My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FRANK WEST
>
120
>
2300 - Underground Storage Tank Program
>
PR0515365
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2023 3:18:50 PM
Creation date
9/23/2020 1:37:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0515365
PE
2361
FACILITY_ID
FA0012107
FACILITY_NAME
A TEICHERT & SON INC*
STREET_NUMBER
120
STREET_NAME
FRANK WEST
STREET_TYPE
CIR
City
STOCKTON
Zip
95206
APN
19342006
CURRENT_STATUS
01
SITE_LOCATION
120 FRANK WEST CIR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J U A Q U I N Environmental Health Department <br /> C 0 U N T Y <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> A TEICHERT&SON INCA 120 FRANK WEST CIR, STOCKTON September 16, 2019 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 103 HSC 25292.2,25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> Financial responsibility documents have not been submitted to the EHD. The most recent financial responsibility <br /> documents in CERS are dated 1/10/18. Current financial responsibility documents are required to be submitted <br /> annually. Immediately log into the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov/, <br /> and upload the required documents. <br /> This is a minor violation. <br /> 113 CCR 2638(c), 2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the <br /> test. <br /> A monitoring system certification, and leak detector testing were performed on 9/17/18.A test report has not been <br /> submitted to the EHD or the California Environmental Reporting System (CERS).A copy of the test report must be <br /> submitted within 30 days of the test. Immediately provide this report to the EHD. <br /> This is a minor violation. <br /> 118 CCR 2715(a)(1)(A),2715(a)(2) Failure to submit the"Underground Storage Tank Statement of Understanding and <br /> Compliance Form". <br /> The Underground Storage Tank Statement of Understanding and Compliance Form was not found in CERS. This <br /> form must be uploaded to the California Environmental Reporting System (CERS). Immediately log into the <br /> California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov and upload the Underground <br /> Storage Tank Statement of Understanding and Compliance Form for this facility. <br /> This is a minor violation. <br /> 121 CCR 2712(f)Failure to implement corrections and submit written response within 30 days of receiving the report. <br /> An inspection was last done on 9/17/18 and an inspection report was issued identifying information to be submitted <br /> to bring this site into compliance. This information was required to be submitted by 10/16/18.This information has <br /> not been received.An operator that receives an inspection report shall have 30 days to submit a written response <br /> that includes a statement documenting corrective actions taken or proposing corrective actions which will be taken. <br /> Ensure that a written response documenting corrective actions taken or proposed is submitted within 30 days of <br /> receiving an inspection report. <br /> This is a Class II violation. <br /> 320 CCR 2635, 2637.2,2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> Overfill prevention testing has not been conducted. This testing was required to be conducted by October 13, 2018. <br /> Immediately schedule this testing and provide 48 hours notification to the EHD. Ensure all future testing is <br /> conducted within required time frames. <br /> This is a Class II violation. <br /> FA0012107 PR0515365 SCO01 09/16/2019 <br /> EHD 23-01 Rev.8/22/2019 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.