My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
3400
>
2300 - Underground Storage Tank Program
>
PR0518738
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2022 12:57:14 PM
Creation date
9/21/2020 10:28:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0518738
PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
CHEVRON STATION #212470/2222*
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATIONFORM ( Pagej5 of 6) <br /> XVI . LINE LEAK DETECTOR TESTING <br /> r Check this box if line leak detectors (LLD) are NOT installed . (Do not complete this section. ) Y N NA <br /> This section must be completed if LLDs are installed . <br /> Was a leak simulated to verify LLD performance? r <br /> Check all that apply.) Simulated leak rate verified : 3 GPG 1 . 1 GPG 0 . 2 GPH <br /> Was the testing apparatus properly calibrated? r <br /> For emergency generator tank systems , does the LLD create an audible and visual alarm when a leak is detected ? r r <br /> For mechanical LLDs , does the LLD restrict the flow through the pipe when a leak is detected? r r <br /> For electronic LLDs , does the turbine automatically shut off when a leak is detected? r r r <br /> For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected ? r r r <br /> For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? r r r <br /> For electronic LLDs , have all accessible wiring connections been visually inspected for kinks and breaks? r r r <br /> Were all items on the equipment manufacturer's maintenance checklist completed ? r r r <br /> Were all LLDs confirmed operational within regulatory requirements? r r r <br /> For any answer of "N " above, describe in section X111 how and when these issues were or will be corrected. <br /> XIII. COMMENTS <br /> i <br /> i <br /> XIV. VACUUM / PRESSURE/ HYDROSTATIC MONITORING EQUIPMENT TESTING <br /> r Check this box if VPH monitoring is NOT used . (Do not complete this section .) <br /> This section must be com leted if VPH monitoring is used to perform leak detection monitoring ! <br /> System Type Mark all that apply .) r Vacuum r Pressure r H drostatic <br /> Sensor Functionality Interstitial Communication <br /> Sensor lD Component(s) Monitored by this Sensor Tom{ Test <br /> r Pass r Fail r Pass r Fail <br /> r Pass r Fail r Pass r Fail <br /> r Pass r Fail r Pass EFail <br /> Pass rFail r Pass r Pass rFail r Pass <br /> r Pass r Fail r Pass r Fail <br /> r Pass r Fail r Pass r Fail <br /> r Pass r Fail r Pass r Fail <br /> r Pass r Fail r Pass r Fail <br /> r Pass r Fail r Pass r Fail <br /> r Pass r Fail r Pass r Fail <br /> r Pass r Fail r Pass qP r Fail <br /> r Simulated leak at far ends of the interstitial space . r Visual Inspection <br /> How was interstitial communication verified ? C Other Describe the method in section XV below. r Gau e <br /> Was the vacuum or pressure restored to operating levels in all interstitial spaces? r Yes r No (Describe the reason in section XV below.) <br /> For any answer of "N " above, describe in section Xlll how and when these issues were or will be corrected. <br /> XV. COMMENTS <br /> GPH = Gallons per hour, Y = Yes , N = No , NA = Not applicable , VPH = Vacuum /Pressure/ Hydrostatic, ID = Identification <br />
The URL can be used to link to this page
Your browser does not support the video tag.