9 <br /> 1 2 3 4 4.2 5 6 7 8 8.1 10 11 GENERAL NOTES REVISIONS <br /> 1. THIS PLAN SHOWS GENERAL DEMOLITION WORK TO BE PERFORMED <br /> AND DOES NOT RELIEVE THE CONTRACTOR FROM OTHER DEMOLITION <br /> WORK REQUIRED TO PRODUCE THE BUILDING MODIFICATIONS SHOWN <br /> ON THE REMAINING CONTRACT DOCUMENTS. THE CONTRACTOR SHALL <br /> COORDINATE AND VERIFY THE ENTIRE DEMOLITION SCOPE WITH THE <br /> ARCHITECT OF RECORD AND WINCO CONSTRUCTION MANAGER. <br /> 2. FOR DEMOLITION WORK AS A RESULT OF EXISTING EQUIPMENT AND <br /> FIXTURE REMOVAL REFER TO PLUMBING, HVAC, ELECTRICAL, AND <br /> REFRIGERATION DRAWINGS FOR REMOVAL OF REQUIRED SYSTEMS. <br /> 3. EQUIPMENT ITEMS TO BE REMOVED ON THIS PLAN OR THE REMAINING <br /> CONTRACT DOCUMENTS SHALL REMAIN THE RESPONSIBILITY OF THE <br /> CONTRACTOR. THE CONTRACTOR SHALL PLACE THE EQUIPMENT IN <br /> STORAGE OR DISPOSE OF AS DIRECTED BY WINCO. (WASTE MATERIALS <br /> 0 0 o SHALL BE DISPOSED OF IN AN APPROVED MANNER.) <br /> P 0 P 4. CONTRACTOR SALVAGE ITEMS SHALL BE DISPOSED OF PROPERLY OFF <br /> SITE AND IN A EXPEDITIOUS MANNER. <br /> 5. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING <br /> 11 THE CONTRACTOR'S BEST SKILL AND ATTENTION. THE CONTRACTOR <br /> SHALL BE RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION <br /> 0 ❑ ° ° 0 MEANS, METHODS, TECHNIQUES, SEQUENCES, (UNLESS A SEQUENCE IS <br /> ° <br /> SPECIFIED BY THE OWNER OR CONTRACT DOCUMENTS). <br /> N 0 ° 6. SHORING OF STRUCTURAL FOUNDATION, STRUCTURES AND/OR ARCH. PROJECT NO. <br /> I ° <br /> TRENCHING REQUIRED TO COMPLETE THE WORK DESCRIBED IN THE 2006 <br /> CONSTRUCTION DOCUMENTS IS CONSIDERED A METHOD OR TECHNIQUE <br /> M.9 11 AND IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. IF A DRAWN <br /> ❑ REGULATORY AGENCY REQUIRES A LICENSED ARCHITECT OR D.M./K.B./N.C. <br /> ° ENGINEER TO SUPERVISE AND/OR APPROVE DRAWINGS FOR SHORING OF CHECKED <br /> o 0 o STRUCTURAL FOUNDATIONS, STRUCTURES, AND/OR TRENCHING IT IS THE C P <br /> ° RESPONSIBILITY OF THE CONTRACTOR TO CONTRACT WITH THE <br /> o l l ARCHITECT/ENGINEER. THE CONTRACTOR WILL PROVIDE THIS WORK SUBMITTAL DATES <br /> AS PART OF THE BASE BID. 06/12/20 <br /> 0 0 ° 7. DIMENSIONS SHOWN ON PLAN ARE FOR GENERAL REFERENCE BIDDING <br /> PURPOSES ONLY. DIMENSIONS ARE NOT EXACT AND ARE SHOWN ONLY <br /> TO PROVIDE A GENERAL IDEA OF EXTENT OF DEMOLITION REQUIRED. <br /> 8. PROTECT ALL EXISTING ITEMS THAT ARE TO REMAIN FROM DAMAGE OTB DATE <br /> DURING DEMOLITION AND CONSTRUCTION. <br /> 9. REMOVE ALL EXISTING WALL PLACED SIGNAGE AND PLACARDS IN MAIN <br /> ° HIEM _j <br /> SALES, ENTRY/EXIT, CUSTOMER SERVICE AND WHERE VISIBLE TO THE <br /> ° MAIN SALES. VERIFY PLACARD REMOVAL/REPLACEMENT WITH OWNER <br /> M - - - - M PRIOR TO REMOVAL. PATCH AND PREPARE ANY DAMAGED SURFACES <br /> °° ° p <br /> ° ° TO RECEIVE NEW FINISHES AS INDICATED IN DOCUMENTS. A o <br /> 10. REMOVE ALL AISLE MARKERS TYP. TO INCLUDE SUSPENDED x z o <br /> APPURTENANCES TO B.O. STRUCTURE. o o z F <br /> ° ° <br /> � zQ � w <br /> °° I I I I I I I 11. REMOVE ALL EXISTING WALL SIGNAGE AT THE MAIN SALES. PATCH AND <br /> -T ° ° - -° ° PREP ANY DAMAGED SURFACE TO RECEIVE NEW FINISHES AS INDICATED a a r u <br /> zx � 3 ozo <br /> 2 IN DOCUMENTS. <br /> 0.1 13. SEE SHEET AO.1 &Al I FOR RESTROOM DEMO AND FIXTURE RELOCATION. Q x <br /> 2' - 11" _ ° 1 14. EXISTING PALLET RACKS TO BE REMOVED SHALL BE SALVAGED TO <br /> ° ° <br /> 4 51-011 = REPLACE DAMAGED PALLET RACKS OR DAMAGED PARTS IN EXISTING <br /> ° 44 8 --- REMAINING LOCATIONS AS DIRECTED BY THE WINCO CONSTRUCTION w <br /> - - 15. EXISTING FLOOR SINKS AS OCCURS AT DEMOLITION OF REFRIGERATED <br /> ° I -` - CASES, COORDINATE WITH PLUMBING& REFRIGERATION. Q v w C a z <br /> K.3 -- -- WxWW � a <br /> O ❑❑❑ �� 35 3 24 �3aa� wz <br /> - 7 <br /> = Ell 3 22 <br /> 8 I = II 25 0 47 0 0 ® l7 9II 7 34 62 2cn <br /> I III �I� / m <br /> ❑ 20 o ❑ ° ° <br /> IF <br /> L I <br /> 40 ❑ ❑ ❑ \ 33 fAIA1lAltllAlTITQIAIQAIlfA1AI O N <br /> K - I = I r _ - - - - - - - - _ - - - - - � I --_-- 1 -= 1 --_=1---=- 1----= _-_- - - K c� <br /> 1- - -� -� - - -----T---�-- ----- ----- ----- ----- l I� -r - 1 --� --� - -T - <br /> ¢- - ° \ , ° M �� I� I KEYED NOTES �, <br /> � -� I - ��_� ----�_=�=� -----L-----�-----L - --- � �-y°I J 1 � �����-��-��_►����-►��_�-����-r�-���-rr���-rr -- 9 I O <br /> -- v v v v v v v v v v v v v v v v v v-_ <br /> 1. REMOVE ALL EXISTING CASE CORNER GUARDS TYP. THROUGHOUT W K' <br /> N/ v v � <br /> --- - - - --- 34 <br /> _ _ Off _ 00 <br /> < MAIN SALES. FILL HOLES IN EXISTING CONCRETE AS REQUIRED, Q <br /> I 3 3 27 � o <br /> 1 RE: SPEC. SECTION 033000, TYP. <br /> � O � <br /> ---------------------- 3 - II I 2. REMOVE EXISTING CART STOP, TYP. THROUGHOUT MAIN SALES. � <br /> I I � 22 4 12 42 43 22 10 10 � 2 � TYP. <br /> ° ° I i 7 3 3 �\ 3 3 �� - ----- r - -�____�______�______� _____�=====r=====r=== == �- I GRIND ANCHOR BOLTS FLUSH WITH SLAB, FILL HOLES AS REQUIRED, • W N <br /> �zj� � ��� � ` `'�`'� I =__ =1=====J1 II ___ !-___!-_____�-_____�-_____ __ ___�-_____�-_ = I =_= I I I RE: SPEC. SECTION 033000, TYP. � W <br /> - L <br /> /// �� /// �� /// �� /// r T 71 II I T T T T I T T T I 2 I 3. REMOVE EXISTING CASES &ALL RELATED ITEMS, TYP. TO INCLUDE li z <br /> /// //// /// /�// / �// ' / /// __ _____�_____� L =_ ___�===--4=----- =____+_____+_____+___ _� I CII I REMOVAL OF ALL EXISTING FLOOR SINKS@CASES. CAP &ABANDON Q W <br /> ° ° \y //// / //// / // //j/ / // /� / ------ 3I I EXISTING PLUMBING LINES BELOW SLAB IF NOT REUSED FOR NEW CASES, Z W cn p <br /> 17 22 / / / / / / �` RE. PO &P1. z 00 <br /> / / / / 23 13/ / / I 4. REMOVE/RELOCATE EXISTING GONDOLAS &ALL RELATED ITEMS TYP. v_ N <br /> // // // // // // // --- -- -- - 3 ----- -------- 2 I W ' W <br /> ¢ / // /// n ,\ /\ /\ /\ /\ /\ /\ ,\ ,\ /\ '\ /\ A ,� ,� ,� ,� ,� ,� A A N A ,� ,� ,� ,� ,� A A ,� ,� A ,\ FILL HOLES IN EXISTING CONCRETE AS REQUIRED, RE: SPEC. SECTION a <br /> A4, // /// /y - - �,�� ����- �>� �- � - - - - I < I I 033000, TYP. o O <br /> g // �` /// I I 3 I 5. REMOVE EXISTING WEDGE FILLER CABINET &ALL RELATED ITEMS. <br /> �� �� �� =1====== = :�:===== ===== == :=1==::=_ __ -�___ --L----__ I J w <br /> - � �r �/ �' I =- _=_ _ _ _ - - 6. REMOVE/RELOCATE EXISTING VENDOR WATER&ALL RELATED ITEMS, <br /> 22 I = r I I TYP. TO INCLUDE REMOVAL OF FLOOR SINK. CAP &ABANDON EXISTING Q <br /> I I 10 02 / PLUMBING LINES BELOW SLAB. RELOCATE WATER DISPENSER, RE: FP 1. <br /> 27 10 \ ---------------- \ I <� I 7. REMOVE/RELOCATE EXISTING WIDE SPAN RACKING&ALL RELATED Z <br /> �J 4 <br /> - TYP. -------------------- �I <br /> ----------------- 3 __ ITEMS. <br /> l <br /> - 0 9 9 2 `�I I 8. REMOVE EXISTING PALLET RACKING&ALL RELATED ITEMS, RE: AO- <br /> / - --- ----- -----�--- -r----- -----r---- r-- ------ ---- - - -- -- -- - - - T <br /> -- ---- -- --- - I GENERAL NOTE I4. <br /> --1-----1-----1-----1-----1-----1-----1-----�--- - - - - - - - - - - - - - �- - - - - - - - - - - <o o n - I9. REMOVE EXISTING PROTOCOL UNITS &ALL REFRIGERANT LINES, RE: R0.��sn -_ __ -�-� � '-�-�-� -�-�-E-�-� -�- - -�- -�-�- -1-j < 10. REMOVE/RELOCATE EXISTING FIXTURES &ALL RELATED ITEMS. ` <br /> o o ------- I DC7 <br /> o 4 < 11. REMOVE EXISTING DOCK BUMPERS & SEALS. � <br /> 12. REMOVE PORTION OF EXISTING WALL AS SHOWN, RE: A2 &A2.1. C-37 <br /> ---- 7ib <br /> 13. REMOVE EXISTING PLENUM WALL AND ALL RELATED ITEMS. FILL HOLES �, 01/31/21_b <br /> 9 �, - '��T--�T---T" T��� �� -i- IN EXISTING CONCRETE AS REQUIRED, RE: SPEC. SECTION 033000, TYP. AL <br /> DATU <br /> 3 ❑ ❑❑ � �_ �_ - - - - - - - - - - - - - - _ _ _ _ _ - - - - - - I I I 14. REMOVE EXISTING CHECKSTAND LANE LIGHTS, RE: A13-1. <br /> CAIq <br /> ❑❑ �� � � _ _ - - - - - - - - - - - - - - - -- - 1- -1 15. REMOVE RESTROOM SERVICE LIGHTS AND CALL BUTTONS. <br /> ❑❑ _______--------------- % I I 16. REMOVE EXISTING DAMAGED ACOUSTIC CEILING TILES, 50-100 COUNT AS <br /> -_- <br />