My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1800
>
2300 - Underground Storage Tank Program
>
PR0231036
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/6/2024 2:23:12 PM
Creation date
10/2/2020 9:22:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231036
PE
2361 - UST FACILITY
FACILITY_ID
FA0003761
FACILITY_NAME
ST JOSEPHS HOSPITAL
STREET_NUMBER
1800
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12718044
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
1800 N CALIFORNIA ST STOCKTON 95204
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
California - ss Underground s <br /> Facility/Site <br /> i <br /> 105EPHS HOSPITAL U5T Tank 9/CERS Tank CERS 1D <br /> ID 10181391 <br /> 1800 N CALIFORNIA ST TA0103603/ <br /> 10181391-001 <br /> TOCKTON,CA 95204 Tank Info:Installed Date:1/1/199212:00:00 AM-Tank Use:Other•Tank Contents:Diesel-I <br /> Type Of Tank:Double Walf-Pi 3ng Construction:Double-walled <br /> Pipe Monitoring is Performed Using the Following Method(s) <br /> es Continuous Monitoring of Piping Secondary Containment <br /> Piping Secondary Containment Panel Manufacturer Leak Sensor Manufacturer <br /> Dry O/C Tanks Owens Corning <br /> Panel Model is Leak Sensor Model 9 <br /> 5800118 OCLS <br /> Leak Alarm Triggers Automatic Pump Shutdown <br /> Failure/Disconnect Triggers Pump Shutdown <br /> Mechanical Line Leak Detector Performs 3 GPH Leak Test <br /> MLLD Manufacturer MLLD Model <br /> Electronic Line Leak Detector Performs 3 GPH Leak Test <br /> ELLD Manufacturer ELLD Programmed in-Line Testing ELLD Triggers Automatic Pump Shutdown <br /> LLD Model ELLD Failure/Disconnect Triggers Automatic Shutdown <br /> Pipeline Integrity Testing Yes Visual Pipeline Monitoring <br /> Pipeline integrity Testing Frequency Visual Pipeline Monitoring Frequency <br /> Daily <br /> Suction Piping Meets Exemption Criteria <br /> No Regulated Piping Per Health and Safety Code,Division 20,Chapter 6.7 Is Connected To The Tank System <br /> Other Pipeline Monitoring <br /> Under Dispenser Containment(UDC)Monitoring <br /> DC Monitoring Detection of Leak into UDC Triggers Audible and Visual Alarms <br /> No Dispensers <br /> UDC Leak Alarm Triggers Automatic Pump Shutdown <br /> DC Panel Manufacturer <br /> Failure/Disconnection of UDC Monitoring System Triggers Automatic Pump Shutdown <br /> DC Panel Model rl <br /> UDC Monitoring Stops Flaw of Product at Dispenser <br /> DC Leak Sensor Manufacturer <br /> UDC Construction <br /> ❑C Leak Sensor Model <br /> UDC Secondary Containment Monitoring <br /> Leak Within Secondary Containment of UDC Causes Audible and Visual Alarms <br /> Periodic System Testing <br /> ELD Testing <br /> Yes Secondary Containment Testing <br /> Yes Spill Bucket Testing <br /> Printed on 10/29/2020 4:48 PM <br />
The URL can be used to link to this page
Your browser does not support the video tag.