My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 4:25:20 PM
Creation date
9/21/2020 11:08:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN 10At IN nvironniental Ilealt � Department <br /> Underground Storage Tank Program lnspec#ion Report <br /> Facility Name: Facility Phone : Date: <br /> Costco Wholesale #38 (Gas Station ) (209 ) 478-2040 March 13 , 2019 <br /> Facility Address : CERS ID: <br /> 1630 E Hammer Ln , Stockton , CA 95210 10749253 <br /> Inspection Contact: Title : Phone : <br /> Lisa Hurley Environmental Contact (425 ) 427 -7885 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION - Operating Permit 2371 - UST FACILITY - 1702 COMPLIANT <br /> Consent For: Consent Given By : <br /> Z Inspection O Photos O Samples Rick Sickels , Shipping and Receiving Manager <br /> Service Technician Onsite: Exp. Date: Designated Operator: Exp. Date : <br /> Chad White 02/23!2020 Mark Rasmussen 12/27/2019 <br /> Service Technician Manufacturer's Training : <br /> Veeder Root, 06/08/ 19 ; VMI , 05/23/ 19 ; SB , 05/30/20 <br /> CCR = Title 23 California Code of Regulations HSC = Health and Safely Code CFR = Code of Federal Regulations <br /> V = Violation R = Repeat violation COS = Corrected on site during inspection <br /> . <br /> . File' Revievv <br /> 101 HSC 25284 Failed to obtain a permit to operate from the EHD including but not limited to unpaid permit fees zV 1R 1 COS <br /> 102 HSC 25284(a) (3) (A)/(B) No written agreement between tank owner and tank operator to monitor the tank system V R r COS <br /> 103 HSC 25292. 27 25299.30 Failure to submit and maintain complete and current financial responsibility documents V R ICOS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current V - R COS <br /> 105 CCR 2632(d)(1 ) , Failed to have an approved UST monitoring plan IV R COS <br /> 2634(d) <br /> 106 CCR 2632(d)(2) , Failed to have an approved UST response plan IV R : COS <br /> 2634(e) <br /> 107 CCR 2632(d)(1 ) (C) Plot plan/site map not submitted or failed to completely show where monitoring is performed V R COS <br /> 108 CCR 2637, 2638(e) , Failed to notify the EHD 48 hours prior to conducting testing V R COS <br /> 2643(g) <br /> r1141 <br /> CCR 2637(a-d) , 2712 Failed to test secondary containment, or failed to maintain test records for 36 months V R COS <br /> CCR 2637(e) , 2637(0 Failed to submit "Secondary Containment Testing Report Form" within 30 days after the test V R COS <br /> CCR 2638(a) & (b) , Failed to test monitoring and leak detection equipment annually V r R COS <br /> 26410) <br /> HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance n V R COS <br /> 113 CCR 2638(c) , 2638(d) Failure to submit "Monitoring System Certification Form" within 30 days of completion of the test IV R COS <br /> 114 CCR 2636(0(3) , 2643(c) No 0. 1 gph annual line integrity test for pressurized piping , or within 30 days after repair V R COS <br /> (3) <br /> 115 CCR 2715(a) (1 ) (B) , "Designated Underground Storage Tank Operator Identification Form" not submitted within 30 days V R COS <br /> 2715(a) (3) <br /> 116 CCR 2715 Designated operator, service tech or installer did not possess current ICC certification V R z. COS <br /> 117 CCR 2663, 2712(b)(6) Failure to comply with tank lining. recordkeeping , and inspection requirements V R COS <br /> 118 CCR 2715(a)(1 ) (A) , Failure to submit the "Underground Storage Tank Statement of Understanding and Compliance Form" IV iR COS <br /> 2715(a) (2) <br /> 119 HSC 25299(a)(8) , Documents were falsified or misrepresented V IR COS <br /> 25299(b)(7) <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification IV I R COS <br /> 121 CCR 2712(0 Failed to submit a written response within 30 days of receiving an inspection report V R COS <br /> 122 CCR 2631 , 2640. 1 , Failure to submit and/or maintain documentation regarding compatibility for UST system components IV R COS <br /> 2665 , 2711 <br /> FA0024496 PRO518624 SCO01 03/1312019 <br /> EHD 23-01 Rev. 09/28/2018 Page 1 of 4 Underground Storage Tank Program OIR <br /> 1868E Hazelton Avenue j Stockton . California 952051 T 209 468-3420 1 F " 09 .1 0 L'> i „n, coil com <br />
The URL can be used to link to this page
Your browser does not support the video tag.