Laserfiche WebLink
A J OA U I Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MARCH AND BIANCHI INC 1 1916 E MARCH LN, STOCKTON November 19, 2020 <br /> Single-Walled Non-Pressurized Piping <br /> 404 CCR 2643(,),2661(f) Failure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair(pre-1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 1 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2632(d)(1), 2634(d) Failure to have an approved UST Monitoring Plan. <br /> OBSERVATION: The monitoring plan is not current and/or not approved by the EHD. The monitoring plan for all <br /> tanks under tank monitoring and piping monitoring incorrectly state the monitoring panel model as TLS 350 plus <br /> and TLS 350R , the panel model on site is TLS 350. <br /> REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting <br /> System (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the <br /> EHD. <br /> This is a minor violation. <br /> 105 CCR 2632(d)(2), 2634(e) Failure to have an approved UST Response Plan. <br /> OBSERVATION: Section V of the response plan was left blank. <br /> REGULATION GUIDANCE: The complete response plan must be uploaded to the California Environmental <br /> Reporting System (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, upload the completed form, and submit for review by the EHD. <br /> This is a minor violation. <br /> 106 CCR 2632(d), 2641(h) Failure to submit and maintain a current facility plot plan/site map. <br /> OBSERVATION: An accurate UST Monitoring Site Plan was not submitted. The site plan submitted does not <br /> contain locations of the annular sensors, vacuum monitoring and piping. <br /> REGULATION GUIDANCE: Asite plan must be submitted identifying the locations where monitoring will be <br /> performed. The site plan must show the general layout of tanks and piping and clearly identify locations of the <br /> following equipment, if installed: 1) monitoring system control panels; 2) in-tank liquid level probes (if used for leak <br /> detection); 3) devices monitoring tank annular spaces or vault; 4) devices monitoring product piping; 5) devices <br /> monitoring fill piping; 6) devices monitoring vent piping; 7)devices monitoring vapor recovery piping; 8) devices <br /> monitoring vent/transition sumps; 9) devices monitoring under-dispenser containment; 10) line leak detectors; and <br /> 11) devices monitoring any other secondary containment areas. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br /> http://cers.calepa.ca.gov/and upload a copy of the UST Monitoring Site Plan. <br /> This is a minor violation. <br /> FA0018792 PR0527728 SCO01 11/19/2020 <br /> EHD 23-01 Rev.9/16/2020 Page 4 of 9 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />