My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELLIOTT
>
21001
>
2300 - Underground Storage Tank Program
>
PR0504060
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2020 11:03:59 AM
Creation date
9/30/2020 10:48:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0504060
PE
2332
FACILITY_ID
FA0010533
FACILITY_NAME
LOCKEFORD PLANT MATERIAL CNTR
STREET_NUMBER
21001
Direction
N
STREET_NAME
ELLIOTT
STREET_TYPE
RD
City
LOCKEFORD
Zip
95237
APN
05121038
CURRENT_STATUS
04
SITE_LOCATION
21001 N ELLIOTT RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AJNIFIED PROGRAM CONSOLIDATED FOI TANK: <br /> PR#: <br /> FAC#: <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> VL PIPING CONSTRUCTION(Check all that apply) Page 3 of 3 <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ❑ 1.PRESSURE [12.SUCTION ❑ 3.GRAVITY 458 ❑ 1.PRESSURE ❑ 2.SUCTION ❑ 3.GRAVITY 45" <br /> CONSTRUCTION [-11.SINGLE WALL ❑3.LINED TRENCH ❑ 99.OTHER 460 ❑ 1.SINGLE WALL ❑ 95.UNKNOWN 462 <br /> ❑2.DOUBLE WALL E395.UNKNOWN ❑ 2.DOUBLE WALL ❑ 99.OTHER <br /> MANUFACTURER 461 MANUFACTURER 46' <br /> ❑ 1.BARE STEEL ❑6.FRP COMPATIBLE W 100%METHANOL ❑ 1.BARE STEEL ❑ 6.FRP COMPATIBLE w/100%METHANOL <br /> ❑ 2.STAINLESS STEEL ❑7.GALVANIZED STEEL ❑ 2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL <br /> ❑PLASTIC COMPATIBLE W/CONTENTS ❑ 95.UNKNOWN ❑ PLASTIC COMPATIBLE W/CONTENTS ❑95.UNKNOWN <br /> ❑4.FIBERGLASS [18.FLEXIBLE(HDPE) ❑ 99.OTHER ❑ 4.FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑99.OTHER <br /> ❑ 5.STEEL W/COATING ❑9.CATHODIC PROTECTION 464 ❑ 5.STEEL W/COATING ❑ 9.CATHODIC PROTECTION 46i <br /> VII.PIPING LEAK DETECTION(Check at that apply)(A description of the monitoring program shall be submitted to the local agency.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF <br /> FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND <br /> VISUAL ALARMS. VISUAL ALARMS. <br /> ❑2.MONTHLY 0.2 GPH TEST ❑ 2.MONTHLY 0.2 GPH TEST ❑3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 4.DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑ 5.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIEAL PIPING ❑ 5.DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INTEGRITY TEST(0.1 GPH) ❑ 6.TRIENNIAL INTEGRITY TEST(0.I GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): <br /> ❑ 7.SELF MONITORING <br /> ❑ 7.SELF MONITORING <br /> GRAVITY FLOW <br /> ❑9.BIENNIAL INTEGRITY TEST(0.1)GPH GRAVITY FLOW(Check all that apply): <br /> ❑ 8.DAILY VISUAL MONITORING <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Check one) <br /> ❑a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ c. NO AUTO PUMP SHUT OFF <br /> ❑ 11.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR ❑ 11 AUTOMATIC LEAK DETECTOR <br /> RESTRICTION <br /> ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Chats all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF* ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW <br /> ❑SHUT OFF OR RESTRICTION SHUT OFF OR RESTRICTION <br /> ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17.DAILY VISUAL CHECK ❑ 17.DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT ❑ 1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑4.DAILY VISUAL CHECK <br /> DATE INSTALLED 469 ❑2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5.TRENCH LINER/MONITORING <br /> ❑ 3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ❑ 6.NONE <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS 46j <br /> IX.OWNER/OPERATOR SIGNATURE <br /> 1 certify that the information provided herein is true and accurate to the best of my kno%iedge. <br /> SIGNATURE OF OWNER/OPERATOR DATE 470 <br /> NAME OF OWNER/OPERATOR(print) TITLE OF OWNERIOPERATOR <br /> 471 472 <br /> Permit Number(For local use onlc) 473 Permit App-d(For local use onh) 474 Pemhit Expiration Daze(For local use only) 475 <br /> UPCF(12/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.