Laserfiche WebLink
Percolation Test <br /> A shallow percolation test was conducted near the proposed septic disposal areas of <br /> the Site. The soil boring discussed above was used for the percolation test hole. <br /> Percolation test procedures conformed to San Joaquin County Environmental Health <br /> Department policy. <br /> Preparation and Presaturation of Percolation Test Holes <br /> After the boring was advanced by hand auger and the soil logged, the test hole was <br /> completed for the percolation testing. Approximately two inches of pea gravel were <br /> placed in the bottom of the open soil boring, followed by a 2.0-inch diameter PVC pipe <br /> with perforations on the bottom. Pea gravel was then used to backfill a few inches of <br /> the annular space. <br /> Live Oak presaturated the percolation test hole approximately 24 hours prior to the <br /> percolation testing. The hole was filled with water to a height of 12 inches above the <br /> bottom of the boring for the presaturation. On the day of testing, the hole was found to <br /> be intact and dry. <br /> Percolation Test Procedure <br /> Live Oak conducted the percolation test for the boring on June 17, 2020. Percolation <br /> test procedures conformed to San Joaquin County Environmental Health Department <br /> policy. Due to the soil type observed, a standard four-hour test was selected. Water <br /> level measurements were taken every 30 minutes during this four-hour period. <br /> Sukhreet Kaur, Registered Environmental Health Specialist at the San Joaquin County <br /> Environmental Health Department, observed the percolation test. <br /> An electronic well sounder with a depth accuracy of 1/100th foot was utilized for the <br /> water level measurements. The water level was measured against a fixed reference <br /> point on the well casing. Measurements were recorded on the data sheet in decimal <br /> feet. When necessary after measuring the water level, the hole was refilled with water <br /> to a level of approximately six inches above the bottom of the hole. <br /> Percolation Test Results <br /> The completed percolation test form is included in Appendix 3 of this report. The form <br /> was signed by Ms. Kaur and indicates a percolation rate for the hole based on the final <br /> water drop observed. <br /> Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. <br /> LOGE 20-44 Page 5 <br />