i <br /> i <br /> FLOOR AND WALL OPENINGS <br /> i <br /> An opening means a gap or void 34 inches or more by 18 inches or more through which an employee can fall <br /> to a lower level, <br /> An opening in a floor(walkinghvorking)surface 6 feet or more above lower levels must be protected from an <br /> employee falling by use of a guardrail system,safety net system,or a cover. <br /> When a cover is placed over a floor opening,the cover must be capable of supporting,without failure,at least <br /> twice the weight of employees, equipment, and other materials that may be imposed on the cover at any one <br /> time. All covers must be secured when installed so as to prevent accidental displacement by the wind, <br /> equipment, or employees. All covers must be color-coded or marked with the `opening', "DO NOT <br /> REMOVE"to provide warning of the hazard. <br /> An opening in a wall where the outside bottom edge of the opening is 6 feet or more above lower levels and <br /> (lie inside bottom edge is less than 39 inches above the floor(walking/working)surface the opening must be <br /> protected from an employee falling by the use of a guardrail system, a safety net system, or a personal fall- ' <br /> arrest system. <br /> l <br /> f <br /> k <br /> i <br /> i <br /> i <br /> I <br /> I <br /> i <br /> i <br />