <br /> 1 . FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10184805 8/16/2019 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Food 4 Less <br /> Business Site Address City ZIP Code <br /> 610 Cherokee Ln . I Lodi 95240 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test (Print as shown on the ICC Certification) Phone # <br /> Michael McCarter (707) 545-5522 <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> Able Maintenance , Inc. - 312844 8819839 10/25/2019 <br /> III . SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID : (By tank number, stored product, etc.) A 87 B 91 C D <br /> Tank Containment <br /> Tightness Test Result ® Pass ❑ Fail ❑ NA ® Pass ❑ Fall ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Product Piping Containment <br /> Tightness Test Result ❑ Pass 0 Fail ❑ NA ❑ Pass m Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail la NA ❑ Pass ❑ Fail m NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail ® NA ❑ Pass ❑ Fail ® NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail m NA ❑ Pass ❑ Fail ® NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> i <br /> Vent Piping Containment <br /> i <br /> Tightness Test Result m Pass ❑ Fail ❑ NA ® Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> j <br /> Communication Test Result ❑ Pass ❑ Fail m NA ❑ Pass ❑ Fail ® NA ❑ Pass ❑ Fail ❑ NA ❑ Pass [] Fail ❑ NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑ Pass 0 Fail ❑ NA ❑ Pass ® Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass ❑ Fail m NA ❑ Pass ❑ Fail ® NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> Turbine / Product Piping Sump <br /> Tightness Test Result ® Pass ❑ Fail ❑ NA la Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> E Fill Riser Sump <br /> Tightness Test Result m Pass ❑ Fail ❑ NA ® Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> VENT / TRANSITION SUMP ID: a b C d <br /> Tightness Test Result ❑ Pass ❑ Fail m NA ❑ Pass ❑ Fail ® NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> UDC ID : 11 /2 23/4 35/6 4 <br /> Tightness Test Result ❑ Pass m Fail ❑ NA ❑ Pass ® Fail ❑ NA ❑ Pass m Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> UDC ID : 5 6 7 8 <br /> Tightness Test Result ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> UDC ID : 9 10 11 12 <br /> Tightness Test Result ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA <br /> All items marked "Fail" or "NA " must be explained in their respective "COMMENTS " section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDO STING Fr <br /> I hereby certify that the secondary containment was tested in accordance with Californiae�of Rejf6lations , title 24„[3 y00Ion <br /> 3 , Chapter 16 , Section 2637 and all the information contained herein is accurate. <br /> UST Service Technician Signature l 1 <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = IntemaprR U t i I pl ttlA ( fit Appli ble QDCg $ = Under- <br /> Dispenser Containment <br />