Laserfiche WebLink
SEP 17 2020 <br />INTRODUCTION ENVIRONMENTAL HEALTH <br />DEPARTMENT <br />This report issues my findings regarding the Nitrate Loading Study (NLS) conducted for the <br />referenced project. A Soil Suitability Study for this project was completed by the engineering firm <br />CTE Cal, Inc. and has been submitted concurrently with this NLS. These Studies were required <br />because of regulations enacted by the San Joaquin County Environmental Health Department <br />(EHD) to ensure nitrate loading standards are adequately assessed when new improvements occur <br />on a subject Parcel. Specifically, concerns regarding nitrate loading could potentially occur when <br />additional residential unit dwellings are constructed on comparatively small parcels. This project <br />consists of three residential units on the 5.72 acre subject Parcel. The proposed residential <br />structure to be built can be considered the primary unit with the address of 5388 Fig Avenue. The <br />proposed pool cabana/game room associated with this primary unit has been submitted under a <br />separate building permit. The existing second unit dwelling has the address of 5400 Fig Avenue. <br />The last unit dwelling on the property is to be considered Farm Labor Housing, which has the <br />address of 5412 Fig Avenue. <br />Within the text of this Report, Bolded Section (§) numbers are referenced at the beginning of an <br />applicable Paragraph(s), or Appendix that corresponds with the EHD Nitrate Loading Study <br />Requirements Checklist. Other portions of text may also apply to other sections of the Checklist. <br />The following summarizes the investigative parameters included to complete this report: <br />• Soil chemical testing was conducted on soil samples retrieved from a backhoe test pit in the <br />proposed location of the new leachfield area. Physical testing of the soil sample included <br />texture particle size analysis for sand, silt and clay content, and chemical testing analyses <br />for the constituents that influence nitrate loading. <br />• The nitrate loading to the on-site soils in combination with nitrate impact potential to the <br />underlying groundwater from percolating effluent was quantified through generally <br />accepted calculations. An assessment of the characteristics of the on-site soils was made to <br />discuss the mitigation of nitrate impact. <br />• A well water sample was retrieved from the existing on-site domestic well for analysis of <br />nitrate, the agrichemical DBCP, and alkalinity. <br />SOIL INFORMATION <br />NLS§ 1.1. The UC Davis Soil Map indicates the Map Unit Name soil type is 85% Tinnin loamy <br />coarse sand (#255), with the remaining percentages as Delhi, Manteca, Veritas, Honcut and Timor <br />loamy sands. The retrieved soil samples referenced in the attached texture analysis reveals the on- <br />site soils at the 3 ft and 6 ft depths consist of loamy sand and at 9 ft the soil is a sand. The sand, <br />silt and clay percentages are illustrated on the Test Report. <br />Page -1- <br />Chesney Consulting <br />