Laserfiche WebLink
W.O.# NW1-2338566 <br /> UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM(Page t of 6) <br /> Type of Action ❑Installation Test ❑Repair Test ❑Six Month Test 0 36 Month Test <br /> 1. FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10166021 12-3-18 <br /> Business Name(same as Facility Name or DBA-Do)ng Business As) <br /> 7-11 <br /> Business Site Address City ZIP Code <br /> 2360 w.grantline tracv 95356 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification.) Phone# <br /> jarrod Cooke (209)321 -2724 Ext <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 743160 8155550 4-6-19 <br /> III. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> Tank ID:(By tank number.stored product.etc.) A reg B sup C mul D <br /> Tank Containment <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Product Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA0 Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA 0 Pass ❑Fail ❑NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fall ❑NA ❑Pass ❑Fail ❑NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Communication Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Turbine I Product Piping Sump <br /> Tightness Test Result 0 Pass ❑Fail ❑NA 0 Pass ❑Fail ❑NA 0 Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Fill Riser Sump <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> Vent/Transition Sump ID: a b <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> UDC ID: 1 2 3 <br /> Tightness Test Result ❑Pass ❑Fait ❑NA ❑Pass ❑Fail ❑NA []Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> UDC ID: 5 <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> UDC ID: 9 110 11 12 <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA <br /> All items marked"Fail'or"WA"must be explained in their respective"COMMENTS"section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the secondary containment was tested in accordance with California Code of Regulations,title 23, <br /> division 3,chapter 16,section 263,7-Ind all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground storage tank,ICC=International Code Council, <br /> NA=Not applicable,UDC=Under-dispenser containment �1 <br /> IAN 08 2019 <br />