Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection S Repair Inspection ❑ 36 Month Inspection <br /> 1 . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment inspection <br /> 10151123 10-17-19 <br /> Business Name (Same as Facility Name or DBA-Doing Business As.) <br /> Sprint Stockton <br /> Business Site Address City ZIP Code <br /> 3807 Coronado Ave Stockton 195204 <br /> II , UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br /> Peter Jaure ui III 760 743 - 0518 Ext, <br /> Contractor/Tank Tester Ucense # ICC Certification # ICC Certification Expiration Date <br /> 708231 8195227 5-29-21 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> QPW 904559 <br /> 111. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method Used: S Manufacturer Guidelines (Specify) 0EW <br /> S Industry Code or Engineering Standard (Specify) PEI 1200 <br /> ❑ Engineered Method (Specify) <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages: <br /> Tank ID: (By lank number, stored product, etc.) Diesel <br /> What is the tank inside diameter? (Inches) 89.75% <br /> Is the fill piping secondarily contained? ❑ Yes ONO ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? ❑ Yes S No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> i <br /> veeder-root <br /> j Overfill Prevention Equipment Manufacturer(s) <br /> opw <br /> What is the overfill prevention equipment ® Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> response when activated? ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> (Check all that apptyj ® AN Alarm ❑ AN Alarm ❑ AN Atertn <br /> ❑ A/V Alarm <br /> Are flow restrictors installed on vent piping? ❑ Yes S No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention 752803/8 <br /> set to activate? (inches from bottom of tank.) <br /> What is the percent capacity of the tank at which 90, 95 <br /> the overfill prevention equipment activates? <br /> Is the overfill prevention in proper operating S Yes ❑ Yes ❑ Yes =ed <br /> condition to respond when the substance ❑ No ❑ No ❑ No <br /> reaches the appropriate level? (Specify in section V.) (Specify in section V.) (Speciy in secti2V.) V J <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results S Pass [I Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> All items marked TaiPmust be explained in this section. Any additional comments may also be provided here. <br /> A new OPW71 S041 OCT Valve was installed and set to shut off at 95% <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations, title 23, division 3, <br /> chapter 16, section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature /.p <br /> If the facility has more components than Orts forth accommodates, additional copies of this page may be attached. <br /> 3 CERS = California Errvironmental Reporting System ID = kkntificatkx% UST = UnderWound storage tank, ICC = International Code Cosnck AN = Audible and visual <br /> i <br />