My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2802
>
2300 - Underground Storage Tank Program
>
PR0516736
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2021 11:36:54 AM
Creation date
9/28/2020 9:28:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0516736
PE
2361
FACILITY_ID
FA0012764
FACILITY_NAME
SAFEWAY FUEL CENTER #1769
STREET_NUMBER
2802
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2802 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action ❑ Installation Inspection ❑ Repair Inspection ® 36 Month Inspection <br /> I . FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10156809 11 /22/19 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Safeway <br /> Business Site Address City ZIP Code <br /> 2802 Country Club Blvd , Stockton 95204 <br /> II . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br /> Brian McPheely {916 ) 649-8670 <br /> Contractor / Tank Tester License # IGC Certification # ICC Certification Expiration Date <br /> 485184 8822062 1119! 19 <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> 1014303708 / B36745 <br /> III . OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑ Manufacturer Guidelines (Specify) : <br /> Used : <br /> ® Industry Code or Engineering Standard (Specify) : Veeder Root <br /> ❑ Engineered Method (Specify) : <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages <br /> TANK ID : (By tank number, stored product, etc.) T1 , 87 T2 : 91 T3 : Diesel <br /> What is the tank inside diameter? (Inches) 119 . 5 119 . 5 119 . 5 <br /> Is the fill piping secondarily contained? Q Yes ❑ No © Yes ❑ No © Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? ❑ Yes © No ❑ Yes ® No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) Veeder Root Veeder Root Veeder Root <br /> What is the overfill prevention equipment response ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ❑ Restricts Flow El Restricts Flow ❑ Restricts Flow ❑ Restricts Flow <br /> ® AIV Alarm ® AN Alarm ® AN Alarm ❑ AN Alarm <br /> Are flow restrictors installed on vent piping? ❑ Yes © No ❑ Yes © No ❑ Yes ® No ❑ Yes ❑ No <br /> At what level in the tank is the overfill prevention set <br /> to activate? (inches from bottom of tank.) 100 . 5 10015 100 . 5 <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 90% 90 % 90% <br /> Is the overfill prevention in proper operating condition ® Yes ® Yes ® Yes ❑ Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No (Specify in V) [:3 No (Specify in V) [3 No (Specify in V) ❑ No (Specify in V) <br /> IV, SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ® Pass ❑ Fail ® Pass ❑ Fail ® Pass ❑ Fail ❑ Pass ❑ Fail <br /> V, COMMENTS <br /> Any items marked "Fail' must be explained in this section. Any additional comments may also be provided here. <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations , Title 23 , <br /> Division 3 , Chapter 16 , Section 2637 . 2 and all the information contained herein is accurate. <br /> UST Service Technician Signature �_� <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = California Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = International Code Council, AN = Audible and Visual <br />
The URL can be used to link to this page
Your browser does not support the video tag.