My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LINNE
>
1728
>
2800 - Aboveground Petroleum Storage Program
>
PR0540694
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2021 8:48:08 AM
Creation date
11/18/2020 10:59:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0540694
PE
2832
FACILITY_ID
FA0009536
FACILITY_NAME
CONCRETE INC
STREET_NUMBER
1728
STREET_NAME
LINNE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25311027
CURRENT_STATUS
01
SITE_LOCATION
1728 LINNE RD
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
15.5 Internal Heating Coils- 40 CFR 112.8 �c)(7) <br />The bulk storage tanks do not have internal heating coils. <br />1111 <br />Prior to delivering diesel fuel to the above ground storage tank, fhe fuel delivery eontractor <br />determines the amount o€ fuel to be delivered by gauging 'the tank. The delivery contractor <br />remains in the immediate vicinity of the 'tank during fuel transfer and meters and monitors the <br />amount of fuel delivered. The contractor can immediately respond to a potential overfill <br />situation by shutting down the delivery truck's pumping equipment. The receiving diesel fuel <br />tank does not include an automatic shut off -device that impedes and stops fuel delivery as the <br />tank nears 95% of its listed capacity. <br />Product is delivered at a controlled rate and continuously monitored to prevent overfilling. <br />Table 3B <br />TANK INTEGRITY TESTING PROGRAM <br />KRC TRACY PLANT <br />Tank ID <br />Integrity <br />Tank Configuration <br />Comments <br />Details of Testing <br />Testing <br />Standard <br />101000- <br />STI <br />Double walled steel <br />Exterior of containment <br />Periodic visual inspections <br />gallon <br />SP001-6 <br />tank, horizontal, <br />shell is visible <br />per SP001 testing <br />diesel fuel <br />cylindrical STI <br />Lack of manway <br />standard, formal external <br />tank <br />Fireguard <br />prevents interior <br />inspections every 20 years <br />configuration. Tank <br />inspection, <br />not in contact with the <br />Adequate vent relief <br />ground. Tank <br />Wall thicknessl/4" <br />conforms to UL 2085 <br />Excellent protective <br />coating <br />500 -gallon <br />STI <br />Double walled steel <br />Exterior of containment <br />Periodic visual inspections <br />diesel fuel <br />SP001-6 <br />tank, horizontal, <br />shell is visible <br />per SP001 testing <br />tank <br />cylindrical STI <br />Lack of manway <br />standard <br />Fireguard <br />prevents interior <br />configuration. Tank <br />inspection. <br />not in contact with the <br />Adequate vent relief <br />ground. Tank <br />Wall thicknessl/4" <br />conforms to UL 2085 <br />Excellent protective <br />coating <br />1 @ 200 <br />Single walled steel <br />PG&E Owned <br />Visual <br />gallon pad <br />tank. Tank is not in <br />mounted. <br />contact with the <br />transformer <br />ground. <br />15.5 Internal Heating Coils- 40 CFR 112.8 �c)(7) <br />The bulk storage tanks do not have internal heating coils. <br />1111 <br />Prior to delivering diesel fuel to the above ground storage tank, fhe fuel delivery eontractor <br />determines the amount o€ fuel to be delivered by gauging 'the tank. The delivery contractor <br />remains in the immediate vicinity of the 'tank during fuel transfer and meters and monitors the <br />amount of fuel delivered. The contractor can immediately respond to a potential overfill <br />situation by shutting down the delivery truck's pumping equipment. The receiving diesel fuel <br />tank does not include an automatic shut off -device that impedes and stops fuel delivery as the <br />tank nears 95% of its listed capacity. <br />Product is delivered at a controlled rate and continuously monitored to prevent overfilling. <br />
The URL can be used to link to this page
Your browser does not support the video tag.