Laserfiche WebLink
Hazardous Waste Tank System <br /> Title 22 Assessment per CCR Title 22 October <br /> Premier Dodge of Tracy,3460 Naglee Drive, Tracy, CA 95304 2014 <br /> Seismic Calculation <br /> Seismic Calculation - Tank: Used Oil Tank <br /> Rectangular, Vertical Closed Top, Flat Bottom, Double Wailed <br /> Material of Construction: steel <br /> Shell Height, in 36,50 <br /> - Shell Length, in 6811 <br /> Working Volume, gal 252.00 <br /> S.G. of contents 0—.9—5 <br /> Tank Wall Thickness, in 0.12 <br /> Total Weight of Tank and Contents, lbs 2849,00 <br /> Overturning Moment Arm, in 20.00 <br /> Resisting Moment Arm, in 18.00 <br /> Sds 0.89 <br /> Importance Factor 1.00 <br /> Fp, ASCE 7-10, 15.4-2 760.68 <br /> Overturning Moment inlbf 15213.66 <br /> Resistinq Moment, inlbf 51282.00 <br /> Overturning Safety Factor- No Tension 3.37 <br /> Shear Strength of Anchor. Lbs 2620.00 <br /> # of Anchors 4.00 <br /> Factor of Safety for Shear 13.78 <br /> Seismic/Anchoring findings: The tank as dE signed and operated and the <br /> containment area in which it is located arjadt-jo tely anchored and are <br /> seismically sound. Initials <br /> Strandberg Associates 1(866) 388-0404 'ohn@strandberaassociates.com 11 <br />