My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
18754
>
2300 - Underground Storage Tank Program
>
PR0507164
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:36 AM
Creation date
9/22/2020 4:34:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0507164
PE
2361
FACILITY_ID
FA0007722
FACILITY_NAME
ORLANDOS
STREET_NUMBER
18754
Direction
E
STREET_NAME
STATE ROUTE 26
City
LINDEN
Zip
95236
APN
10517048
CURRENT_STATUS
01
SITE_LOCATION
18754 E HWY 26
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN <br /> J D �� I Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> ORLANDOS 18754 E HWY 26 , LINDEN July 02, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Facility Operating Permit is not current in CERS. <br /> -The California Department of Tax and Fee Administration (CDTFA, previously BOE)number listed on CERS <br /> (101319295)is not valid.The CDTFA number provided in the past was 44038631,which is closed and not valid. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br /> update the required information, and submit for review by the EHD. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> 115 CCR 2715(a)(1)(B),2715(a)(3)"Designated Underground Storage Tank Operator Identification Form"not submitted <br /> within 30 days. <br /> Stephanie Murphy is performing designated operator inspections at the facility and is not listed on the submitted <br /> statement of designated operators. Notification was not provided to the EHD within 30 days of the change.Any <br /> changes shall be reported to the EHD within 30 days. Immediately log into the California Environmental Reporting <br /> System (CERS)at http://cers.calepa.ca.gov and upload the notification identifying all the designated operators for <br /> this facility. <br /> This is a minor violation. <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The following was observed on the designated operator's monthly inspection reports: <br /> -Section VI of the report was missing date, name and signature of the owner/operator. <br /> During the visual inspection,the designated operator shall check all required testing and maintenance for the UST <br /> system have been completed and shall check all required items on the report. Ensure that designed operators <br /> performing visual inspections at this facility are including all of the required information on the reports. <br /> This is a minor violation. <br /> 318 CCR 2666(c), 2643(c)(1)Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch. <br /> The 87 and 91 product VMI line leak detectors failed to detect a leak when tested. All line leak detectors shall be <br /> capable of detecting a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak detector, retested <br /> it, and it passed. <br /> This was corrected on site. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> FA0007722 PR0507164 SCO01 07/02/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.