Laserfiche WebLink
SANJOAQUIN <br />­-COUNTY- <br />ZMEMEMME9s a MMAM <br />i} `} <br />" ' } Abo�eg$o�in� PetroleumtorageAct Ins}pectiontlepo r" <br />Facility Name: <br />CONCRETE INC <br />Facility Address: Date: <br />1728 LINNE RD, TRACY November 17, 2020 <br />eke 4 <br />lee�t <br />ffFM r1 M QU411ibij, ,auUy,TterWe l� ll`14 1� ,ae% �;�;llllel <br />t, <br />95205 � T <br />209 468-3420 � F 209 464-0138 � <br />404 <br />CFR 112.6(a)(3)(It) <br />No 2CT for bulk containers, or mobile storage containers not located to prevent discharge <br />❑ V <br />o R <br />o COS <br />405 <br />CFR 112.6(a)(3)(iii) <br />Overfill prevention for containers not provided, not described in Plan, or tested <br />o V <br />❑ R <br />o COS <br />�..: <br />" „r'. ,, ll, 1 1 11I„ 4 Qua7fied,ac�lity Trer 11 ; /,e <br />el 11% <br />el lee <br />ell <br />501 <br />CFR 112.6(a)(1), <br />112.6(b) <br />Tier II Qualified Facility Plan not certified by the owner ora PE, as required <br />o V <br />o R <br />❑ COS <br />502 <br />CFR 112.6(b)(2) <br />Tier II Qualified Facility Plan technical amendment not certified by the owner or a PE <br />in V <br />o R <br />o COS <br />503 <br />CFR 112.6(b)(3), <br />112.6(b)(4) <br />Failure to have a PE certify in writing alternative measures fora Tier II Qualified Facility <br />❑ V <br />c R <br />o COS <br />504 <br />CFR 112.6(b)(4)(i) <br />Failure of ownerto assure that a PE makes all required attestations in a Tier II Plan <br />c V <br />m R <br />c COS <br />,. / <br />.; , eheral;Re'qu�reme�Ys for`SPCGPIarts..w: ,,,., . , �,:„ <br />. <br />rellr <br />,; <br />. <br />601 <br />CFR 112.7 <br />Failure of Plan to fulfill basic requirements including a cross-referencing section <br />o V <br />o R <br />o COS <br />602 <br />CFR 112.7(a)(2) <br />Plan failed to discuss equivalent environmental protection, if applicable <br />in V <br />o R <br />o COS <br />603 <br />CFR 112.7(a)(3) <br />Failed to adequately describe the physical layout of the facility in the Plan <br />o V <br />o R <br />c COS <br />604 <br />CFR 112.7(a)(3)(i) <br />Plan failed to include oil type and storage capacity for each container <br />o V <br />o R <br />o COS <br />605 <br />CFR 112.7(a)(3)(ii) <br />Plan failed to adequately discuss discharge prevention measures, including routine handling <br />o V <br />o R <br />c COS <br />606 <br />CFR 112.7(a)(3)(iii) <br />Plan failed to adequately discuss facility drainage or drainage controls <br />o V <br />o R <br />o COS <br />607 <br />CFR 112.7(a)(3)(iv) <br />Plan failed to include countermeasures for discharge discovery, response and cleanup <br />c V <br />c R <br />in COS <br />608 <br />CFR 112.7(a)(3)(v) <br />Plan failed to address disposal methods for recovered materials <br />❑ V <br />❑ R <br />❑ COS <br />609 <br />CFR 112.7(a)(3vi), <br />112.7(a4) <br />Plan failed to adequately contain procedures for reporting a discharge <br />in V <br />o R <br />o COS <br />610 <br />CFR 112.7(a)(5) <br />Discharge procedures are not adequately addressed if the facility has no response plan <br />o V <br />o R <br />o COS <br />611 <br />CFR 112.7(b) <br />Plan failed to include a description of potential equipment failure or provide equivalence <br />❑ V <br />❑ R <br />o COS <br />612 <br />CFR 112.7(c) <br />Plan failed to discuss general secondary containment, equipment, or structures to prevent discharge <br />o V <br />o R <br />o COS <br />613 <br />CFR 112.7(c) <br />Failure to provide appropriate secondary containment, diversionary structures or equipment <br />❑ V <br />o R <br />❑ COS <br />614 <br />CFR 112.7(d) <br />PE certified Plan failed to explain impracticability of containment/diversionary structures <br />❑ V <br />❑ R <br />❑ COS <br />615 <br />CFR 112.7(d) <br />Failure to perform integrity and leak testing when claiming secondary containment impracticability <br />❑ V <br />❑ R <br />❑ COS <br />616 <br />CFR 112.7(d)(1) <br />Failure to prepare an oil spill contingency plan when claiming impracticability of structures <br />o V <br />o R <br />o COS <br />617 <br />CFR 112.7(4)(2) <br />No written commitment of manpower, equipment, and materials to control and remove oil discharge <br />o V <br />o R <br />o COS <br />618 <br />CFR 112.7(e), 112.8(c) <br />6 <br />Failure to keep written records of procedures, inspections, and tests for at least three years <br />o V <br />❑ R <br />❑ COS <br />619 <br />CFR 112.7(f)(1) <br />Failed to train personnel on all discharge prevention details listed in this section <br />o V <br />o R <br />c COS <br />620 <br />CFR 112.7(f)(2) <br />Failed to designate a person accountable for discharge prevention - <br />❑ V <br />❑ R <br />❑ COS <br />621 <br />CFR 112.7(f)(1) <br />Failure to include in the SPCC Plan an adequate description of employee training <br />o V <br />o R <br />o COS <br />622 <br />CFR 112.7(f)(3) <br />Failure to conduct complete annual discharge prevention briefings for oil -handling personnel <br />o V <br />in R <br />o COS <br />623 <br />CFR 112.7(g) <br />Plan failed to address security of site and valves, lock outitag out, and lighting <br />o V <br />o R <br />o COS <br />624 <br />CFR 112.7(g) <br />Facility failed to implement security measures listed in the SPCC Plan (lighting, security, etc.) <br />o V <br />m R <br />o COS <br />625 <br />CFR 112.7(h) <br />Plan failed to adequately discuss facility tank car and tank truck loading/unloading rack <br />in V <br />o R <br />o COS <br />FA0009536 PR0540694 SC001 11/17/2020 <br />EHD 28-01 Rev. 9/16/2020 <br />Page 2 <br />of 5 <br />Aboveground Petroleum Storage Act OR <br />1868 E. Hazelton Avenue � <br />Stockton, <br />California <br />95205 � T <br />209 468-3420 � F 209 464-0138 � <br />vnvw.sjgov.org/EHD <br />