My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 4:25:20 PM
Creation date
9/21/2020 11:08:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN 'JO A Q U I N` Environinental Hedlfh Department <br /> 4 %f <br /> YUnd rgroux T�rtk ProOlt ar11 Inspection Repos# <br /> Facility Name: Facility Address: Date : <br /> Costco Wholesale #38 ( Gas Station ) 1630 E Hammer Ln , Stockton March 13 , 2019 <br /> J%Po <br /> 315 HSC 25291 (e) Water in secondary containment not removed , analyzed, and properly disposed of (pre-Jul 2003) 1V ri R COS <br /> 316 HSC 25290. 1 (c3) , Secondary containment not constructed to prevent water intrusion (after Jul 2003) , V R r COS <br /> 25290.2(c3) <br /> 317 CCR 2636, 2643(c)(1 ) , Line leak detector (LLD) not installed V R r ; COS <br /> 2666(f) <br /> 318 CCR 2636(f) (2) Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch V I R COS <br /> 319 CCR 26355 2637. 11 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested ■ V R COS <br /> 2665 , 2712 <br /> 320 CCR 2635 , 2637.2, Failure to comply with the installation, inspection , or record keeping of the overfill prevention , V R COS <br /> 2665 , 2712 <br /> 321 CCR 2635(b) (2) Overfill prevention was overridden V R c COS <br /> 322 HSC 25281 .6(a) Unburied below grade emergency generator system failed to meet exemption status I V r R COS <br /> 323 HSC 25283.5 (a) Unburied below grade UST system failed to meet exemption status V R r COS <br /> 324 CCR 2717. 1 (g) Tampered with red tag V R COS <br /> 325 CCR 2717. 1 (f) Deposited petroleum into a red tagged UST r, V 1R COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms V R COS <br /> 327 CCR 2631 . 1 UST system not compatible with the substance stored V IR 1 , COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements V r , R COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements : IV r R j COS <br /> 330 CCR 2636(f) , 2666(c) , No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm V , , R , , COS <br /> 2666(f) <br /> 331 CCR 2630(d) , 2641 (a) Liquid does not flow into the sump in the event of a leak (i.e . , failure to remove test boot) . 1V R COS <br /> 332 CCR 2631 (b&d) , Primary and/or secondary containment not constructed in accordance with the established standards ; V iIR i COS <br /> 2666(b&e) <br /> 333 CCR 2635 , 2636(b) , Failure to comply with the cathodic protection system requirements V = R COS <br /> 2662, 2712 <br /> 334 CCR 2666(b)(2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair V r:' R COS <br /> 335 CCR 2630, 26329 2643, Equipment or methods used to monitor the UST system are not certified by an independent third-party V - R COS <br /> 2644. 1 <br /> dingle Waled Non ?ressuried Piping <br /> 401 CCR 2636 (a)(3) , Suction piping not properly sloped or incorrectly located check valve V R - - COS <br /> 2641 (b) <br /> 402 CCR 2643 (d) No monitoring or record maintenance for single-walled conventional suction systems (pre-Jan 1984 ) . ; V R COS <br /> 403 CCR 2643 (d) , 2661 (f) Failure to conduct 0. 1 gph test for single-walled conventional suction systems (pre-Jan 1984) V 1R r COS <br /> 404 CCR 2643(e), 2661 (f) Biennial 0. 1 gph line integrity test for single-walled gravity piping not performed (pre-Jan 1984) V r . R COS <br /> , l3ftl�lr �ltgtl�tions <br /> 2010 See below Unlisted General violation 1V i R , COS <br /> rlt! F 1i1ELlTIONS< <br /> �Etf u$1, `i�SStl, <srtIAINOA NoticetaComPlyli <br /> Item # Remarks <br /> FA0024496 PRO518624 SCO01 03/13/2019 <br /> EHD 23-01 Rev, 0912812018 Page 3 of 4 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 T 209 468-3420 1 F 209 464 -013 �j I vnnN- sjceh . �.om <br />
The URL can be used to link to this page
Your browser does not support the video tag.