My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
18754
>
2300 - Underground Storage Tank Program
>
PR0507164
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:36 AM
Creation date
9/22/2020 4:34:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0507164
PE
2361
FACILITY_ID
FA0007722
FACILITY_NAME
ORLANDOS
STREET_NUMBER
18754
Direction
E
STREET_NAME
STATE ROUTE 26
City
LINDEN
Zip
95236
APN
10517048
CURRENT_STATUS
01
SITE_LOCATION
18754 E HWY 26
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br /> SAN J DA U I N Environmental Hell 1p rtment <br /> - <br /> - COUhI f Y - <br /> `� 'It. �Fosb'`: � :' Potticfif5 f� r• ijW � ITcrd , <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> ORLANDOS (209) 887- 1100 July 02 , 2019 <br /> Facility Address : CERS ID : <br /> 18754 E HWY 26 , LINDEN , CA 95236 10182295 <br /> Inspection Contact: Title: Phone: <br /> Sam Orlando Owner (916) 708-4999 <br /> Inspection Type : F2361 <br /> rogram: <br /> ROUTINE INSPECTION - Operating Permit - UST FACILITY <br /> Consent For: Consent Given By: <br /> x❑ Inspection ❑x Photos ❑O Samples Sam Orlando , Owner <br /> Service Technician Onsite: Exp. Date: Designated Operator: Exp. Date : <br /> Ed Stearns 11 /19/2020 Greg Kaiser 10/ 10/2019 <br /> Service Technician Manufacturer's Training : <br /> VR , 08/31 /19 ; VMI , 06/20/20 , SB , 11 /29/19 <br /> CCR = Title 23 California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br /> V = Violation R = Repeat violation COS = Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284; CCR Failed to obtain a permit to operate from the EHD including but not limited to unpaid permit fees ❑ V ❑ R ❑ COS <br /> 2711 (d) <br /> 102 HSC 25284(a) (3) (A)/(B) No written agreement between tank owner and tank operator to monitor the tank system ❑ V ❑ R ❑ COS <br /> 103 HSC 25292. 21 25299.30 Failure to submit and maintain complete and current financial responsibility documents ❑ V ❑ R ❑ COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current ■ V ❑ R ❑ COS <br /> 105 CCR 2632(d) (1 ) , Failed to have an approved UST monitoring plan ❑ V ❑ R ❑ COS <br /> 2634 (d) <br /> 106 CCR 2632(d) (2) , Failed to have an approved UST response plan ❑ V ❑ R ❑ COS <br /> 2634 (e) <br /> 107 CCR 2632(d) , 2641 (h) , Plot plan/site map not submitted or failed to completely show where monitoring is performed ❑ V ❑ R ❑ COS <br /> 2711 (a) <br /> 108 CCR 2637, 2638(e) , Failed to notify the EHD 48 hours prior to conducting testing ❑ V ❑ R ❑ COS <br /> 2643(g) <br /> 109 CCR 2637 (a-d) , 2712 Failed to test secondary containment, or failed to maintain test records for 36 months ❑ V ❑ R ❑ COS <br /> 110 CCR 2637(e) , 2637(f) Failed to submit "Secondary Containment Testing Report Form" within 30 days after the test o V ❑ R ❑ COS <br /> 111 CCR 2638 , 2641 Q) , Failed to test monitoring and leak detection equipment every 12 months ❑ V ❑ R ❑ COS <br /> 2715 (f) <br /> 112 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance ❑ V ❑ R ❑ COS <br /> 113 CCR 2638(c) , 2638(d) Failure to submit "Monitoring System Certification Form" within 30 days of completion of the test ❑ V ❑ R ❑ COS <br /> 114 CCR 2636(f) (3) , 2643 (c) No 0 . 1 gph annual line integrity test for pressurized piping , or within 30 days after repair ❑ V ❑ R ❑ COS <br /> (3) <br /> 115 CCR 2715(a)(1 ) (B) , " Designated Underground Storage Tank Operator Identification Form" not submitted within 30 days ■ V ❑ R ❑ COS <br /> 2715(a)(3) <br /> 116 CCR 2715 Designated operator, service tech or installer did not possess current ICC certification ❑ V ❑ R ❑ COS <br /> 117 CCR 26633 2712(b) (6) Failure to comply with tank lining , recordkeeping , and inspection requirements ❑ V ❑ R ❑ COS <br /> 118 CCR 2715 (a) (1 ) (A) , Failure to submit the "Underground Storage Tank Statement of Understanding and Compliance Form" ❑ V ❑ R ❑ COS <br /> 2715(a) (2) <br /> 119 HSC 25299(a) (8) , Documents were falsified or misrepresented ❑ V ❑ R ❑ COS <br /> 25299(b) (7) <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification ❑ V ❑ R ❑ COS <br /> 121 CCR 27120 Failed to submit a written response within 30 days of receiving an inspection report ❑ V ❑ R ❑ COS <br /> FA0007722 PR0507164 SCO01 07/02/2019 <br /> EHD 23-01 Rev. 09/28/2018 Pagel of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.