GENERAL NOTES
<br /> -- 1. INSTALL ALL WORK IN ACCORDANCE WITH ALL CODES AND AS PER MANUFACTURER'S WRITTEN INSTRUCTIONS.MAINTAIN O MANUFACTURER'S SPECIFIED CLEARANCES FOR ALL EQUIPMENT. CD
<br /> - 2. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS SHOWN ON DRAWINGS AND TO REPORT ANY DISCREPANCIES TO
<br /> - - - ARCHITECT AND/OR SAFEWAY REPRESENTATIVE
<br /> I + DEMOLITION NOTES N
<br /> 1. VERIFY EXTENT OF DEMOLITION w/SAFEWAY REPRESENTATIVE BEFORE COMMENCING. 00 r-
<br /> 2. PATCH,REPAIR,AND CLEAN FLOORS AND WALLS TO MATCH EXISTING.
<br /> 1
<br /> 3. VERIFY DISPOSITION OF REMOVED EQUIPMENT wISAFEWAY REPRESENTATIVE. `,O �c
<br /> N ^^ V
<br /> 0GENERAL ELECTRICAL NOTES o
<br /> - . 1. ALL WIRING SHALL BE RUN IN METALLIC CONDUIT.CONCEAL IN WALLS&CEILINGS IN FINISHED AREAS.MC CABLE MAY BE RUN ,n .� X
<br /> O O -. CONCEALED ABOVE CEILINGS OR IN WALLS WHERE NOT SUBJECT TO PHYSICAL DAMAGE. vi W �+
<br /> O O 2. ALL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, PARALLEL&PERPENDICULAR TO BUILDING STRUCTURE.
<br /> 3, MINIMUM CONDUIT SIZE SHALL BE 314",UNLESS NOTED OTHERWISE.MINIMUM WIRE SIZE SHALL BE#12 AWG THHNfrHWN TYPE,UNLESS
<br /> _ NEW CURB TO MATCH NOTED OTHERWISE.ALL WIRING TO BE COPPER.ALL WIRE SIZE SHOWN ON THE ELECTRICAL EQUIPMENT NOTES ARE INTENDED TO BE
<br /> EXISTING IN SIZE,MATERIAL, THE MINIMUM ACCEPTABLE WIRE SIZE.
<br /> REMOVE CURB.PATCH, REMOVE FLOOR SINK AND TRAP. REMOVE CURB.PATCH, &FINISH.SEE DTL 31A1
<br /> REPAIR,AND FINISH FLOOR PATCH, REPAIR,AND FINISH REPAIR AND FINISH FLOOR 4. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2016 CALIFORNIA ELECTRICAL CODE,THE LATEST STATE CODES,AND LOCAL
<br /> EXISTING COLUMN CODES.
<br /> 70 MATCH EXISTING------ FLOOR.7d MATCH EXISTING TO MATCH EXISTING
<br /> ---- ___ �`--- _ --_ l O 5. ALL ELECTRICAL EQUIPMENT,INCLUDING,BUT NOT LIMITED TO CONDUIT,WIRE,BOXES,AND FITTINGS,SHALL BE NEW AND FREE OF
<br /> _ _ DEFECTS,SHALL BEAR THE UL LABEL,AND SHALL MEET NEMA AND ANSI STANDARDS. U
<br /> -------- ---------Z
<br /> -�- .`.._--..,.....
<br /> k II II 111 II T ___-_
<br /> IL__-� n IL----_ 1 ------ --------------- 6. ALL WORK AND MATERIALS SHALL BE GUARANTEED FREE FROM DEFECTS FOR A MINIMUM PERIOD OF ONE YEAR UNLESS NOTED
<br /> u------I 1------1 i----- l i -� CD
<br /> OTHERWISE. • ' J
<br /> !----4L----------i--------4L---------�---- -41 u -- 7. THE COLORS OF ALL RECEPTACLES AND DEVICE PLATES SHALL MATCH EXISTING.
<br /> 11 I I 1 I I ------------------------------------------�
<br /> I i i i I --- --= 8. CONTRACTOR TO VERIFY THAT NO PIPING,DUCTWORK,OR ANY OTHER MECHANICALIPLUMBING EQUIPMENT IS RUN DIRECTLY ABOVE
<br /> ----- - -----_..,.....-------------- ----------- - ELECTRICAL PANELS. \1
<br /> EXIST FLOOR SINK NEW FLOOR SINK HALF-IN NEW 12'EXCEL MERCHAN EE ELEC
<br /> DISCONNECT AND REMOVE REMOVE FLOOR SINK AND TRAP. DISCONNECT AND REMOVE HALF-OUT.EXTEND EXISTING RO DRAIN TO NEW 9. WHERE EXISTING EQUIPMENT IS SHOWN TO BE RELOCATED,ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUIT,JUNCTION
<br /> NEW 12'EXC�DRAI
<br /> EE ELEC EQUIP ---� BOXES,CABLE,&ACCESSORIES AS REQUIRED TO REVISE EXISTING CIRCUITING TO ACCOMMODATE NEW LOCATION OF EQUIPMENT
<br /> 12'REFRIGERATED CASE CAP PIPE WATERTIGHT.PATCH, 12'REFRIGERATED CASESANITARY PIPE TO NEW FLOOR SINK.SEE ANCHORING DETAIL 41A1.
<br /> NO U � STIINNG�LOOR
<br /> REPAIR,AND FINISH FLOOR TO SINK.SEE ANCHORING DETAIL 41A1.VERIFY FLOOR SINK. FIELD VERIFY VERIFY LOCATION OF EQUIPMENT WISAFEWAY 10, ELECTRICAL CONTRACTOR TO VERIFY IN THE FIELD ALL RECEPTACLES&JUNCTION BOXES TO BE REUSED OR RELOCATED
<br /> MATCH EXISTING LOCATION OF EQUIPMENT W15AFEWAY PROJECT LOCATION OF SANITARY PIPE. PROJECT MANAGER PRIOR TO INSTALLATION ACCORDINGLY WITH MOD#PIED RETAIL AREA LAYOUT. ANY FLOOR RECEPTACLE OR JUNCTION BOX NOT IN USE SHOULD BE REMOVED,
<br /> rl
<br /> MANAGER PRIOR TO INSTALLATION SEE DTL 51A1 &61A1 AND FLOOR SHOULD BE PATCHED FLUSH WITH MATERIAL TO MATCH EXISTING.
<br /> 11. VERIFY ALL WORK TO BE DONE WITH SAFEWAY REPRESENTATIVE BEFORE PROCEEDING.
<br /> 1
<br /> DEMOLITION PLAN 2 EQUIPMENT PLAN 12. ELECTRICAL CONTRACTOR IS TO PROVIDE GFI PROTECTION FOR EQUIPMENT RECEPTACLES PER THE 2016 CALIFORNIA ELECTRIC U �
<br /> CODE. O N
<br /> Al SCALE: 114"=1'-0" p11 SCALE: 114"= V-0" 13. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY THE EXISTING ELECTRICAL PANELS TO DETERMINE THE PROPER LOCATION FOR THE m
<br /> -------- DASHED LINE INDICATES EQUIPMENT TO BE REMOVED. NEW CIRCUITS.VERIFICATION SHALL INCLUDE MONITORING OF THE ELECTRICAL LOAD WITHIN THE PANEL,UNDER FULL LOAD,TO J I
<br /> p
<br /> VERIFYwISAFEWAY REP THE EQUIPMENTTO BE RELOCATED. CONFIRM SPARE CAPACITY AS WELL AS THE PHYSICAL SPACE TO ADD BREAKERS.RELOCATE EXISTING BREAKERS AS NECESSARY OR Q 00
<br /> REQUIRED TO FIND THE CORRECT SPACE,PROVIDE MONITORING RESULTS TO THE SAFEWAY PROJECT MANAGER,AND TO THE
<br /> ARCH ITECTIENGINEER. W 0)
<br /> ELECTRICAL EQUIPMENT NOTES Q o 0 w
<br /> � z F-
<br /> 1. WHERE EXISTING EQUIPMENT IS SHOWN TO BE RELOCATED, ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUIT,JUNCTION Z 0 0
<br /> BOXES, POWER POLES, CABLE AND ACCESSORIES AS REQUIRED TO REVISE EXISTING CIRCUITING AND ACCOMMODATE NEW �i ■ z
<br /> LOCATION OF EQUIPMENT. 69 � '' 0 i OzQ Q
<br /> 2. NOT USED Z (� 0 z
<br /> co
<br /> 3. ELECTRICAL CONTRACTOR SHALL PROVIDE FOR NEW EXCEL SERVICE MERCHANDISER 12'SMGT(2)HARDWIRE CONNECTIONS WITH z W Q
<br /> _
<br /> s J
<br /> 2#12, 1412G, 314"C., EACH TO EXISTING PANEL. CONNECT TO (2) EXISTING SPARE 20A, 1 POLE CIRCUIT BREAKER FOR CIRCUIT LC) 11 z
<br /> PROTECTION. PROVIDE TYPED,UPDATED PANEL SCHEDULE FOR ENTIRE PANEL AFTER INSTALLATION. U Q
<br /> T
<br /> ELECTRICAL EQUIPMENT SCHEDULE
<br /> 3-N0. 14 SMS OR BETTER,
<br /> � Z
<br /> TYP.EA. L3x3 v DESCRIPTION AMPS VOLTS PHASE: CYCLE PLUG RECEPT LOCATION BREAKER `z W
<br /> FIXTURE
<br /> L3x3x0'4"EA.CORNER FIXTURE RAIL SIZW N
<br /> OF OF FIXTURE WITH
<br /> ANCHOR TO SLAB AS FIXTURE RAILILEG ANCHOR EA.CORNER 12'EXCEL SERVICE 1,91 320 1 60 HZ HARDWIRE NONE EXISTING 20A11P C) _
<br /> NOTED SLAB OF FIXTURE TO SLAB MERCHANDISER UNGROUND o Q
<br /> AS NOTED SMGT-HUSSMANN 1.47 120 1 60 HZ HARDWIRE NONE CONDUIT 20A11P r _j
<br /> LLI0LLI
<br /> EQUIPMENT SCHEDULE ti z
<br /> W > Wco Q
<br /> #4 REBAR CONT.
<br /> EQ# COUNT ITEM NAME MANUFACTURER MODEL 8 rn
<br /> #4 EPDXY DOWELS INTO 2 12'EXCEL SERVICE MERCHANDISER HUSSMANN SMGT 00 Q Z
<br /> Wl3-12'EMBEEXISTING ,TYP.0SLAB a�24"O.C. PLUMBING FIXTURE SCHEDULE w } W a
<br /> W13-112"EMBED,TYP.USE
<br /> w Q
<br /> a • a SIMPSON SET-XP EPDXY PER ICC
<br /> x 4 d REPORT NO.ESR-2508.SPECIAL SLAB z � W
<br /> = a a a INSPECTION NOT REQUIRED ANCHOR TO RAIL/LEG ANCHOR THROUGH BASE U h Z
<br /> d ° FINISH ON CURB TO MATCH ITEM NAME MANUFACTURER MODEL REMARKS w IW z 0
<br /> 12"x12"x6"DEEP CAST IRON BODY WHITE -� Q Q w
<br /> d E00
<br /> XISTING. IF EPDXY IS TO O Lu W
<br /> BE INSTALLED PROVIDE ACID RESISTING PORCELAIN ENAMEL INT r"
<br /> 0 7 NEW FLOOR SINK ZURN Z1900
<br /> ►- ° ° ° 318"MW.RADIUS FIXTURE ANCHORAGE ALUM ANTI SPLASH INT BOTTOM DOME a
<br /> a € : 1. Y"DIA.SIMPSON TITEN HD SCREW ANCHOR WITH 33/"EMBEDMENT, INSTALLED PER ICC REPORT STRAINER&NICKEL BRONZE TOP
<br /> a 3000 PS1 CONCRETE, ESR-2713,SPECIAL INSPECTION IS REQUIRED.
<br /> WIC RATION=0.45 2. AT ANCHOR THROUGH BASE,DRILL Yo"MAXIMUM OVERSIZE HOLE THROUGH BASE FOR ANCHOR,TYP.
<br /> TO MATCH EXISTINGMAX., NO SPECIAL OR IF PRE-MANUF.HOLES EXIST, INCREASE DIAMETER OF ANCHOR TO FIT HOLE BYE"MAX.,TYP.
<br /> INSPECTION REQUIRED 3. WHERE SEISMIC RESTRAINT CLIPS PROVIDED BY MANUFACTURER,USE CLIPS IN LIEU OF L3x3,TYP. z00clio
<br /> s TYPICAL CURB DETAIL FIXTURE ANCHORAGE TO SLAB DETAIL ,� z
<br /> Al SCALE:3"= 1'-0" Al SCALE:314"=1'-0"
<br /> V
<br /> S.
<br /> a
<br /> K
<br /> AREA OF WORK I`
<br /> o
<br /> Lu
<br /> c (v
<br /> (N)SLAB
<br /> g '` E ¢ i
<br /> '
<br /> EPDXY DOWELS @ 48"CC, CQ O R CD
<br /> C°
<br /> STAGGERED,TYP
<br /> - ® B C7
<br /> $ z
<br /> oa uj
<br /> cn a
<br /> TRENCH<24"WIDE z ® ® w
<br /> (SEE BELOW FOR INFO.,UNO) LL
<br /> 0 Lu o
<br /> ® o 0
<br /> LL
<br /> FLOOR SINK TO BE DRAIN FROM ❑
<br /> (E)SLAB (N)SLAB WI THICKNESS TO MATCH A Lu
<br /> INSTALLED FLUSH F RE ❑ o
<br /> EXISTING(4"MIN.), REINF.WI#4 @ wIFINISHED FLOOR IAIR GA
<br /> (n
<br /> #4x2'0"DOWELS @ 24"CC.EPDXY GROUT IN 4114 16"CC EA.WAY AT MID DEPTH o -
<br /> PLACE,TYP.SPECIAL INSPECTION NOT REQ'D. ol
<br /> (SIMPSON SEF-XP PER ICC REPORT ESR-2508) - --
<br /> a
<br /> ,3 n
<br /> __..
<br /> 3"WASTE PIPE O O N N ¢ 0
<br /> M
<br /> (MINIMUM) o d N a o Q g 0 m
<br /> TYP.UNO COMPACTED SLAB SUBGRADE TO O
<br /> MATCH CONDITIONS AT(E)BUILDING
<br /> NOTE:THIS DETAIL APPLIES TO CONVENTIONALLY REINFORCED SLABS-ON-GRADE ONLY. IT IS NOT <0 2>
<br /> APPLICABLE AT ELEVATED SLABS,POST-TENSIONED SLABS-ON-GRADE,STRUCTURAL MAT SLABS OR PROVIDE DEEP Q�
<br /> ® 8 o
<br /> 31 24
<br /> OTHER STRUCTURAL SLABS SUCH AS THOSE WITH GRADE BEAMS AND PILES OR PIER FOUNDATIONS, SEAL P-TRAP ® m ® fl o MANTECA, CA
<br /> CONTRACTOR TO CONFIRM SLAB-ON-GRADE CONDITION IN FIELD PRIOR TO DOING THE WORK AND t
<br /> NOTIFY ARCHITECT IF SLAB IS NOT ANON GRADE SLAB. ® 0
<br /> SLAB REPLACEMENT DETAIL s FLOOR SINK DETAIL
<br /> Al
<br /> SAFEWAY
<br /> SCALE:314"= 1'-0" Al SCALE:314"=1'-0"
<br /> ©©©
<br /> KEY PLAN Al
<br />
|