My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BANNER
>
6437
>
2300 - Underground Storage Tank Program
>
PR0506004
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2021 11:25:58 AM
Creation date
9/22/2020 1:55:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0506004
PE
2361
FACILITY_ID
FA0007140
FACILITY_NAME
FLAG CITY SHELL*
STREET_NUMBER
6437
Direction
W
STREET_NAME
BANNER
STREET_TYPE
ST
City
LODI
Zip
95242
APN
05532019
CURRENT_STATUS
01
SITE_LOCATION
6437 W BANNER ST
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM ( Page 2 of 6) <br /> V. TANK SECONDARY CONTAINMENT INFORMATION <br /> Manufacturer Identify Tank ID from Section III for each Manufacturer <br /> Trusco A x❑ 1 B x❑ I C ❑x D ❑ <br /> A ❑ I B ❑ I C ❑ I D <br /> Test Method Used : ❑ Manufacturer Guidelines (Specify) : <br /> px Industry Code or Engineering Standard (Specify) : PEI / RP1200- 17/Glass/Steel Tank/- 10 " Hg . 2 Hours <br /> ❑ Engineered Method (Specify) : <br /> # of Attached Pages <br /> Attach the testing procedures and all documentation required to determine the results. 2 <br /> Tank Containment Testing Training and Certifications (List applicable certifications.) Expiration Date <br /> ICC Service Technician #5246802- UT 3/20/2021 <br /> Underground Storage Tank Tester License #90- 1120 12/31 /2019 <br /> VI . COMMENTS <br /> Provide any additional comments here. <br /> Tank A is a 20K Double Wall Glass/Steel , designated for Regular 87 Octane Gasoline . <br /> Tank B & C is a 20K Double Compartment, Double Wall Glass/Steel , with 1 OK designated for Super 91 Octane Gasoline <br /> and 1 OK designated for Diesel . <br /> Note : Tanks B & C is a Double Compartment with single Tank Secondary Containment . <br /> Note : Test time extended from 1 hour to 2 hours due to Tank Volumes of 20K. See Test Procedure Attachment for Tank <br /> Secondary Containment Test Time and Protocol . <br /> VII . PRODUCT PIPING CONTAINMENT TESTING INFORMATION <br /> Manufacturer Identify Tank ID from Section III for each Manufacturer <br /> Smith FRP A ❑x B ❑x C x❑ D ❑ <br /> A ❑ I B ❑ C ❑ I D ❑ <br /> Test Method Used : Zx Manufacturer Guidelines (Specify) : <br /> Bravo Systems Coated Steel UDC ' s . 3 Psi - 1 Hour <br /> ❑ Industry Code or Engineering Standard (Specify) : <br /> ❑ Engineered Method (Specify): <br /> # of Attached Pages <br /> Attach the testing procedures and all documentation required to determine the results. 2 <br /> Product Piping Containment Testing Training and Certifications (List applicable certifications) Expiration Date <br /> ICC Service Technician #5246802 - UT 3/20/2021 <br /> Under round Storage Tank Tester License #90 - 1120 12 /31 /2019 <br />[ Interstitial Communication Verification Method Used : <br /> NA-Section III -Sealed System at Termination end of Piping Runs at Bravo System Coated Steel UDC 's . <br /> VIII . COMMENTS <br /> Provide any additional comments here. <br /> * Section VII -See Test Procedure Attachment for Product Piping Test Pressure , Time and Protocol , for Fiberglass Piping <br /> Systems that terminate at Bravo System Coated Steel UDC 's . <br /> ID = Identification <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.