PLUMBING SYMBOLS: NOTES= <br /> O1 CONNECT NEW SINK INTO EXISTING WASTE AND VENT STUB IN <br /> CW DOMESTIC COLD WATER WALL. <br /> HW DOMESTIC HOT WATER O CONNECT NEW WATER CLOSET INTO EXISTING WASTE STUB IN <br /> FLOOR. <br /> HWR ••• DOMESTIC HOT WATER RETURN 0 42" BY 12" BY 12" DEEP CONCRETE BASIN. REF <br /> STRUCTURAL. <br /> SS WASTE PIPING <br /> O4 2" WASTE UP AND 1.5" VENT DOWN TO WASHING MACHINE <br /> GW GREASE WASTE CONNECTION BOX. <br /> 5 2" WASTE UP AND 1.5" VENT DOWN SERVING FLOOR DRAIN. Architect of Record: <br /> RD STORM DRAIN O Mariah B. Meyer <br /> O6 SAW CUT FLOOR AND CONNECT 2" WASTE INTO EXISTING 4" 8131 Metcalf Avenue <br /> -------- VENT PIPING SANITARY SEWER MAIN. BACKFILL AND MATCH EXISTING Suite 300 <br /> SS/V COMBINATION WASTE & VENT FLOOR FINISH. Overland Park,KS 66204 <br /> O7 CONNECT 2" VENT INTO EXISTING VENT THRU ROOF. www.brrarch.com <br /> D DRAIN O 3" WASTE UP AND 2" VENT DOWN SERVING FLOOR SINK. Tel:913-262-9095 <br /> Fax:913-262-9044 <br /> G NATURAL GAS < 2" WASTE UP AND 1.5" VENT DOWN SERVING SINK. <br /> SHUT-OFF VALVE 10 EDGE OF GREASE INTERCEPTOR SHALL BE A MINIMUM OF 18" <br /> FROM THE OUTSIDE FACE OF BRICK. COORDINATE LOCATION <br /> CHECK VALVE WITH GAS PIPE AND METER RELOCATION. <br /> a� BALANCING VALVE W/ PRESSURE PORTS 11 4" ROOF DRAIN DOWN IN WALL. D I SCHARGE ABOVE GRADE d w <br /> WITH DOWNSPOUT NOZZLE. co �U� z ui w <br /> oz— <br /> s SHOCK ABSORBER 12 REMOVE 4" ROOF DRAINAGE I NAGE P IPE I N WALL. EXTEND NEW 4" W o a ��LL o w o <br /> DRAIN ABOVE CEILING AS SHOWN. 'x=z LL X W a _ o 0 <br /> a--~m LL=XW_X �w�U <br /> WH WALL HYDRANT 13 CUT AND PATCH FLOOR WITH EXISTING FLOOR FINISHES. p w w 3 ¢g 0=w a o'i z m <br /> LL au~iQ)zZOazO>B }a <br /> FFCO FLUSH FLOOR CLEANOUT 14 PROVIDE STAINLESS STEEL L INT SOCK STRAINER ON WASHING Z a p a w a ¢w z X v 2 <br /> 11 MACHINE DRAIN D I SCHARGE FOR THE PURPOSE OF 0 �u_w o z)0 a Z W w W 0 w z <br /> 3 • ❑FGCO FLUSH GRADE CLEANOUT I NTERCEPT I NG LINE AND SMALL DEBRIS FROM THE WASHER 1- 0 w a�'r°o o w 2 X cD o a <br /> 30 O DRAIN. ENSURE THAT IT IS ACCESSIBLE FOR CLEANING; Q Z 0-of 2 0 P cn W >w z or:0 <br /> �I CO CLEANOUT PROVIDE ACCESS PANEL AS NEEDED. afZ.z q'0 a w z a w(w <br /> —4 F47 :) I I + + z 15 EXTEND 4" WASTE LINE BELOW GRADE AS SHOWN. RECONNECT °z o a o o w a o❑ o o� <br /> El ELBOW U P WITH SHUT-OFF VALVE EXISTING 3" VENT P IPE I N WALL. r 0 ov o m a 0 o w a¢r a a of <br /> 3 ( I 4 AFID 0 I CQ 1 1 O / ELBOW DOWN WITH SHUT-OFF VALVE 16 TERM I NATE CONDENSATE DRAIN OVER FLOOR SINK WITH A I R <br /> G� 11 1 GAP AND INSTALL TRAP UPSTREAM OF FLOOR SINK. SEAL <br /> ETR 21 COOLER/ FREEZER WALL PENETRATIONS AIR—TIGHT AND <br /> 1 __ I 2 �+ TEE UP WITH SHUT-OFF VALVE PROVIDE ESCUTCHEON AT WALL PENETRATION. <br /> 0 I 4" A R 1 ® _ 3"SS I I I ��, WITHATRAP w Y 17 PROVIDE RUNNING TRAP FOR INTERIOR CONDENSATE HEATERS CONSULTANT LOGO <br /> 30 4 I _ GUARD INSERT TEE DOWN WITH SHUT-OFF VALVE O RUNN I NG BETWEEN FREEZER AND COOLER. PROVIDE TRAP IN <br /> y - ] CAP COOLER UPSTREAM OF EVAPORATOR CONNECTION. <br /> 18 ROUTE 1", COPPER TUBING FOR COOLER/FREEZER CONDENSTAE <br /> 2" FS TO FLOOR SINK; PROVIDE AND INSTALL HEAT TAPE ON <br /> FLOOR SINK, TYPE & SIZE CONDENSATE LINES EXPOSED IN FREEZER AREA. COORDINATE <br /> i ———E}———————2"V————— 21 WITH ELECTRICAL CONTRACTOR FOR POWER. <br /> _* 3"ss4) �Q 4 4 RB ROOF DRAIN, TYPE & SIZE <br /> ETR 2 / 19 APPROXIMATE LOCATION OF 6" SANITARY WASTE MAIN BELOW r m <br /> GRADE. k I t <br /> 15 CO 3"SS(E) PLUMBING FIXTURE TYPE MARK ©0 REROUTE EXISTING CONDENSATE SERVING COOLER EVAPORATOR <br /> TO FLOOR DRAIN AS SHOWN. TERMINATE WITH AIR GAP. engineering consultants <br /> a ® WATER CLOSET & TYPE 21 PROVIDE NEW STRAINER FOR SHOWER DRAIN. 650 E.Algonquin Road I suite 250 Schaumburg,IL s01�3 <br /> T:913.322.1400:www.rtmec.com <br /> 13 22 3" WASTE UP AND 3" VENT DOWN SERVING WASHING MACHINE <br /> 2 ❑1 ® COUNTER TOP LAVATORY & TYPE O <br /> \ �R CONNECTION BOX. <br /> 1 d SHOWER HEADS & TYPE <br /> 1 ❑ GENERAL NOTES. W <br /> 0 Z <br /> ;RD 4" 1 w 21 1. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH THE i <br /> 2019 EDITION OF THE CALIFORNIA PLUMBING CODE.2 0 <br /> ?CONTRACTOR SHALL FIELD VERIFY ALL EXISTING U <br /> —J O CONSTRUCTION PRIOR TO SUBMITTING HIS BID. NO EXTRAS U) <br /> 21 WILL BE PAID DUE TO UNANTICIPATED EXISTING <br /> CONDITIONS. LU W <br /> 1 <br /> ETR 2 2. CONTRACTOR SHALL SCHEDULE AND EXECUTE ALL WORK WITH = <br /> REGARD TO THE OWNER'S USE OF THE BUILDING. <br /> OW <br /> / • 3. PLANS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED. W p <br /> REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS. Ce) LL <br /> < W <br /> 4. ALL FIXTURES ARE PROVIDED WITH STANDARD TRAP AND \` (N O_ co <br /> o <br /> CLEANOUT (NOT SHOWN). U CN p <br /> O5. ALL WORK SHALL BE PROPERLY TESTED, BALANCED, CLEANED, Z <br /> 21 AND DISINFECTED. O O_ <br /> Z W I- <br /> 6. ALL WASTE PIPING 3" AND SMALLER SHALL BE SLOPED AT <br /> 1/4" PER FT. PIPING LARGER THAN 3" SHALL BE SLOPED AT O W Of p <br /> \ 1/8" PER FT. Q <br /> /ETR / 7. PROVIDE ASSE 1072 BARRIER TYPE TRAP SEAL PROTECTION 0 0 <br /> / FOR ALL FLOOR DRAINS AND FLOOR SINKS EQUIVALENT TO <br /> — 1 SURE SEAL. <br /> Clio o <br /> j // O 5 O 8 co <br /> CONNECTIONGENERAL BOTHOTTH THE CTOR LCUSTOMER L BE PAND IEMPLOYEE BLE FOR TLAUN RYHE L <br /> O MACHINES. THIS INCLUDES ALL WATER, SEWER, ELECTRICAL, <br /> L o� AND EXHAUST CONNECTIONS. <br /> o <br /> 4"SS(E) 4"SS(E) 6"SS(E) 9. FLOOR SINK TYPE "A" SHALL BE WATTS MODEL FS-740-1— <br /> 4 SS E <br /> 150—FC ASME A112.21.1M, 12"X12" SQUARE LACQUERED CAST W <br /> IRON BODY WITH INTEGRAL SEEPAGE PAN, EPDXY COATED p0 <br /> i KSG INTERIOR, 8" DEEP SUMP, ALUMINUM DOME STRAINTER, <br /> ° 6 CLAMP COLLAR, HALF GRATE, AND SATIN NICKEL—BRONZE <br /> STRAINTER. PROVIDE A P—TRAP FOR ALL FLOOR SINKS. Z <br /> 10. FLOOR DRAIN TYPE "A" SHALL BE WATTS MODEL FD12—R-6R— 0 <br /> 1g HNB ASME A112.21.1M, ON GRADE PVC TWO PIECE BODY WITH <br /> C ADJUSTABLE 6" DIAMETRER SATIN NICKEL BRONZE STRAINER. <br /> 11. ROOF DRAIN TYPE "A" SHALL BE WATTS MODEL RD-300 <br /> FS COATED CAST IRON BODY, BOTTOM OUTLET, NO—HUB ROOF ISSUE BLOCK <br /> r A DRAIN WITH CAST OR DUCTILE IRON DOME, MEMBRANE CLAMP, <br /> ADJUSTABLE EXTENSION, SUMP REC I EVER AND UNDERDECK <br /> CLAMP. NO. DATE DESCRIPTION <br /> w <br /> vii 12. ROOF DRAIN TYPE "B" SHALL BE WATTS MODEL RD-300—R <br /> C fn COATED CAST IRON BODY, BOTTOM OUTLET, NO—HUB, 2" <br /> WATER DAM OVERFLOW ROOF DRAIN WITH CAST OR DUCTILE <br /> J I C I IRON DOME, MEMBRANE CLAMP, ADJUSTABLE EXTENSION, SUMP <br /> RECIEVER AND UNDERDECK CLAMP. <br /> O <br /> O 7 <br /> I 11 <br /> CHECKED BY: BJK <br /> IT 1T� 4 PRD DRAWN BY: JHF <br /> 0 0 CQ CO DOCUMENT DATE: 09/01/2020 <br /> I - - <br /> EVAPORATOR EVAPORATOR PROTO TYPE: <br /> 19 PROTO CYCLE: <br /> I 18 18 <br /> PROFESSIONAL SEAL <br /> > 8 <br /> FS P FFCO <br /> c� P FS OF ESS/ <br /> QR �N9 <br /> / I 4"Gw <br /> t+ — 1-D <br /> ICO m <br /> 0 0 + � -'NdA.E�'3�670 �' rn <br /> F-1 16 <br /> A <br /> GI �o 'Wig s' Cameron Collins <br /> DN:ticr" <br /> E=cam a ro n.co I l i ns@ rtmassociates.com, <br /> 1Q 4 Cameron Collins 0_RTM Engineering,OU=RTM, <br /> CN=Cameron Collins <br /> Date:2020.08.31 11:19:42-05 00' <br /> W <br /> i <br /> V) <br /> ID <br /> WASTE AND VENT PLAN <br /> 1 WASTE AND VENT PLAN <br /> �01 SCALE 3/16"-1'-0" NORTH <br /> SHEET: <br /> P201 <br /> Copyright Notice:This drawing was prepared for use on a specific site contemporaneously with <br /> BRR Original printed on recycled paper its issue date and it is not swtable for ase on a different projea site or at a later time.use of this <br /> drawing for reference or example on another project requires the services of properly licensed <br /> architects and engineers.Reproduction of this drawing for reuse on another project is not <br /> authorized and may be contrary to the law. <br />