My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINNE
>
1728
>
2800 - Aboveground Petroleum Storage Program
>
PR0540694
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2021 8:48:08 AM
Creation date
11/18/2020 10:59:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0540694
PE
2832
FACILITY_ID
FA0009536
FACILITY_NAME
CONCRETE INC
STREET_NUMBER
1728
STREET_NAME
LINNE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25311027
CURRENT_STATUS
01
SITE_LOCATION
1728 LINNE RD
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
16 <br />Are all valves free of leaks, corrosion and other <br />damage? Follow manufacturers' instructions for <br />regular maintenance of these items. Check the <br />following and verify (as applicable): <br />Anti-siphon valve <br />Check valve <br />Gate valve <br />Pressure regulator valve <br />Expansion relief valve <br />Solenoid valve <br />Fire valve <br />Shear valve <br />EYes E No EN/A <br />OYes ONo EN/A <br />OYes E No EN/A <br />OYes ONo EN/A <br />ElYes EINo EN/A <br />OYes EINo EN/A <br />OYes EINo EN/A <br />17 Are strainers and filters clean and in good condition? Yes • No • N/A <br />Insulated Tanks <br />18 <br />Free of missing insulation? <br />Insulation free of visible signs of damage? <br />Insulation adequately protected from water intrusion? <br />Yes M No • N/A <br />19 Insulation free of noticeable areas of moisture? Yes • No • N/A <br />20 Insulation free of mold? II Yes • No • N/A <br />21 Free of visible signs of coating failure? Yes • No • N/A <br />Tank / Piping Release Detection <br />22 Is inventory control being performed and documented <br />if required? Yes • No M N/A <br />23 Is release detection being performed and documented <br />if required? Yes • No • N/A <br />Other Equipment <br />24 Are electrical wiring and boxes in good condition? Yes III No • N/A <br />25 <br />Has the cathodic protection system on <br />the tank been tested as required by <br />the designing engineer? <br />Yes • No M N/A <br />Annual Checklist Page 3 of 4
The URL can be used to link to this page
Your browser does not support the video tag.