My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LATHROP
>
1137
>
2300 - Underground Storage Tank Program
>
PR0530093
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/8/2022 4:00:29 PM
Creation date
9/28/2020 7:53:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0530093
PE
2351
FACILITY_ID
FA0019793
FACILITY_NAME
CRUISERS MANTECA #29
STREET_NUMBER
1137
Direction
W
STREET_NAME
LATHROP
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
19724002
CURRENT_STATUS
01
SITE_LOCATION
1137 W LATHROP RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br />COUNTY— <br />Environmental <br />OU 1TY <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />CRUISERS MANTECA #29 <br />1137 W LATHROP RD, MANTECA <br />August 24, 2020 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR- Notice to Comply) <br />Item # <br />Remarks <br />306 <br />CCR 2630(d), 2641(a) Monitoring equipment is not installed or maintained to detect a leak at the earliest <br />opportunity. <br />OBSERVATION: The 91 STP sensor was raised approximately one inches off the lowest point of the sump [OR <br />LOCATED ON TOP OF THE SADDLE OF THE TANK OR WRONG SIDE, ETC] and not located to detect a leak at <br />the earliest opportunity. <br />REGULATION GUIDANCE: Monitoring equipment shall be maintained to be able to detect a leak at the earliest <br />possible opportunity. <br />CORRECTIVE ACTION: The sensor was relocated to the lowest point of the sump by the service technician. <br />Ensure that all monitoring equipment is maintained and located to detect a leak at the earliest opportunity. <br />This is a Class II violation. <br />319 <br />CCR 2635, 2637.1, 2665, 2712 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be <br />tested. <br />OBSERVATION: The 87 and 91 spill container failed when tested. <br />REGULATION GUIDANCE: All spill containers shall have a minimum capacity of five gallons and be capable of <br />containing a spill or overfill until it is detected or cleaned up. <br />CORRECTIVE ACTION: Immediately contact a properly licensed, trained, and certified contractor to repair or <br />replace the spill container under permit and inspection of the EHD. <br />This is a minor violation. <br />Overall Inspection Comments: <br />On site for the monitoring system certification. The testing was not witnessed in its entirety. Looked inside all <br />sumps and UDCs. Verified proper sensor locations. Verified spill bucket 5 gallon capacity <br />A checklist was provided; a complete report will be provided at the time of paperwork inspection. <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br />of having them sign. Starting September 1, 2018, all in -office CERS help will be provided at EHD hourly rate <br />($152). To schedule an appointment, please call (209) 468-3420. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received by: Date: August 24, 2020 <br />Inspector: <br />Inspector Phone: <br />Printed Name and Title: <br />PAUL NSO, EH Specialist <br />(209) 468-3432 <br />Rachel Shook, Manager <br />FA0019793 PR0530093 SCO01 08/24/2020 <br />EHD 23-01 Rev. 8/11/2020 Page 4 of 4 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.