My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 4:25:20 PM
Creation date
9/21/2020 11:08:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 β(Gas Station)β
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PEIIRP1200-12 <br /> 4.2.4 Preparation. The procedures in this sec- 4.2.7 Test Equipment. Test equipment shall <br /> tion are general in nature and reflect the suggested include: <br /> vacuum levels and hold times for testing tank a vacuum-generating device that can be used in <br /> secondary containment areas. Consult tank manu- a Class I, Division 1 area capable of pulling 15 <br /> facturer and authority having jurisdiction (AHJ) inches of mercury (Hg)vacuum; <br /> guidelines before performing these tests as their <br /> requirements may differ. an automatic vacuum shutoff valve or vacuum <br /> regulator(The shutoff valve can be set to close at <br /> Determine if there is liquid present in the intersti- a predetermined safe level, preventing the pos- <br /> tial space. If liquid is found, determine if the fluid <br /> is water or product, and remove it to the extent <br /> Y <br /> practicable. <br /> The hydrostatic pressure from a tugh water table <br /> imposes inward pressure on the outer wall of a f <br /> UST. Applying a vacuum to the interstitial space <br /> of the tank creates additional pressure on the outer <br /> wall. These combined forces can damage the <br /> secondary tank wall when there is a large defined <br /> space between the primary and secondary tanks. <br /> Consequently, to prevent damage to the <br /> tank, <br /> important to observe the water table and associated +#_J <br /> recommended vacuum levels when testing. <br /> Vent the primary tank to atmosphere during the FIGURE 4-3. The vacuum gEiuge and control valve used <br /> for tank interstitial testing. <br /> test. βIn some installations, the tank interstitial space <br /> may be vented to minimize the buildup of conden- <br /> sation.In these cases, seal off any vent lines to the <br /> tank interstitial space prior to testing. <br /> Determine the volume of the tank. This informa- <br /> tion is available from facility records or the auto- R' ` <br /> matic tank gauge (ATG)readout. <br /> 4.2.5 Steel Tanks. Determine if the interstitial <br /> I <br /> space is a"tight wrap"design or a"110% contain- <br /> ment" design. Tanks with a 110% containment <br /> design should use the latest version of Steel Tank <br /> Institute's (STI) Recommended Practice R012, <br /> Recommended Practice for Interstitial Tightness <br /> Testing of Existing Underground Double Wall Steel <br /> Tanks for testing. - <br /> For tight wrap tanks, use the test method in this <br /> section. ' <br /> 4.2.6 Fiberglass Tanks, Determine if the inter- ` - <br /> stitial space is a "tight wrap" design or a "110% <br /> contaimnent"design.Either type of fiberglass tank so <br /> may use this test, or the latest version of Fiber- <br /> glass Tank & Pipe Institute's, Field Test Protocol <br /> for Testing the Annular Space of Installed Under- FIGURE 4-4. The plumber's plug provides a leak-tight <br /> ground Fiberglass Double and Triple-wall Tanks connection to draw a vacuum on the tank interstitial <br /> with Dry Annular Space, FT&PI 4101107 space. <br /> f <br /> 0 peLorg <br />
The URL can be used to link to this page
Your browser does not support the video tag.