My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
950
>
2200 - Hazardous Waste Program
>
PR0521562
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:47 AM
Creation date
9/21/2020 3:05:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0521562
PE
2220
FACILITY_ID
FA0006388
FACILITY_NAME
KWIK SERVE
STREET_NUMBER
950
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23406002
CURRENT_STATUS
01
SITE_LOCATION
950 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> COUNTY-! - <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> KWIK SERVE 950 W ELEVENTH ST. TRACY August 17, 2018 <br /> Treatment,Transport and Disposal <br /> 208 HSC 25200.3.1(c) Failure o laboratory to comply with hazardous waste treatment requirements V u R u COS <br /> 209 CCR 66262.34(d)(2) Failure to remove all hazardous waste from tanks.containers and containment upon facility closure ❑V ❑R o COS <br /> Preparedness and Prevention <br /> 301 CCR 66262.34(d)(2) Facility not maintained to minimize the release of a hazardous waste u V u R u COS <br /> 302 CCR 66262.34(d)(2) Failed to naintain required emergency equipment o V o R o COS <br /> 303 CCR 66262.34(d)(2) Failed to i naintain all communication or alarm systems,spill control,or decontamination equipment o V o R o COS <br /> 304 CCR 66262.34(d)(2) Failed to i naintain adequate aisle space for unobstructed response to emergencies ❑V u R COS <br /> Container Management <br /> 401 CCR 66262.34(d)(2) Failed to tore hazardous waste in a container that is in good condition o V o R u COS <br /> 402 CCR 66262.34(d)(2) Failed to tore hazardous waste in a compatible container o V o R o COS <br /> 403 CCR 66262.34(d)(2) Failed to I eep hazardous waste containers closed except when adding or removing hazardous waste o V o R o COS <br /> 404 CCR 66262.34(d)(2) Failed to i ispect hazardous waste storage areas at least weekly ❑V o R o COS <br /> 405 CCR 66262.34(d)(2) Failed to r ianage incompatible wastes in containers properly ❑V o R o COS <br /> 406 CCR 66261.7 Contamini ited container not marked with date emptied or managed within one year of being emptied o V o R o COS <br /> 407 CCR 66262.34(e)(1)(A) Satellite a umulation container not located near point of generation or under control of operator o V o R o COS <br /> 408 CCR 66262.34(e)(2) Satellite acumulation exceeded 55 gallons of HW(or one quart of acutely HW per waste stream V R COS <br /> Tank Management <br /> 501 CCR 66262.34(d)(2) No overfill prevention device on continuously fed hazardous waste tank o V o R o COS <br /> 502 CCR 66262.34(d)(2) Tank syst m inspections of discharge systems,monitoring equipment,and tank levels not done daily o V o R o COS <br /> 503 CCR 66262.34(d)(2) Tank systE m inspections of construction materials,fixtures,and surrounding areas not done weekly o V o R o COS <br /> 504 CCR 66262.34(d)(2) Failed to Maintain at least two feet of freeboard in uncovered tank with no secondary containment o V o R o COS <br /> 505 CCR 66262.34(f) Failed to mpletely label stationary hazardous waste tanks o V o R o COS <br /> Labeling and Storage <br /> 601 CCR 66262.34(d) Stored haz ardous waste onsite greater than 180 days ❑V o R D COS <br /> 602 CCR 66262.34(e)(1)(B) Stored sat (lite accumulated waste on site longer than one year or 180 days after fill date ❑V o R o COS <br /> 603 CCR 66262.34(e)(1)(C) Failed to rr ark initial accumulation start date on satellite containers o V ❑R o COS <br /> 604 CCR 66262.34(e)(3) Failed to rrrrk satellite containers with date filled within three days o V o R o COS <br /> 605 CCR 66262.34(f) Failed to cc mpletely label containers or portable tanks of hazardous waste o V o R o COS <br /> 606 CCR 66266.81(a)(3) Failed tom aet lead acid battery storage requirements for hazardous waste management exemption o V ❑R o COS <br /> 607 CCR 66266.81(b) Damaged lead acid batteries not properly managed and labeled o V o R o COS <br /> 608 CCR 66266.130 Failed to pr I operly manage used oil and fuel filters o V o R o COS <br /> 609 HSC 25143.2,25143.9 Failed to et requirements for claimed excluded recyclable materials o V o R o COS <br /> 610 CCR 66262.34(b)(1) Stored acui sly or extremely hazardous waste onsite greater than 90 days o V o R o COS <br /> 611 HSC 25200.3.1(b) Failure of 1E boratory to comply with hazardous waste accumulation area requirements D V o R ❑COS <br /> FA0006388 PR0521562 SCO01 08/17/2018 <br /> EHD 22-01 Rev.10/31/2017 Page 2 of 4 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Aven je I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).