Hazardous Waste Tank System October <br /> Title 22 Assessment per CCR Title 22 <br /> Premier Dodge of Tracy,3460 Naglee Drive, Tracy, CA 95304 2014 <br /> Seismic Calculation <br /> Seismic Calculation - Used Antifreeze Tank <br /> Rectan ular with integral secondary containment <br /> Material of Construction: steel <br /> Shell Height, in 36.50 <br /> Shell Length, in 5411 1 <br /> -Working Volume, gal 216.00 <br /> S.G. of contents 1.05 <br /> Tank Wall Thickness, in 0.11 <br /> Total Weight of Tank and Contents, lbs 2561.00 <br /> Overturning Moment Arm, in 19.00 <br /> Resisting Moment Arm, in 18.00 <br /> Sds 0.89 <br /> Importance Factor 1.00 <br /> Fp, ASCE 7:10, 15.4-2 6$3.79 <br /> Overturning Moment inlbf 12991.95 <br /> Resisting Moment, inlbf 46098.00 <br /> Overturning Safety Factor- No Tension 3.95 <br /> Shear Strength of Anchor. Lbs 2620.00 <br /> # of Anchors 4.00 <br /> Factor of Safety for Shear 15.33 <br /> Seismic/Anchoring findings: The tank a signed and operated and the <br /> containment area in which it is located are uately anchored and are <br /> seismically sound. Initials: <br /> Strandberg Associates 1(866) 388-0404 iohn(cDstrandbergassociates.com 19 <br />