My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 3:11:20 PM
Creation date
9/28/2020 9:19:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
FACILITY_NAME
H&S Energy Products,#3034
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Overfill Prevention Equipment Inspection Report <br /> 6 . OVERFILL PREVENTION EQUIPMENT DETAILS <br /> Tank ID (one OPE per column) 87 91 Diesel <br /> Are both vent and tank riser piping ® Yes © Yes © Yes 0 Yes <br /> secondarily contained ? 0 No 0 No El No © No <br /> OPE Model 61 SO 61 SO 61 SO <br /> What is the OPE response when Shut off F] Shut off 0 Shut off [n Shut off <br /> activated ? Flow Flow Flow Flow <br /> (Check all that apply.) M Restricts © Restricts r] Restricts r] Restricts <br /> Flow Flow Flow Flow <br /> ® Audible 0 Audible ® Audible ® Audible <br /> Alarm Alarm Alarm Alarm <br /> Visual ® Visual ® Visual ® Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent piping © Yes * El Yes * ® Yes * © Yes * <br /> that may interfere with the OPE operation ? ®✓ No ®✓ No 0 No ® No <br /> At what level in the tank is the OPE set to 86 85 . 5 86 <br /> activate ? (Inches from bottom of tank <br /> What is the percent capacity of the tank at 94 . 7 % 94 . 3 % 94 . 7 % <br /> which the OPE activates ? <br /> Is the OPE in proper operating condition to ©✓ Yes ✓© Yes * IM Yes * ® Yes * <br /> respond when the stored substance r] No ® No ® No ® No <br /> reaches the designated regulatory level ? <br /> 7 . SUMMARY OF TESTING RESULTS <br /> OPE Inspection Results P Pass El Pass 0 Pass ® Pass <br /> r] Fail © Fail ® Fail ® Fail <br /> 8 . COMMENTS <br /> Describe all answers marked 'Wo " or "Fail" and proposed remedy. <br /> List all monitoring equipment either replaced or repaired. <br /> * Mark here if: <br /> ® Flow restrictors interfere with overfill prevention and equipment repairs required . <br /> Additional copies of this page may be attached. <br /> Attach tank chart(s) , measurements, calculations, and In - Tank Setup report(s) <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.