My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS (2)
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
4600
>
3600 - Recreational Health Program
>
PR0360045
>
WORK PLANS (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2020 4:52:57 PM
Creation date
9/24/2020 3:19:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
WORK PLANS
RECORD_ID
PR0360045
PE
3616
FACILITY_ID
FA0002104
FACILITY_NAME
SUSD-FRANKLIN HIGH SCHOOL
STREET_NUMBER
4600
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
14331006
CURRENT_STATUS
01
SITE_LOCATION
4600 FREMONT ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D ID ELEMENT BARRIER 2019 CBC UPGRADE REQUIREMENT <br /> KEYNOTE LEGEND <br /> 11 BOYS BATHING AND TOILET FACILITIES - BUILDING 'A' <br /> 1 PORTION OF EXISTING LOCKERS TO BE REMOVED FOR NEW ACCESSIBLE <br /> LOCKERS - SEE A4 FOR NEW LOCKER CONFIGURATIONS <br /> 11.1 ROUTE TO ENTRY DOOR 6" HIGH VERTICAL CURB OBSTRUCTS THE ACCESSIBLE 11 B-303.2 INSTALL A CURB RAMP-THIS IS ADDRESSED IN THE SITE <br /> 2 EXISTING LOCKERS TO REMAIN ROUTE TO THE RAISED SIDEWALK REQUIREMENTS, ITEM 6 <br /> 3 EXISTING CHANGING BENCH TO REMAIN <br /> 4 PORTION OF EXISTING CHANGING BENCH TO BE REMOVED 11.2 ENTRY DOOR DOOR REQUIRES MORE THAN 5-LBS. FORCE TO OPEN AND 11B-404.2.9 REPAIR OR REPLACE DOOR CLOSER TO ENSURE MAXIMUM <br /> CLOSES IN LESS THAN 5 SECONDS 5-LB PRESSURE AND CLOSING SPEED IS NOT FASTER THAN <br /> 5 CHANGING BENCH TO BE REMOVED ENTIRELY 5 SECONDS <br /> OPERATIONS AND HARDWARE EXTERIOR PULL-SIDE HARDWARE IS NOT ACCESSIBLE 11 B-404.2.7 REPLACE EXISTING DOOR PULL WITH AN ACCESSIBLE PULL <br /> 12.1 I <br /> HARDWARE. VERIFY W/ DISTRICT STANDARDS <br /> 11.3 TOILET COMPARTMENTS EXISTING TOILET COMPARTMENTS (3)ARE LESS THAN 3 11B-604.8.8.1 PROVIDE AT LEAST ONE COMPLIANT TOILET VERDE DESIGN <br /> FEET WIDE COMPARTMENT <br /> 11.4 LAVATORIES EXISTING LAVATORIES (3) HAVE ONLY 27" HIGH KNEE 11 B-306.3.1 PROVIDE AT LEAST ONE COMPLIANT LAVATORY- RAISE TO LANDSCAPE ARCHITECTURE <br /> CLEARANCE UNDER THE FRONT EDGE OF THE FIXTURES 11 B-306.3.3 HAVE 29" UNDER THE FRONT EDGE OF THE FIXTURE CIVIL ENGINEERING <br /> 11.5 URINALS A RAISED FLOOR DIRECTLY UNDER THE EXISTING 3 11 B-605.3.1 PROVIDE AT LEAST ONE COMPLIANT URINAL SPORT PLANNING& DESIGN <br /> URINALS BLOCKS THE REQUIRED "LEVEL" CLEAR FIXTURE 1843 Iron Point Rd #140 <br /> FLOOR SPACE Folsom,CA 95630 <br /> 11.6 LOCKER ROOM DRESSING AREA PROVIDE 5% (50-60 TOTAL (DISPERSED BY TYPE) tel:916.415.6554 <br /> ACCESSIBLE LOCKERS IN LOCKER ROOM fax:408.985.7260 <br /> ROUTE TO LOCKERS BENCHES BLOCK WHEELCHAIR ACCESS LEAVING AISLES 11 B-225.2.1 PROVIDE CLEAR FLOOR SPACE IN FRONT OF THE www.VerdeDesignlnc.com <br /> THAT RANGE FROM ONLY 20"TO 30"WIDE 11 B-811.2 ACCESSIBLE LOCKERS <br /> 11B-811.3 <br /> LOCKER HARDWARE THE APPROXIMATELY 1,200 INDIVIDUAL LOCKERS THAT ARE 11B-811.4 REPLACE NON-COMPLIANT LOCKERS WITH ONES WITH <br /> Y <br /> COMPRISED OF 3 DIFFERENT SIZES DO NOT HAVE ACCESSIBLE HARDWARE AND ACCESSIBLE REACH (48" STAMP <br /> r I ACCESSIBLE OPERATING HARDWARE A.F.F.)TO HARDWARE, SHELF AND GARMENT HOOKS <br /> �FNDSCgpe <br /> z 12.3 I BENCHES THERE ARE CURRENTLY NO ACCESSIBLE BENCHES 11 B-803.4 PROVIDE AT LEAST ONE ACCESSIBLE CHANGING BENCH ASBAGIN q� <br /> Y I I FOLLOWS: <br /> i I a. BENCHES THAT ARE 20"-24" IN DEPTH BY MINIMUM 48" `�'� No. 4089 <br /> IN LENGTH � �' <br /> b. A 30"X48" CLEAR FLOOR SPACE THAT IS POSITIONED AT <br /> 2 I THE END OF THE BENCH SEAT AND PARALLEL TO THE signature <br /> 12.1 I SHORT AXIS OF THE BENCH EXPIRATION DATE: <br /> n I I 11.7 SHOWERS APPROXIMATELY 40 SHOWERS ALL HAVE HIGH CONTROLS 11B-213.3.6 PROVIDE AT LEAST ONE ACCESSIBLE ROLL-IN SHOWER JULY 2021 <br /> AND NO FOLD-DOWN SEAT OR GRAB BARS ARE PROVIDED WITH COMPLIANT CONTROLS, GRAB BARS, FOLD-DOWN ��qTF <br /> p p GIRLS I SEAT, ETC. PER 11B-608 OF �AL� <br /> Y12.4 I 12 GIRLS BATHING AND TOILET FACILITIES - BUILDING 'A' <br /> Q I I CONSULTANT <br /> z I J O H N K R I S T E D J A <br /> LLIY <br /> 1F=n F=n 0==n 12.1 BUILDING ENTRANCE DOOR REQUIRES 9-LBS. FORCE TO OPEN 11B-404.2.9 REPAIR OR REPLACE THE DOOR CLOSER AS REQUIRED TO <br /> = I ENSURE MAXIMUM 5-LBS. OPENING PRESSURE <br /> 12.2 LOCKER ROOM ENTRANCE THE EXISTING DOOR HARDWARE IS A ROUND DOORKNOB 11B-404.2.7 REPLACE ROUND KNOB WITH COMPLIANT DOOR <br /> HARDWARE-VERIFY W/ DISTRICT STANDARDS <br /> y I I AHOLD OPEN DEVICE (KICKSTAND) OBSTRUCTS THE 11B-404.2.10 REMOVE THE KICKSTAND HOLD OPEN DEVICE ON THE <br /> GIRLS SHOWER ROOM REQUIRED SMOOTH SURFACE ON THE PUSH SIDE OF THE PUSH SIDE OF THE DOOR A R C H I T E C T <br /> Q I DOOR <br /> n I I DOOR REQUIRES 8-LBS. FORCE TO OPEN 11 B-404.2.9 REPAIR OR REPLACE DOOR CLOSER AS REQUIRED TO ARCHITECTURE ■ PLANNING <br /> n I 2 GIRLS LOCKER ROOM I ENSURE MAXIMUM 5-LBS. OPENING PRESSURE <br /> 1 12.3 TOILET COMPARTMENTS EXISTING TOILET COMPARTMENTS (3)ARE LESS THAN 3 11 B-604.8.8.1 PROVIDE AT LEAST ONE COMPLIANT TOILET <br /> i I FEET WIDE COMPARTMENT 6= &ttaft <br /> 3 12.6 I 12.4 LAVATORIES EXISTING LAVATORIES (3) HAVE ONLY 26-1/2" HIGH KNEE 11 B-306.3.1 PROVIDE AT LEAST ONE COMPLIANT LAVATORY- RAISE TO PI0=Nft CA <br /> CLEARANCE UNDER THE FRONT EDGE OF THE FIXTURES 11 B-306.3.3 HAVE 29" UNDER THE FRONT EDGE OF THE FIXTURE 0"d) -7 <br /> 2 AREA OF WORK 7&W fax <br /> 12.5 3 L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mill 12.5 LOCKER ROOM DRESSING AREA PROVIDE 5% (50-60 TOTAL (DISPERSED BY TYPE) <br /> ACCESSIBLE LOCKERS IN LOCKER ROOM <br /> n I 3I ROUTE TO LOCKERS BENCHES BLOCK WHEELCHAIR ACCESS LEAVING AISLES 11 B-225.2.1 PROVIDE CLEAR FLOOR SPACE IN FRONT OF THE _: �h'���''%,. <br /> 2 THAT RANGE FROM ONLY 20"TO 30"WIDE 11 B-811.2 ACCESSIBLE LOCKERS _ <• <br /> 3 11.7 I 11B-811.3 <br /> n I I LOCKER HARDWARE THE APPROXIMATELY 1,200 INDIVIDUAL LOCKERS THAT ARE 11B-811.4 REPLACE NON-COMPLIANT LOCKERS WITH ONES WITH 1 x <br /> COMPRISED OF 3 DIFFERENT SIZES DO NOT HAVE ACCESSIBLE HARDWARE AND ACCESSIBLE REACH (48" (-2229i <br /> Q <br /> 3 ACCESSIBLE OPERATING HARDWARE A.F.F.)TO HARDWARE, SHELF AND GARMENT HOOKS <br /> n I 2 I BENCHES THERE ARE CURRENTLY NO ACCESSIBLE BENCHES 11 B-803.4 PROVIDE AT LEAST ONE ACCESSIBLE CHANGING BENCH AS pF C <br /> FOLLOWS: <br /> z, 2 <br /> 11.5 I a. BENCHES THAT ARE 20"-24" IN DEPTH BY MINIMUM 48" <br /> BOYS RESTROOM I IN LENGTH <br /> r b. A 30"X48" CLEAR FLOOR SPACE THAT IS POSITIONED AT <br /> riI 2 11.4 I THE END OF THE BENCH SEAT AND PARALLEL TO THE <br /> SHORT AXIS OF THE BENCH <br /> n I BOYS SHOWER ROOM <br /> Z12.6 SHOWERS APPROXIMATELY 40 SHOWERS ALL HAVE HIGH CONTROLS 11B-213.3.6 PROVIDE AT LEAST ONE ACCESSIBLE ROLL-IN SHOWER <br /> I <br /> ri I AND NO FOLD-DOWN SEAT OR GRAB BARS ARE PROVIDED WITH COMPLIANT CONTROLS, GRAB BARS, FOLD-DOWN EYMAP <br /> 1 1 I SEAT, ETC. PER 11 B-608 <br /> = I 2 <br /> n <br /> I <br /> 2 2 2 2 I BUILDING ACCESSIBILITY REQUIREMENTS <br /> z <br /> 5 <br /> r I 3 <br /> I 2 <br /> 5 1 3 2 3 3 2 3 3 2 3 <br /> I I <br /> z 4 I SHEET TITLE <br /> I 2 <br /> y I 1 11.6 I BUILDING ACCESSIBILITY <br /> z � - - - - - - - - � � � � � - - - - - - - - - - - - - - - - - - - - - - � BOYS LOCKER ROOM <br /> ASSESSMENT PLAN <br /> z I 3 4 I CCESSIBILITY REQUIREMENT <br /> I <br /> 3 <br /> PROJECT NAME <br /> 2 <br /> > 4 <br /> 3 1 FRANKLIN HIGH SCHOOL <br /> > ATHLETIC IMPROVEMENTS <br /> _u 3 <br /> 11.2 <br /> 2 4 3 3 2 3 3 2 3 I <br /> Y <br /> z I I PROJECT ADDRESS <br /> Q <br /> z <br /> 4600 E. FREMONT ST. <br /> z I I <br /> n STOCKTON, CA 95215 <br /> _u <br /> r I <br /> r I I SUBMITTAL DATE <br /> r I <br /> DD/50% SUBMITTAL 03/06/202 <br /> Y <br /> 1 I y <br /> DSA 100% SUBMITTAL 05/01/202 <br /> Q <br /> n <br /> z <br /> z <br /> 3 <br /> y . <br /> Y O <br /> Q Z_ <br /> 7 <br /> Z Z <br /> jo NO. REVISIONS DATE <br /> nw <br /> 0 <br /> n0 Q <br /> yz <br /> 0 <br /> z� <br /> y <br /> nCn <br /> Y� <br /> 1 w <br /> ya <br /> Y <br /> Y Z <br /> H <br /> H <br /> < <br /> �O <br /> Z= <br /> H <br /> n� <br /> z <br /> Q� <br /> i> <br /> w <br /> Z) <br /> o DRAWN BY CHECKED BY <br /> Q� <br /> JK CS <br /> z <br /> yw <br /> U) DATE ISSUED SCALE <br /> z� <br /> ra 05/01 /2020 <br /> na BUILDING ACCESSIBILITY ASSESSMENT PLANPROJ. NO. <br /> o <br /> 1/8" <br /> = 1'-0" <br /> 1911000-1211 <br /> Z)z <br /> 0 <br /> Q a SHEET NO. <br /> y� <br /> Z�o <br /> 'O <br /> Q� F <br /> RAProject i es - <br /> PLOT DATE: 05-01-20 PLOTTED BY: JK Architect <br />
The URL can be used to link to this page
Your browser does not support the video tag.