Laserfiche WebLink
Environmental Health Department <br /> SAN JOAQUIN AM LADED <br /> COUNTY 637Iq FV <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address : Date: <br /> ORLANDOS 18754 E HWY 26 , LINDEN July 02 , 2019 <br /> UST System Observations <br /> 313 HSC 25290. 13 25290.21 Failure to construct, operate, and maintain primary containment as product-tight ❑ V ❑ R ❑ COS <br /> 25291 <br /> 314 HSC 25290. 1 , 25290.21 Failed to have secondary containment or secondary containment not tight ❑ V ❑ R ❑ COS <br /> 25291 <br /> 315 HSC 25291 (a) Water in secondary containment not removed , analyzed, and properly disposed of (pre-Jul 2003) ❑ V ❑ R ❑ COS <br /> 316 HSC 25290. 1 (c3), Secondary containment not constructed to prevent water intrusion (after Jul 2003) ❑ V ❑ R ❑ COS <br /> 25290.2(c3) <br /> 317 CCR 26361 2643(c)(1 ), Line leak detector (LLD) not installed ❑ V ❑ R ❑ COS <br /> 2666(f) <br /> 318 CCR 2666(c) , 2643(c) Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch ■ V ❑ R ■ COS <br /> (1 ) <br /> 319 CCR 2635, 2637. 13 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested ❑ V ❑ R ❑ COS <br /> 2665, 2712 <br /> 320 CCR 2635, 2637.21 Failure to comply with the installation, inspection, or record keeping of the overfill prevention ■ V ❑ R ❑ COS <br /> 2665, 2712 <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden ❑ V ❑ R ❑ COS <br /> 322 HSC 25281 .6(a) Unburied below grade emergency generator system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 324 CCR 2717. 1 (g) Tampered with red tag ❑ V ❑ R ❑ COS <br /> 325 CCR 2717A (0 Deposited petroleum into a red tagged UST ❑ V ❑ R ❑ COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑ V ❑ R ❑ COS <br /> 327 CCR 2631 . 1 , 2660(m) UST system not compatible with the substance stored ❑ V ❑ R ❑ COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑ V ❑ R ❑ COS <br /> 329 HSC 25298; CCR 2670, Failed to comply with all permanent closure requirements ❑ V ❑ R ❑ COS <br /> 2672 <br /> 330 CCR 2636(f) , 2666(c) , No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm ❑ V ❑ R ❑ COS <br /> 2666(f) <br /> 331 CCR 2630(d) , 2641 (a) Liquid does not flow into the sump in the event of a leak (i.e. , failure to remove test boot). ❑ V o R ❑ COS <br /> 332 CCR 2631 (b&d) , Primary and/or secondary containment not constructed in accordance with the established standards ❑ V ❑ R ❑ COS <br /> 2666(b&e) <br /> 333 CCR 2635, 2636(b), Failure to comply with the cathodic protection system requirements ❑ V ❑ R o COS <br /> 2662$ 2712 <br /> 334 CCR 2666(b)(2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair ❑ V ❑ R ❑ COS <br /> 335 CCR 2630, 2632, 2643, Equipment or methods used to monitor the UST system are not certified by an independent third-party ❑ V ❑ R ❑ COS <br /> 2644 . 1 <br /> Single -Walled Non -Pressurized Piping <br /> 401 CCR 2636(a) (3) , Suction piping not properly sloped or incorrectly located check valve ❑ V ❑ R ❑ COS <br /> 2641 (b) <br /> 402 CCR 2643(d) No monitoring or record maintenance for single-walled conventional suction systems (pre-Jan 1984) . ❑ V ❑ R ❑ COS <br /> 403 CCR 2643(d), 2661 (f) Failure to conduct 0. 1 gph test for single-walled conventional suction systems (pre-Jan 1984) ❑ V ❑ R ❑ COS <br /> 404 CCR 2643(e) , 2661 (f) Biennial 0. 1 gph line integrity test for single-walled gravity piping not performed (pre-Jan 1984) ❑ V ❑ R ❑ COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑ V ❑ R ❑ COS <br /> FA0007722 PR0507164 SCO01 07/02/2019 <br /> EHD 23-01 Rev. 09/28/2018 Page 3 of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd . com <br /> I <br />