ELECTRICAL POWER SYMBOLS ELECTRICAL LIGHTING SYMBOLS SINGLE LINE DIAL. SYMBOLS ELECTRICAL GENERAL NOTES <br /> RECEPTACLES <br /> 20A, 125V SINGLE OUTLET, HUBBELL5361 OR EQUAL FUSE, RATING AS INDICATED 1. ALL ELECTRICAL SHALL BE INSTALLED IN ACCORDANCE WITH 2016 CBC, 2016 CGBC, DOLLAR, GENERAL <br /> (MOUNT +16" TO BOTTOM AS NOTED) <br /> # 2016 CEC, ALL APPLICABLE LOCAL CODES, AND AS DIRECTED BY THE PROJECT ENGINEER. <br /> 2' X 4' LAY-IN FLOURESCENT FIXTURE, VOLTAGE AS INDICATED, 2. ALL ELECTRICAL WORK REQUIRES CITY INSPECTION. ELECTRICAL WORK COVERED OR <br /> 20A, 125V DUPLEX OUTLET, HUBBELL #5362 OR EQUAL (DRAWN TO SCALE) GROUND WIRE EXTENDED AND CONNECTED TO ENCLOSED PRIOR TO CITY ELECTRICAL INSPECTION SHALL BE UNCOVERED FOR INSPECTION <br /> (MOUNT +16" TO BOTTOM OR AS NOTED) = APPROVED GROUND (#12 MINIMUM IF NOT SHOWN) AND REPLACED AT NO EXPENSE. STORE # 14661 <br /> 2' X 4' LAY-IN FLOURESCENT FIXTURE CONNECTED TO EMERGENCY <br /> 20A, 125V DUPLEX OUTLET, HUBBELL #5362 OR EQUAL - INTEGRAL GFCI CIRCUITRY LIGHTING CIRCUIT OR WITH A MIN. OF 90 MINUTES BATTERY BACK-UP, 3. BID ALTERNATE - EXISTING CONDITIONS OBSERVED AND IDENTIFIED DURING THE PREBID <br /> (MOUNT +16" TO BOTTOM OR AS NOTED) (DRAWN TO SCALE) 1/3 - POLE CIRCUIT BREAKER SITE INSPECTION THAT ARE NOT ACCORDING TO THE LATEST CODE REQUIREMENTS AND 1940 McHENRY AVENUE <br /> DOUBLE DUPLEX TWO 20A, 125V DUPLEX OUTLETS, HUBBELL #5362 2' X 2' LAY-IN FLOURESCENT FIXTURE, VOLTAGE AS INDICATED, ARE NOT NOTED ON THE DESIGN DRAWINGS SHALL BE INCLUDED WITH THE BID SUBMITTAL <br /> (MOUNT +16" TO BOTTOM OR AS NOTED) AS AN ALTERNATE. ESCALONE, CA <br /> (DRAWN TO SCALE) THERMAL OVERLOAD/HEATER ELEMENT <br /> SINGLE FACE EXIT SIGN, TYPE AS INDICATED, 4. ALL CONDUIT SHALL CONTAIN A CODE SIZE GROUND WIRE (#12 AWG MINIMUM). <br /> 30A, 120V, 1�, RECEPTACLE � ® SHADED PORTION INDICATES FACE OF THE EXIT SIGN. ARROW INDICATES DIRECTION. �,, <br /> TRANSFORMER 5. ALL CONDUIT RUNS TO BE MECHANICALLY AND ELECTRICALLY CONTINUOUS AND RUN <br /> EXIT LIGHT, SINGLE FACE - WALL MOUNTED. ARROW INDICATES DIRECTION. "yr PARALLEL Al PERPENDICULAR TO BUILDING LINES. <br /> O 30A, 250V, 10, RECEPTACLE � � SHADED PORTION INDICATES FACE OF THE EXIT SIGN. <br /> CIRCUIT BREAKER, LOW VOLTAGE (AS SPECIFIED), 6. ALL WIRE SPLICES, TAPS AND JOINTS SHALL BE MADE WITH APPROVED COMPRESSION <br /> ® SPECIAL PURPOSE RECEPTACLE 8 DOUBLE FACE EXIT SIGN, TYPE AS INDICATED DRAW-OUT TYPE TYPE CONNECTORS. "SCOTCH-LOK" TYPE CONNECTORS ARE APPROVED FOR CONNECTION <br /> (SHADED PORTION INDICATES FACE OF THE EXIT SIGN & ARROW INDICATES DIRECTION) TO LIGHT FIXTURES ONLY. <br /> �® FUSED DISCONNECT SWITCH <br /> C 20A, 250V, 10, RECEPTACLE 7. THE CONTRACTOR SHALL REPLACE Al REPAIR ALL WALLS, CEILINGS, DOORS, <br /> $A 20A, 120/277V, SPST TOGGLE TYPE SWITCH, SMALL LETTER INDICATES EQUIPMENT, WIRING, CONDUIT, ETC., WHICH ARE DAMAGED OR REMOVED BY CONTRACTOR <br /> SWITCH LEG (MOUNT AT +46" TO BOTTOM OR AS NOTED) CIRCUIT BREAKER, MEDIUM VOLTAGE (AS SPECIFIED), TO THE SATISFACTION OF THE PROJECT ENGINEER. <br /> 30A, 250V, 32, TWIST LOCK RECEPTACLE DRAW-OUT TYPE <br /> $3 20A, 120/277V, 3-WAY TOGGLE TYPE SWITCH 8. ALL LAY-IN TYPE LIGHT FIXTURES SHALL BE SECURED WITH SCREWS IN ALL 4 CORNERS <br /> 480V, 10, RECEPTACLE AMPS/kW AS NOTED <br /> MOUNT AT +46" TO BOTTOM OR AS NOTED) DISCONNECT SWITCH AND WITH 2 SLACK WIRES ON DIAGONAL CORNERS, PER NEC AND IBC REQUIRMENTS. <br /> DIMMER SWITCH, TYPE AND RATING AS NOTED 9. THE CONTRACTOR SHALL REMOVE ALL LIGHT FIXTURE BALLASTS CONTAINING. PCB AS <br /> $D DIRECTED BY THE PROJECT ENGINEER. IN BRIEF, THE CONTRACTOR SHALL REMOVE THE <br /> ■ 480V, 30, RECEPTACLE AMPS/kW AS NOTED (MOUNT AT +46" TO BOTTOM OR AS NOTED) VFD VARIABLE FREQUENCY DRIVE BALLASTS AND DEPOSIT THEM IN A SPECIALLY MARKED DRUM FURNISHED BY THE <br /> PROJECT MANAGER AT THE JOB SITE. <br /> K <br /> 20A, 120/277V, KEYED SWITCH STARTER <br /> BOX AROUND ANY OUTLET INDICATES OUTLETS INSTALLED IN FLOOR (MOUNT AT +46" TO BOTTOM OR AS NOTED) 10. ALL MATERIALS SHALL BE NEW AND UNUSED, AND OF THE BEST QUALITY. ALL MATERIAL <br /> INSTALLED SHALL BE U.L. LISTED OR AS REQUIRED BY LOCAL BUILDING CODES. <br /> 20A, 250V, 30, TWIST LOCK RECEPTACLE $OS WALL MOUNTED OCCUPANCY SENSOR WITH MANUAL OVERRIDE SWITCH SPECIAL SYSTEMS SYMBOLS 11. ALL CONDUIT ROUTED THROUGH THE ROOF OR OUTSIDE WALL SHALL BE MADE <br /> (MOUNT AT +46" TO BOTTOM OR AS NOTED) <br /> WATERTIGHT. OWNER <br /> 250V, 10, RECEPTACLE AMPS/kW AS NOTED OS CEILING MOUNTED OCCUPANCY SENSOR 12. ALL CONCRETE AND BLOCK WALL PENETRATIONS SHALL BE CORE DRILLED. COORDIANTE <br /> GB SECURITY SYSTEM GLASS BREAK SENSOR WITH LANDLORD PRIOR TO CORE DRILLING. <br /> O 250V, 30, RECEPTACLE AMPS/kW AS NOTED O-i WALL MOUNTED LIGHT FIXTURE 13. THE CONTRACTOR SHALL PROVIDE ALL FUSES AND CIRCUIT BREAKERS WHERE REQUIRED <br /> CR SECURITY SYSTEM CARD READER BY THE NEW CONSTRUCTION DOCUMENTATIONS. <br /> OTHER POWER SYMBOLS O 14. VERIFY VOLTAGE, CURRENT AND PHASES FOR ALL EQUIPMENT TO BE INSTALLED INCLUDING DOLLAR GENERAL <br /> CEILING MOUNTED LIGHT FIXTURE OWNER FURNISHED EQUIPMENT. VERIFY PROPER ROTATION AS DIRECTED BY THE PROJECT 100 MISSION RIDGE <br /> $M TOGGLE TYPE MANUAL MOTOR TYPE SWITCH WITH THERMAL OVERLOAD PROTECTION KP SECURITY SYSTEM KEYPAD ENGINEER PRIOR TO ENERGIZING MOTOR DRIVEN EQUIPMENT. <br /> WITH LOCK-OUT KIT, TYPE AS NOTED (MOUNT AT +46" TO BOTTOM OR AS NOTED) C�7GOODLETTSVILLE, TN 37072 <br /> EMERGENCY LIGHT FIXTURE WITH TWIN HEAD, BATTERY AND CHARGER, WALL MOUNTED 15. ALL EMERGENCY CIRCUIT J-BOX COVERS TO BE PAINTED BLUE AND THE CONDUIT TO <br /> JUNCTION BOX 4 11/16" SQ. X 2 1/8" D (MINIMUM) <br /> O MD MOTION DETECTOR <br /> HAVE A BLUE STRIPE EVERY 30'-0". <br /> PP POWER PACK FOR CEILING MOUNTED OCCUPANCY SENSOR MIC MICROPHONE JACK 16. ALL ELECTRICAL PANELS, DISCONNECTS, CABINETS, CONTROLS, RECEPTACLES, J-BOXES, <br /> ISI EXTERNALLY OPERATED FUSIBLE DISCONNECT SWITCH, SIZE AND ETC. SHALL BE MARKED, TAGGED AND IDENTIFIED. NOTE FEEDER SOURCE WHERE <br /> u TYPE AS NOTED APPLICABLE. <br /> P® <br /> COMBINATION MAGNETIC STARTER AND FUSIBLE DISCONNECT SWITCH, SIZE AND SOUND SYSTEM SPEAKER JACK <br /> CONTROL DIAGRAM SYMBOLS 17. POWER ACTIVATED ANCHORS ("RAMSET") SHALL NOT BE USED WITHIN ANY BUILDINGS OR REVISIONS <br /> TYPE AS NOTED <br /> DS DOOR SWITCH/CONTACT STRUCTURES. <br /> ® SINGLE PHASE STARTER W/ H.O.A. 18. CONTRACTOR SHALL FIELD VERIFY ROUTING/LOCATION OF ALL CONDUIT AND EQUIPMENT <br /> PRIOR TO ORDERING MATERIALS. <br /> TC TIME CLOCK <br /> U MOTOR 19. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES AS REQUIRED. <br /> E2 VARIABLE FREQUENCY DRIVE �• LIMIT SW. N.O. Da CCTV SYSTEM CAMERA 20. CONTRACTOR SHALL PROVIDE ALL MATERIALS EXCEPT AS NOTED AND MAKE ALL <br /> NECESSARY CONNECTIONS TO NEWLY INSTALLED EQUIPMENT. <br /> ABBREVIATIONS -� LIMIT SW. N.C. <br /> O INTERCOM SPEAKER 21. THE OWNER MUST APPROVE ALL POWER Al SAFETY SYSTEM OUTAGES REQUIRED TO <br /> COMPLETE THE PROJECT. <br /> MR MUD RING ONLY 22. UPON COMPLETION OF THE PROJECT, ALL CHANGES SHALL BE DOCUMENTED, AND <br /> • LIMIT SW. HELD OPEN REDLINED AS-BUILT DRAWINGS SHALL BE TURNED OVER TO THE OWNER BY THE <br /> A AMPERES ©G COMBINATION CLOCK & INTERCOM SPEAKER CONTRACTOR. <br /> AC AT 6" ABOVE COUNTER • (WALL MOUNTED) 23. CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR, PATCHING, AND PAINTING OF ALL <br /> �— LIMIT SW. HELD CLOSED FINISHES AFFECTED BY THIS WORK INCLUDING THE RESEALING OF FIRE WALL BREACHES. <br /> AG ABOVE GROUND <br /> AP WIRELESS ACCESS POINT 24. CONTRACTOR SHALL FIELD VERIFY LOCATIONS OF ALL EXISTING UNUSED CONDUIT AND <br /> AIC AMPS INTERRUPTING CURRENT �• TIMER CONTACT ON DELAY W <br /> N.C.T.C. J-BOXES AND REUSE THE SAME AS NECESSARY. <br /> C.B. CIRCUIT BREAKER TIMER CONTACT ON DELAY /25. ALL WIRING SHALL BE DUAL RATED THHN THWN STRANDED COPPER UNLESS NOTED <br /> CKT CIRCUIT ~� N.C.T.0. OTHERWISE. <br /> Cl CEILING COMMUNICATIONS SYMBOLS 26. WIRE COLOR CODE: <br /> CU COPPER • THERMAL SW, N.O. <br /> A) 208Y/120V 480Y/277V <br /> EDF ELECTRIC DRINKING FOUNTAINPHASE A BLACK BROWN <br /> THERMAL SW. N.C. Zk COMBINATION TELEPHONE/DATA OUTLET AT +16" TO BOTTOM (OR AS NOTED) PHASE B RED ORANGE <br /> PHASE C BLUE YELLOW <br /> E PREFIX FOR EMERGENCY <br /> EC EMPTY CONDUIT WITH PULL STRING0-7 NEUTRAL WHITE GRAY <br /> o PRESSURE SW. N.O. 1j FLOOR MOUNTED TELEPHONE OUTLET GROUND GREEN GREEN CONSULTANT <br /> EMO EMERGENCY POWER-OFF �� B) <br /> IX TELEPHONE OUTLET AT +16" TO BOTTOM (OR AS NOTED) CONTROL------------------------- RED <br /> EX EXISTING PRESSURE SW. N.C. Zee <br /> (X INDICATES NUMBER OF JACKS, IF MORE THAN ONE) NEUTRAL------------------------- WHITE <br /> FOT FIBER OPTIC TRANSMITTERPOWER --------------------------BLACK Engineering <br /> DATA OUTLET AT +16" <br /> � <br /> LEVEL SW. N.O. �X (X INDICATES NUMBER OFOJAOCKS ,, IF(OR MORE THO <br /> FU FUSE AN ONE) EXTERNALLY ENERGIZED CONTROL WIRE------ YELLOW E E Group, LLC• <br /> FWE FURNISHED WITH EQUIPMENT 27. TELEPHONE AND DATA CABLE: <br /> LEVEL SW. N.C. A) IN SHOP AREAS-THE CONTRACTOR SHALL PULL ALL TELEPHONE AND DATA CABLE AS 7 <br /> GFCIGROUND FAULT CIRCUIT INTERRUPTER FURNISHED BY THE OWNER AND COIL 15 FEET AT EACH END. MARK AND TAG BOTH ENDS <br /> GROUNDING SYMBOLS AS DIRECTED BY THE PROJECT ENGINEER. Suit S Alma School Road, <br /> GFP GROUND FAULT PROTECTION o FLOW SW. N.O. Suite 120 V. 480.222.8835 <br /> B) IN OFFICE AREAS-INSTALL OUTLET BOX FOR TELEPHONE AND DATA WHERE SHOWN ON Mesa, Arizona 85210 F. 480.222.8836 <br /> GND GROUND THE DRAWINGS AND PROVIDE PULL STRING FROM OUTLET BOX TO ABOVE CEILING. PUNCH 20021 EO1.dwg <br /> HPC HIGH PRESSURE CONTACT 7 FLOW SW. N.C. HOLES THROUGH CROSS MEMBERS, INSTALL GROMMETS AND ROUTE PULL STRING THROUGH <br /> O GROUNDING ROD TEST WELL GROMMETS, CABLE TO BE INSTALLED BY OWNER. SEAL <br /> IG ISOLATED GROUND TW <br /> 28. PRIME AND PAINT ALL EXPOSED UNFINISHED METAL PARTS, AS DIRECTED BY THE PROJECT ` <br /> KA KILOAMPERES ENGINEER. <br /> NORMALLY OPEN PUSHBUTTON (MOMENTARY) • EXOTHERMIC WELD PROFESS/pNq <br /> kVA KILOVOLT - AMPERES 29. ALL MOUNTINGS HEIGHTS FOR BOXES ARE FROM FINISHED FLOOR TO THE CENTER OF BOX, �F,� MUK Sl �. <br /> n I � UNLESS OTHERWISE NOTED. �� <br /> 0 NORMALLY CLOSED PUSHBUTTON (MOMENTARY) <br /> kW KILOWATT T—T GROUND BUS 30. ALL TRASH AND DEBRIS SHALL BE REMOVED FROM THE BUILDING AT THE END OF EACH v <br /> LFMC LIQUIDTIGHT FLEXIBLE METAL CONDUIT DAY OR AS DIRECTED BY THE CONSTRUCTION COORDINATOR. E18714 <br /> • TIMER CONTACT OFF DELAY EXP.03-31-21 <br /> LT LIQUID TIGHT CONDUIT N.C.T.C. EARTH/CHASIS GROUND 31. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. <br /> F <br /> LTG LIGHTING NI CEROCONTACT OFF DELAY = 32. 4" HOUSE KEEPING PADS SHALL BE FURNISHED FOR ALL FLOOR MOUNTED ELECTRICAL `l'TgTF�ECTR <br /> ICP <br /> MCS MOLDED CASE SWITCH EQUIPMENT, BY OTHERS. OF CA��F <br /> M.O. MANUALLY OPERATED OO FOOT SW. N.O. GROUNDING RISER UP TO LIGHTNING PROTECTION 33. REFER TO INSTRUMENTATION AND CONTROL DRAWINGS FOR MOTOR STARTER SCHEMATICS. <br /> MT MOUNT O�Q FOOT SW. N.C. <br /> NF NON FUSED MISCELLANEOUS SYMBOLS <br /> NL NIGHT LIGHT G PILOT LIGHT <br /> PC POWER CENTER \ 0 _ 2 - POSITION SELECT SWITCH <br /> sm <br /> PNL PANEL / ARCHITECTS <br /> PWR POWER <br /> +1_ 0 <br /> 1 REVISION NOTE TAG. 2423 Edwards Street <br /> REC RECEPTACLE — 3 - POSITION SELECT SWITCH Berkeley, CA 94702 <br /> RGS RIGID GALVANIZED STEEL do <br /> Q O O KEYED NOTES T: 510.655. 1922 <br /> SB STRAIGHT BLADE o <br /> ILLUMINATED PUSH BUTTON <br /> SES SERVICE ENTRANCE SECTION TITLESYMBOLS, <br /> TL TWIST LOCK NOTE: <br /> PILOT LIGHT 75 CONDUIT TYPES ABBREVIATIONS AND <br /> TTB TELEPHONE TERMINAL BOARD <br /> Q UC UNDER COUNTER NOT ALL SYMBOLS, ABBREVIATIONS AND NOTES APPLY TO THIS PROJECT. GENERAL NOTES <br /> CD � <br /> CM USB USB PORT (WITH DUPLEX RECEPTACLE) o- ,U� PILOT LIGHT, PUSH TO TEST UNDERGROUND CONDUIT ISSUED <br /> SHEET <br /> o _q <br /> V VOLTS <br /> CONDUIT UP <br /> LU CONDUIT DOWN 7/24/2020 <br /> � <br /> N o VCB VACUUM CIRCUIT BREAKER RELAY COIL <br /> �o HOME RUM TO PANELBOARD OR AS NOTED <br /> SUBMITTAL <br /> VFD VARIABLE FREQUENCY DRIVE <br /> TN CONDUIT STUB-OUT, MARK AND CAP AS DIRECTED <br /> CD <br /> N WH WATER HEATER STARTER COIL WITH OVERLOAD BREAK IN CONDUIT <br /> oa EOO 1 <br /> WP WEATHERPROOF " � <br /> JOB NO. <br /> o a) <br /> E XFMR TRANSFORMER <br /> 20021 <br /> COPYRIGHT© PSM ARCHITECTS, INC 2020 <br />