Laserfiche WebLink
�U'" SAN 10AQUINa <br /> Environmental Health Department <br /> r� ; ; -- COUNTY Wayne Fox , REHS , Interim Director <br /> cgiIFOR��p Greutness grows here . PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> August 12 , 2020 <br /> Marshall Swift <br /> MCR Engineering <br /> 1242 Dupont Court <br /> Manteca , California 95336 <br /> RE : Onsite Wastewater Treatment System <br /> 14600 Austin Road , Manteca <br /> APN : 206 - 100 -05 , SR0082149 <br /> The San Joaquin County Environmental Health Department ( EHD ) has received and reviewed the plan check <br /> for the Onsite Wastewater Treatment System ( OWTS ) Design dated May 18 , 2020 , THE Septic Design <br /> Analysis dated July 6 , 2020 , multiple revisions and correspondence by phone and by emails , and the final <br /> revision language and diagram dated August 12 , 2020 , all prepared by MCR Engineering ( MCR) for the above <br /> noted location . MCR proposed the following : <br /> 1 ) System A which consists of the two existing septic tanks ( a 4 , 500 -gallon septic tank installed under <br /> Permit No . 71 -239) and an approximately 5 , 000 -gallon septic tank installed before 1970 ( no permit <br /> records found ) to be connected to a new filter bed measuring 52 feet by 100 feet , <br /> 2 ) Replacement of the pump/panel/wiring in the lift station in the 5 , 000 -gallon septic tank , <br /> 3 ) System B which consists of a new 2 , 500-gallon septic tank and a filter bed measuring 15 feet by 100 <br /> feet . <br /> 4 ) Disconnection of the existing leach field where a new building is to be located . A separate existing <br /> leach field by the restroom is to remain . <br /> 5 ) Destruction of a 2 , 400-gallon septic tank located on the northeast corner ( about 150 south of the <br /> existing well ; tank was installed under Permit No . 77 -430 ) . The septic tank is currently serving a small <br /> office which has been planned for demolition . <br /> EHD approves the OWTS Design with the following comments : <br /> 1 . Obtain septic permit for System A , and a separate permit for System B <br /> 2 . There shall be audio / visual alarm at the lift station after replacement of the pump and panel . <br /> 3 . OWTS shall be installed according to the work plan . <br /> 4 . Any septic tank to be abandoned shall be destroyed under permit . <br /> If you have any questions please contact Jeffrey Wong , Lead Senior Registered Environmental Health <br /> Specialist , at jwong@sjgov . org or (209) 468- 0335 . <br /> 1 <br /> Mic ael Kith , REHS <br /> Program Coordinator <br /> CC : Manteca USD , New Haven Elementary , PO Box 32 , Manteca , CA 95336 <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468 -3420 1 F 209 464 -0138 1 www . sjgov . org /ehd <br />