My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
J
>
JUBILEE
>
519
>
3600 - Recreational Health Program
>
PR0527878
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2020 8:29:26 AM
Creation date
9/23/2020 8:18:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0527878
PE
3612
FACILITY_ID
FA0018900
FACILITY_NAME
DESTINATIONS COMMUNITY
STREET_NUMBER
519
STREET_NAME
JUBILEE
STREET_TYPE
WAY
City
STOCKTON
Zip
95209
APN
08412008
CURRENT_STATUS
01
SITE_LOCATION
519 JUBILEE WAY
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br /> Environmental Health Department <br /> CCU 1T <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: DESTINATIONS COMMUNITY, 519 JUBILEE WAY, STOCKTON 95209 <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:There are no float valve assemblies in the skimmers, replace within 2 weeks. <br /> There are dead bugs and trash accumulating in the skimmer baskets, clean today. <br /> There are chlorine tablets in the skimmer baskets, remove them and start using the automatic chlorinator today. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> #29 Recirculation System Operation <br /> OBSERVATIONS:Water circulation in the pool is very low,this is causing algae to build up. Increase the water circulation in <br /> the wading pool today. <br /> CALCODE DESCRIPTION:Recirculation system shall be in operation whenever the pool is available for use and additional times as <br /> needed to maintain clear pool water. (CCR 65525) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 0 gpm Chlorine: 0 ppm Temp: ° F <br /> Cyanuric acid: <30 ppm pH: 7.0 Combined chlorine: 0 ppm <br /> NOTES <br /> Influent Pressure:4 <br /> Effluent Pressure: 0 <br /> Wading pool is to be closed until pH is above 7.2 and below 7.8; chlorine concentration is between 2.0 and 10.0 ppm. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: No one present to collect signature, <br /> EH Specialist: AARON GOODERHAM Phone: (209)468-3442 <br /> FA0018900 PR0527878 SCO01 07/16/2018 <br /> EHD 36-01 Rev.06/30/15 Page 2 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.