My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1234
>
2300 - Underground Storage Tank Program
>
PR0516248
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/3/2024 1:20:32 PM
Creation date
9/25/2020 11:08:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0516248
PE
2361 - UST FACILITY
FACILITY_ID
FA0012532
FACILITY_NAME
CHEVRON STATION #209167
STREET_NUMBER
1234
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120016
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
1234 E YOSEMITE AVE MANTECA 95336
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN ) O A Q I N RECEIVED FEB 0 6 2019 Environmental Health Department <br /> �v O U N L. Y _. <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date : <br /> CHEVRON STATION #209167 1234 E YOSEMITE AVE , MANTECA February 06 , 2019 <br /> = UST System Observations <br /> 315 HSC 25291 (e) Water in secondary containment not removed, analyzed, and property disposed of (pre-Jul 2003) o V c R o COS <br /> 316 HSC 25290. 1 (c3), Secondary containment not constructed to prevent water Intrusion (after Jul 2003) o V a R o COS <br /> 25290.2(03) <br /> 317 CCR 2638, 2643(c)(1 ), Line leak detector (LLD) not installed o V a R o COS <br /> 2666(Q <br /> 318 CCR 2636(1)(2) Leak detector failed to detect a 3. 0 gallons per hour leak at 10 pounds per square inch o V a R o COS <br /> 319 CCR 2635, 2637. 1 , No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested o V ❑ R o COS <br /> 2665, 2712 <br /> 320 CCR 2635, 2637.2, Failure to comply with the installation, Inspection, or record keeping of the overfill prevention o V o R o COS <br /> 2665, 2712 <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden o V o R o COS <br /> 322 NSC 25281 .6(x) Unburied below grade emergency generator system failed to meet exemption status a V o R a COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status o V o R ❑ COS <br /> 324 CCR 2717. 1 (g) Tampered with red tag ❑ V o R o COS <br /> 325 CCR 2717. 1 (1) Deposited petroleum into a red tagged UST o V o R o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms a V o R o COS <br /> 327 CCR 2631 . 1 UST system not compatible with the substance stored o V o R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑ V o R o COS <br /> 329 HSC 25298 Failed to comply with all permanent closure requirements a V o R o COS <br /> 330 CCR 2636(91 2666(c), No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm ❑ V ❑ R o COS <br /> 2666(1) <br /> 331 CCR 2630(d) , 2641 (a) Liquid does not flow into the sump in the event of a leak (i.e., failure to remove test boot). o V o R a COS <br /> 332 CCR 2631 (b&d), Primary and/or secondary containment not constructed in accordance with the established standards o V o R o COS <br /> 2666(b&e) <br /> 333 CCR 26355 2636(b), Failure to comply with the cathodic protection system requirements o V o R a COS <br /> 2662, 2712 <br /> 334 CCR 2666(b)(2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair o V a R o COS <br /> 335 CCR 28301 2632, 2643 , Equipment or methods used to monitor the UST system are not certified by an independent third-party o V o R o COS <br /> 2644. 1 <br /> Singie-Walled Non=Pressurized Piping <br /> 401 CCR 2636(a)(3) , Suction piping not property sloped or Incorrectly located check valve o V o R o COS <br /> 2641 (b) <br /> 402 CCR 2643(d) No monitoring or record maintenance for single-walled conventional suction systems (pre=Jan 1984) . o V ❑ R o COS <br /> 403 CCR 2643(d) , 2661 (1) Failure to conduct 0.1 gph test for single-walled conventional suction systems (pre-Jan 1984) o V a R o COS <br /> 404 CCR 2643(6), 2661 (1) Biennial 0. 1 gph line integrity test for single-wailed gravity piping not performed (pre-Jan 1984) ❑ V ❑ R o COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑ V o R ❑ COS <br /> SUAflMARY OF UlQI.A IONS <br /> (CLAS8,t, %A% <br /> GL14 or MINOR - Notice.to Comply) <br /> Item # Remarks <br /> FA0012532 PR0516248 SC001 02/06/2019 <br /> EHD 2301 Rev. 09/28/2018 Page 3 of 4 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 T 209 468-3420 F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.