My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3304
>
2300 - Underground Storage Tank Program
>
PR0516354
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2021 9:36:33 AM
Creation date
9/28/2020 8:26:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0516354
PE
2361
FACILITY_ID
FA0012437
FACILITY_NAME
CHEVRON 352324
STREET_NUMBER
3304
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
07120013
CURRENT_STATUS
01
SITE_LOCATION
3304 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN <br /> J D �� I Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON 352324 3304 W HAMMER LN, STOCKTON June 18, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 202 CCR 2715(c)(3), 2715(c)(4) Failure to maintain the"Facility Employee Training Certificate"on-site(after October 1, <br /> 2018). <br /> On the Facility Employee Training Certificate dated 1/16/19, employee Judith Miranda was noted to assume <br /> responsibility as a facility employee on 11/6/18 but she was not initially trained until 1/16/19.All site employees must <br /> be trained prior to taking responsibility as a facility employee if after October 1,2018, or within 30 days of hire if prior <br /> to October 1, 2018. The Facility Employee Training Certificate shall contain accurate information for all employees <br /> trained. Update the Facility Employee Training Certificate to contain the accurate information and submit a copy of <br /> the updated form to the EHD. <br /> This is a minor violation. <br /> 204 CCR 2712(i)Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be <br /> accessible on site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> 205 CCR 2712(i), 2634(e)Failure to submit a current UST Response Plan and have it available onsite. <br /> An approved copy of the response plan was not available for inspection. A copy of these plans shall be accessible <br /> on site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> A designated operator inspection was performed on 3/15/2019 and the next inspection was performed on <br /> 4/21/2019, 37 days later. The designated operator visual inspections shall be conducted within 30 days or less of <br /> the previous inspection. Ensure that all designated operator inspections are performed within the required time <br /> frames. <br /> The following was observed on the designated operator's monthly inspection reports: <br /> -Secondary containment testing was incorrectly noted, correct test date is 7/12/18. <br /> During the visual inspection,the designated operator shall check all required testing and maintenance for the UST <br /> system have been completed and shall check all required items on the report. Ensure that designed operators <br /> performing visual inspections at this facility are including all of the required information on the reports. <br /> This is a minor violation. <br /> FA0012437 PR0516354 SCO01 06/18/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.