Laserfiche WebLink
SAN" J D�l+ �� I 11411" Environmental Health Department <br /> COUNTY— <br /> Underground <br /> �l O U N T Y-- <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> 7-ELEVEN INC#14113 3040 W BENJAMIN HOLT DR STOCKTON jlseptember 11 2019 <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3), Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 2641(b) <br /> 402 CCR 2643(d) Failure to conduct monitoring/maintain records for single-walled conventional suction(pre-1984) ❑V ❑R ❑COS <br /> 403 CCR 2643(d),2661(f) Failure to conduct 0.1 gph test for single-walled conventional suction systems(pre-Jan 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e),2661(f) 0.1-gph line test for single-walled gravity piping not performed biennialy or post repair(pre-1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d)Failed to have an approved UST monitoring plan. <br /> The monitoring plan is not current and/or not approved by the EHD. <br /> -Both monitoring plans list the panel as a TLS 350. The panel on site is a TLS 350R. <br /> -Both monitoring plans list the leak detector as a model LD2000. The leak detectors on site are both 99LD2000. <br /> The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). <br /> Immediately log into CERS, make the necessary changes, and submit for review by the EHD. <br /> This is a minor violation. <br /> 201 CCR 2712(b)(1-2)Failure to maintain monitoring, maintenance, and follow up action records. <br /> Maintenance and monitoring records for the last three years were not found on site. No work order was found for <br /> removal of liquid from spill containers in December 2018. According to the designated operator inspection report,this <br /> work was done under ticket#58138559. <br /> These records shall be maintained on site for at least three years. Monitoring records include: (1)date and time of all <br /> monitoring or sampling; (2)monitoring equipment calibration and maintenance records; (3)results of any visual <br /> observations; (4)results of sample analysis performed a lab or in the field; (5)logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations, or other test results; (6)results of inventory readings and <br /> reconciliations. <br /> Immediately locate and maintain all maintenance and monitoring records for the last three years on site and submit <br /> copies of the missing records to the EHD. <br /> This is a minor violation. <br /> FA0007461 PRO506497 SCO01 09/11/2019 <br /> EHD 23-01 Rev.08/27/2019 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />