Laserfiche WebLink
Environmental Health Department <br /> COuT <br /> Erectness grows here. Time In: 12-30 pm <br /> Time Out: 1:00 om <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: SCHOONER LANDING APARTMENTS Date: 07/03/2018 <br /> Address: 7100 SHORELINE DR, STOCKTON 95219 <br /> Owner/Operator: PATMON SCHOONER LANDING LP Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Skimmer on the east side of the swimming pool was almost clogged with leaves, please ensure that <br /> skimmers are cleaned in order for proper circulation of water. Clean by today. In the same skimmer,there was no O-ring <br /> under the float valve assemble, replace within 1 week. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> #38 Filter Cleaning and Maintenance <br /> OBSERVATIONS:The difference between the influent and effluent gages on the swimming pool filter was greater than 10 <br /> psi indicating that the filter needs to be changed. Replace filter within a week, and ensure that difference between influent <br /> and effluent gages is less than 10 psi. <br /> CALCODE DESCRIPTION:All filters shall be maintained in accordance with manufacturer's specifications. (CBC 31238)Pressure gauge <br /> located on the filter shall be marked with the clean startup reading. (CBC 31258)Each filter vessel shall be provided with valves so that it <br /> can be isolated from the recirculation system for repairs and backwashing. (CBC 31288) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 60 gpm Chlorine: 5.2 ppm Temp: ° F <br /> Cyanuric acid: <30 ppm pH: 7.4 Combined chlorine: 0.2 ppm <br /> NOTES <br /> Influent pressure:16 psi <br /> Effluent pressure: 0 psi <br /> Filter for pool needs to be replaced. <br /> The rope that attaches to the circular flotation device was knotted up and hard to get free. Please organize the device and it's <br /> rope so that is easily accessible in an emergency. <br /> Replace O-ring in skimmer. <br /> The original document that contained the property managers signature was collected on the wrong report, that is why the <br /> signature does not show up here. <br /> FA0002553 PR0360552 SCO01 07/03/2018 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />