My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2802
>
2300 - Underground Storage Tank Program
>
PR0516736
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2021 11:36:54 AM
Creation date
9/28/2020 9:28:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0516736
PE
2361
FACILITY_ID
FA0012764
FACILITY_NAME
SAFEWAY FUEL CENTER #1769
STREET_NUMBER
2802
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2802 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax; (209)468-3433 Web:www.sjaov.orcI/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SAFEWAY FUEL CENTER#1769 2802 COUNTRY CLUB BLVD STOCKTON January 22 2019 <br /> Other Violations <br /> 2010 1 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms are not current in CERS. <br /> -The tank forms for all three tanks incorrectly list both audible/visual alarm and fill tube shut off valve (flapper) as the <br /> the overfill prevention. No flappers were observed on site. <br /> -The tank forms list single-walled vent and vapor recover piping. Double walled fiberglass piping was observed in the fill <br /> sumps. It could not be determined if the piping was vent or vapor recovery. <br /> -The diesel tank form states there is no vapor recovery piping. The diesel tank was previously a gasoline tank. <br /> Confirm that the accurate information is submitted. <br /> Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br /> update the required information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 109 CCR 2637(a-d), 2712 Failed to test secondary containment, or failed to maintain test records for 36 months. <br /> UDCs 3/4 and 9/10 were installed on 7/20/17 and six month testing was due by January 2018. Testing was <br /> completed on 4/10/18, three months past due. Secondary containment testing is required six months after installation <br /> and at least every 36 months after. Ensure all testing is completed within the required time frames in the future. <br /> This is a Class II violation. <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br /> An inspection was last done on January 22, 2018 and an inspection report was issued identifying information to be <br /> submitted to bring this site into compliance. This information was required to be submitted by February 21, 2018. <br /> The complete information was received on 3/21/18, one month past due. An operator that receives an inspection <br /> report shall have 30 days to submit a written response that includes a statement documenting corrective actions taken <br /> or proposing corrective actions which will be taken. Ensure that a written response documenting corrective actions <br /> taken or proposed is submitted within 30 days of receiving an inspection report. <br /> This is a Class II violation. <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm. <br /> According to the technician, the diesel fill sump sensor passed initial testing, but then continued to go into and out of <br /> alarm for the remainder of the inspection. All monitoring equipment shall be maintained to activate an audible and <br /> visual alarm or stop the flow of product at the dispenser when it detects a leak. The sensor was replaced and retested <br /> during the inspection. A"UST Retrofit Verification with Inspector Already Onsite"form has been completed and <br /> provided to the operator and contractor. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> FA0012764 PR0516736 SCO01 01/22/2019 <br /> EHD 23-01 Rev.09/22/16 Page 4 Of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.