Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PACIFIC ETHANOL STOCKTON LLC 3028 NAVY DR, STOCKTON December 06, 2018 <br /> Item# Remarks <br /> 101 CCR 66262.12 Managed a hazardous waste without an identification number. <br /> This facility's hazardous waste ID number is inactive. A hazardous waste generator shall not treat, store, dispose <br /> of,transport or offer for transportation, hazardous waste without a hazardous waste ID number. Go to the DTSC <br /> web site http://www.dtsc.ca.gov/IDManifest/PERMHWID.cfm for the form to reactivate the ID number. Immediately <br /> reactivate your state ID number and submit evidence to the EHD. <br /> This is a minor violation. <br /> 102 CCR 66262.11 Failed to determine if a waste is a hazardous waste. <br /> One red 5 gallon plastic bucket containing trash was observed near the used oil storage area. The manager was <br /> not sure what the contents were. <br /> One white 5 gallon plastic bucket containing lubricant was observed near the turbine. The manager was not sure if <br /> the lubricant was a waste or not. <br /> Any person who generates a waste shall determine if the waste is a hazardous waste. Immediately make a <br /> hazardous waste determination for the wastes, and manage them according the Title 22 hazardous waste <br /> regulations. Submit a statement and supporting documentation explaining how the contents were managed. <br /> This is a repeat violation, Class II. <br /> 103 CCR 66262.40(c) Failed to retain hazardous waste determination including waste analysis on site for 3 years. <br /> On 9/13/2017, Manganese(III)Oxide, defoamer, and asphalt petroleum were disposed of as non-hazardous waste. <br /> According to the manager, each waste was profiled for hazardous waste determination. The profile information was <br /> not available for review during the inspection. A generator shall make a hazardous waste determination and keep a <br /> record of any test results,waste analyses, or other determinations made in accordance with hazardous waste <br /> regulations for at least three years from the date that the waste was last disposed of. Immediately locate a copy of <br /> the waste analysis conducted for the above listed wastes and submit a copy to the EHD. If a copy is unavailable, <br /> immediately make a hazardous waste determination and begin managing the above listed wastes under Title 22 <br /> hazardous waste regulations. <br /> This is a minor violation. <br /> 104 CCR 66262.34(d)(2)No modified contingency plan. <br /> The emergency coordinator information needs to be updated. The plan currently lists Joe Teubner as the primary <br /> coordinator. According to the manager, Jeff Usinger is the new primary coordinator. There must be at least one <br /> emergency coordinator on site or on call to coordinate emergency response measures, and the following <br /> information must be posted by a phone: the name and phone number of the emergency coordinator; location of fire <br /> extinguishers, spill control equipment, and if present,fire alarm; and the phone number of the fire department, <br /> unless the facility has a direct alarm. Immediately update the contingency plan and send in the updated information <br /> to the EHD for review. <br /> This is a repeat violation, Class II. <br /> FA0019299 PR0528381 SCO01 12/06/2018 <br /> EHD 22-01 Rev.09/22/16 Page 4 of 8 Small Quantity Hazardous Waste Generator OIR <br />