My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
3400
>
2300 - Underground Storage Tank Program
>
PR0518738
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2022 12:57:14 PM
Creation date
9/21/2020 10:28:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0518738
PE
2361
FACILITY_ID
FA0014111
FACILITY_NAME
CHEVRON STATION #212470/2222*
STREET_NUMBER
3400
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
21306016
CURRENT_STATUS
01
SITE_LOCATION
3400 MACARTHUR DR
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Overfill Prevention Equipment Inspection <br /> .j�Tanknology 90% Flow Restriction Ball Float Overfill Prevention Device Inspection <br /> (Note the 90% BF manufatured by OPW will have a 1/8 inch breather hole) <br /> Store Information Testing Company <br /> Site Name: Chevron 212470 Name: TANKNOLOGY INC. <br /> Address: 3400 N MacArthur Drive Address: 11000 N. MOPAC EXPRESSWAY,SUITE 500 <br /> Tracy CA 95376 AUSTIN,TX 78759 <br /> Phone: Phone: 512 451-6334 <br /> 91 87 dsl <br /> 90% Flow Ball Float Manufacturer: OPW OPW OPW <br /> 90% Flow Ball Float Model: 53-VML-2 53-VML-2 53-VML-2 <br /> PART 1) Proper height setting calculation <br /> A. Determine maximum tank volume Tank Chart gallons 11849 15157 7817 A <br /> B. Max flow restriction requirement 90% .90 .90 .90 B <br /> for a ball float is 90% <br /> C. Multiply Maximum tank volume by 90% gallons 10664.100 13641.300 7035.300 C <br /> (AxB = C) <br /> D. Use tank chart or ATG to determine height of calculated inches 97.750 97.750 98.250 D <br /> volume <br /> E. Measure top of BF riser to tank bottom inches 160.500 156.500 142.000 E <br /> F. Measure top of BF riser to bottom of extractor cage inches 42.500 38.500 24.000 F <br /> threads <br /> G.Extractor cage bottom to tank bottom(E- F =G) inches 118.000 118.000 118.000 G <br /> H. Calculated min BF length (G- D= H) inches 20.250 20.250 19.750 H <br /> I.Actual measured BF length minus 1/2 inch inches 13.000 13.000 13.000 <br /> PART 2) Device certification criteria evaluation <br /> Criteria 1 Does ball float overfill prevention device meet the <br /> manufacturer's requirement? No No No <br /> Criteria 2 Does the BF pass a visual and mechanical inspection? <br /> Yes Yes Yes <br /> PART 3) Device Certification PASS/FAIL <br /> Technician certifies that the device is operationally <br /> compliant. If the response to Criteria 1 and 2 are YES <br /> Fail Fail Fail <br /> Comments: <br /> Ball floats are all at 95%. <br /> Tester: _E-dlwin Pineda Certification#: 63541 <br /> Signature: .rc_N�I} �`'`�� Test Date: 10/4/2018 <br /> VVO:2338727 <br /> WO:NW1-2338727 <br />
The URL can be used to link to this page
Your browser does not support the video tag.