Laserfiche WebLink
� ARO <br /> SEE ' S CANDIES SPECIFICATIONS <br /> Patrick C. <br /> a <br /> 15. FLOORING: B. ALL WATER LINES SHALL BE COPPER. 7$, C-214920 <br /> A. SUB FLOOR SHALL BE FLOATED SMOOTH FOR ALL FLOORING MATERIAL CHANGES. C. PROVIDE CONTROL VALVES, ALL OF THE MIXING VARIETY, AS MANUFACTURED BY <br /> 1. FRAMING: 7. DOORS: PRIOR TO FLOATING THE FLOOR WITH EITHER "ARDEX" OR "QUICKCRETE" THE SURFACE "AMERICAN STANDARD" OR APPROVED EQUAL. .JAN 31I 2021 <br /> MUST BE SOUND, CLEAN AND FREE OF OIL, GREASE, WAX, DIRT, ASPHALT, CURING <br /> A. ROLL-UP GRILLE TO BE "ALUMATEK, INC." WITH FINISHES AS SPECIFIED BY SEE'S D. PROVIDE SHUT-OFF VALVE ON INCOMING COLD WATER LINE AT PLUS 60" IN WING WALL �� <br /> A. METAL FRAMING: COMPOUNDS, LATEX AND GYPSUM COMPOUNDS, DUST, PAINT OR ANY CONTAMINATE �► Flag wal ` <br /> METAL STUDS SHALL BE A MINIMUM OF 20 GAUGE. AND WITH LEXAN INSERTS BETWEEN GRILLE SLATS. GRILLE AND HARDWARE TO BE WHICH MIGHT ACT AS A BOND BREAKER. ADJACENT TO 3 COMPARTMENT SINK WITH APPROVED ACCESS PANEL. .�► Date <br /> B. WOOD FRAMING: <br /> ENGINEERED, SUPPLIED AND INSTALLED BY MANUFACTURER AS DIRECTED BY GENERAL B. PROVIDE A SMOOTH TRANSITION AT ALL LOCATIONS WHERE FLOORING MATERIAL E. INSTALL CLEAN-OUTS AT ALL BENDS, ANGLES AND ENDS OF ALL WASTE LINES AND <br /> BLOCKING AND FURRING AS REQUIRED AND AS SHOWN ON PLANS: CHANGES. � <br /> CONTRACTOR, AND INCLUDES WHITE POWDER-COATED BOTTOM AND FOOT BAR. ABOVE ALL "T"-CONNECTIONS IN WALLS OF SINK WASTE LINES. <br /> FIRE RETARDANT TREATED WOODC. VINYL COMPOSITION TILE:JURISDICTION REQUIRED BY LOCAL AS . B. HARDWARE SHALL BE OPENABLE FROM INSIDE WITHOUT KEY OR SPECIAL KNOWLEDGE. F. ALL TRAPS, HOT WATER PIPES AND DRAIN PIPES SHALL BE INSULATED OR COVERED, <br /> ( ) <br /> DOORS TO BE PROVIDED WITH SIGN STATING "THIS DOOR TO REMAIN OPEN DURING BELOW LAVATORIES, 2006 INTERNATIONAL BUILDING CODE. <br /> 2. FINISH CARPENTRY: BUSINESS HOURS" WITH 1" HIGH LETTERS WITH CONTRASTING BACKGROUND. SEE PLANS 1. 12"X 12" VINYL COMPOSITION TILE - ALTERNATE BLACK AND WHITE ARMSTRONG G. STAINLESS STEEL UTILITY SINK SHALL HAVE THREE COMPARTMENTS WITH AN 18" <br /> A. INTERIOR MALL TRIM: POPLAR PAINTED, TYPICAL ALL CASINGS, TRIM, 14 ROUND ETC. / <br /> FOR REQUIRED ELECTRICAL WIRING AND LOCATION OF KEY SWITCHES AND/OR PUSH POLAR WHITE #51941 AND CLASSIC BLACK #51910 IN A BASKET WEAVE PATTERN DRAINBOARD AT EACH END. PROVIDE 8" BACK AND END SPLASH AT ALL WALLS. I hereby certify that this plan, specification, or report was <br /> / BUTTON CONTROLS. WITH A SOLID 6" BLACK BORDER ALONG THE WALL AT THE ENTRY (SEE PROJECT prepared by me or under my direct supervision and that I <br /> C. ANY QUESTIONS CONCERNING GRILLES AND PRICING SHALL BE DIRECTED TO SEE'S <br /> SAND, SEAL AND PAINT TO A SMOOTH FINISH WITH NO VISIBLE JOINTS. MANAGER FOR SPECIFICATIONS). SINK SHALL BE NSF APPROVED (PROVIDED BY SEE'S). am a duly Registered Architect under the laws of the B. PLYWOOD: ALL PLYWOOD PANELING TO BE 3/4" 'N' GRADE BIRCH. ALL EXTERIOR FINISH CANDIES PROJECT MANAGER. 2. BASE - ALL BASE TO BE 6" RUBBER BASE, BURKE "BLACK" #701P FOR NEW H. PROVIDE MINIMUM CAPACITY ELECTRIC WATER HEATER AS REQUIRED BY LOCAL State of CALIFORNIA <br /> WOODWORK SHALL BE INSTALLED WITH BOX NAILS - LENGTH AS APPROPRIATE, D. INTERIOR DOORS: WOOD DOORS SHALL BE 1-3/4" THICK SOLID CORE, 3'-0" IN WIDTH INSTALLATIONS; OTHERWISE, MATCH THE EXISTING. HEALTH DEPARTMENT, UNLESS OTHERWISE NOTED. SEE PLUMBING SHEETS C21492 <br /> COUNTERSUNK AND FILLED. FILL ALL FLUSH JOINTS, TOOL MARKS AND OTHER / FOR ADDITIONAL INFORMATION. Number Date <br /> BY 6'-8" IN HEIGHT (UNLESS OTHERWISE NOTED ON PLANS): PAINT GRADE BIRCH OR D. SHEET VINYL <br /> IMPERFECTIONS AND SAND SMOOTH, PLYWOOD TO BE FIRE RETARDANT TREATED IF I. PROVIDE G.I. METAL SMITTY PAN FOR WATER HEATER WITH DRAIN LINE SEPARATE This drawing is and will remain the property of the <br /> AS NOTED WITH WHITE/ BLACK TIMELY KNOCK DOWN METAL FRAME. 1. SHEET VINYL FLOORING WITH 6" SELF COVE TO BE ARMSTRONG'S MEDINTECH, ( g p p y <br /> REQUIRED BY LOCAL CODE). A MINIMUM BIRCH VENEER, GRADE N, SHALL BE1 2" FROM PRESSURE RELIEF VALVE OF WATER HEATER), BOTH TO DRAIN INTO MOP SINK architects and any reproduction or use for any but the <br /> USED FOR ALL WOODWORK. SUBSTITUTIONS MUST BE FIRST APPROVED BY SEE'S. E. INTERIOR DOORS: METAL DOORS SHALL BE 1-3/4", 3'-0" IN WIDTH BY 6'-8" IN #88476. USE 1 / PLASTIC COVE STICK. SECURE COVE STICK TO CONNECTION TO THE SEWER SYSTEM PIPING OR OTHER ACCEPTABLE RECEPTACLE specifically agreed upon purposes, without the prior <br /> HEIGHT (UNLESS OTHERWISE NOTED ON PLANS): 14 GAUGE METAL WILL BE THE FLOOR AND WALL WITH THE MANUFACTURES RECOMMENDED ADHESIVE. COVE RADIUS / written consent of the architects, is strictly prohibited. <br /> C. STOREFRONT CROWN MOLDING SHALL BE #3270 AS PROVIDED BY AURA HARDWOODS ACCEPTABLE MINIMUM. (USE A MINIMUM OF 20 GAUGE STEEL STUDS ON DOOR 1 1/2", HEAT THE SHEET VINYL AT THE BEND WHEN MAKING THE COVE CONFORM TO TO BE CONCEALED WITHIN WALLS. <br /> OR #SL/290 AS PROVIDED BY HOUSE OF MOLDINGS. OPENINGS) WITH A WHITE TIMELY KNOCK DOWN METAL FRAME. THE COVE STICK. APPLY MANUFACTURES ADHESIVE ON THE COVE STICK IN ORDER Information contained in these drawings was prepared <br /> for the specific site listed below. Use of these drawings for <br /> D. CAULKING: ALL JOINTS BETWEEN CABINETS, WALLS, SHELVES, ETC., SHALL BE FOR THE SHEET VINYL TO ADHERE TO THE COVE STICK. 20. ELECTRICAL WORK: any other location or project is strict) prohibited without <br /> F. FIRE RATED CORRIDOR DOORS SHALL BE 20-MINUTE MINIMUM (SUBJECT TO LOCAL p � y <br /> CAULKED. THERE SHALL BE NO OPEN JOINTS IN STORE. ALL CAULKING MATERIAL 2. PROVIDE CLEAR ALUMINUM J-MOLD AT TOP OF BASE. prior written consent of the architects. <br /> SHALL BE WHITE NON-YELLOWING 100% SILICONE. ALL BACKING SHALL BE REQUIREMENTS) METAL DOORS WITH SMOKE GASKET AND METAL FRAME. A. PROVIDE ALL LABOR, MATERIALS, EQUIPMENT AND TRANSPORTATION REQUIRED TO <br /> G. INTERIOR DOUBLE-ACTING DOOR SHALL BE A WHITE EASY SWING MODEL #LWD4 AS 3. PROVIDE CLEAR ALUMINUM CORNER PROTECTION ON BOTH INSIDE AND OUTSIDE PERFORM AND COMPLETE ALL ELECTRICAL WORK AS SHOWN ON DRAWINGS AND/OR <br /> POLYURETHANE FOAM. CAULKING SHALL BE TOOLED TO ASSUME COMPLETE WETTING CORNERS AS MANUFACTURED BY CRANE. SPECIFIED HEREIN. <br /> ACTION OF SEALANT TO JOINT FACES AND A SMOOTH EVEN SURFACE. AT MANUFACTURED BY ELIASON (PROVIDED BY SEE'S CANDIES). <br /> COMPLETION OF ALL CAULKING WORK, THE CONTRACTOR SHALL REMOVE ALL H. STOREFRONT SWING-TYPE ENTRY DOORS SHALL BE KAWNEER ALUMINUM ENTRANCE 4. ALL SEAMS TO BE HEAT WELDED. B. REFER TO REFLECTED CEILING PLAN FOR EXACT LOCATION AND TYPE OF ADDITIONAL <br /> SURPLUS CAULKING MATERIAL FROM ALL SURFACES. "500" WIDE STYLE, WITH OPTIONAL %" SQUARE GLASS STOPS; POWDER-COATED WHITE E. MARBLE TILE: TILE ONLY PROVIDED BY SEE'S LIGHT FIXTURES REQUIRED BY SEE'S, IF ANY. <br /> E. CAULKING AT THE NEUTRAL STRIP SHALL MATCH THE BLACK LAMINATE. CONCEALED DOOR CLOSERS, AND OFFSET C-STYLE BLACK VINYL PUSH/PULL HANDLES. 1. FLOOR TILE IN SALES AREA TO BE A 12"X12" ALTERNATE BLACK AND WHITE C. ELECTRICAL CIRCUITS USED FOR EXTERIOR SIGNAGE, EXTERIOR LIGHTS AND DISPLAY <br /> CHECKERBOARD PATTERN AS SHOWN ON DRAWINGS. ARIOSTEA NERO MARQUNIA (BLACK WINDOW, SHALL BE CONNECTED TO A 24-HOUR TIMER. <br /> 3. GYPSUM BOARD: I. SLIDING ENTRY DOORS SHALL BE KAWNEER SLIDING MALL FRONT #1010 WITH AND CREMO DELICATO (WHITE) W/BLACK GROUT UNLESS OTHERWISE SPECIFIED. TILE D. TIMECLOCK SHALL BE INTERMATIC #T101 OR APPROVED EQUAL. <br /> A. WALLS: 5/8" TYPE 'X' GYPSUM BOARD ON METAL STUDS, SPACED AT 16" O.C. INTERLOCK AND RECESSED FLOOR TRACK. WILL BE THIN SET INSTALLED. THE CHECKERBOARD PATTERN WILL INCLUDE A 6" E. ALL RECEPTACLES, OUTLETS, WALL SWITCHES, ETC., SHALL BE WHITE. <br /> B. RESTROOM CEILING AND SALES AREA SOFFITS: 5/8" TYPE 'X' GYPSUM BOARD. J. G.C. SHALL PROVIDE WHITE KAWNEER ENTRY DOORS. BLACK BORDER ALONG THE WALL AT THE ENTRY (SEE PROJECT MANAGER FOR F. ALL RESTROOMS SHALL USE LEVITON 1221-LHV LIGHTED TOGGLE SWITCH FOR <br /> C. RESTROOM AND ALL SINK LOCATION WALLS: 5/8" TYPE 'X' M.R. (MOISTURE 8. STOREFRONT GLASS: (OTHER THAN SLIDING STOREFRONT DOORS, TO BE BY G.C.) SPECIFICATIONS). LIGHTING (OR APPROVED EQUAL). <br /> 2. ENTRY TILE AS REQ'D SHALL BE 8"x8" AMERICAN GLEAN UP 65 OBSIDIAN BLACK TILE. <br /> A. 1/4 <br /> RESISTANT) GYPSUM BOARD. G. ALL LIGHT FIXTURES AND LAMPS WILL BE PROVIDED BY SEE'S UNLESS NOTED <br /> " CLEAR POLISHED PLATE. ALL GLASS SHALL BE TEMPERED SAFETY 3. GROUT JOINTS SHALL BE A MAXIMUM OF 1/8 OF AN INCH. MBA PROJECT MANAGEMENT, LLC <br /> D. ALL TAPING, FILLING AND SANDING TO ENAMEL PAINT SMOOTH FINISH, AND, SUBJECT GLASS AS APPLICABLE. <br /> 4. ALL CERAMIC TILE TO BE INSTALLED IN ACCORDANCE WITH THE RECOMMENDATIONS OTHERWISE ON THE PLANS. <br /> TO SEE'S CANDIES' APPROVAL. B. ALL VERTICAL CORNERS OF SHOW WINDOWS SHALL BE MITERED AND SEALED WITH CONTAINED IN THE "HANDBOOK FOR CERAMIC TILE INSTALLATION," LATEST EDITION, H. THE MATERIALS AND EQUIPMENT SHOWN ON THE DRAWINGS AND/OR HEREIN N5560 CTH ZM, SUITE 3 <br /> 4. STOREFRONT ALUMINUM: CLEAR SILICONE. OF THE TILE COUNCIL OF AMERICA. SPECIFIED SHALL BE NEW, IN UNBROKEN PACKAGES, OF THE SAME TYPE AND Onalaska, WI. 54650 <br /> C. ALL GLASS SHALL BE SET ON RUBBER OR VINYL SETTING BLOCKS. 5. REVIEW ALL AREAS TO RECEIVE TILE FLOORING PRIOR TO SUBMITTING AN ESTIMATE MANUFACTURER AND FURNISHED IN ACCORDANCE WITH SPECIFICATIONS OF THE <br /> A. DISPLAY WINDOW FRAME SHALL BE KAWNEER GLASS STOP ASSEMBLIES WITH ( ) AMERICAN INSTITUTE OF ELECTRICAL ENGINEERS, NATIONAL BOARD OF FIRE 608-785-2760 CELL: 507-458-8034 <br /> FINISHES AS SPECIFIED BY SEE'S. ALL ALUMINUM STOREFRONT FRAMES WILL BE D. ALL GLASS SHALL BE SMOKE GASKETED. (SILICON WILL NOT BE ACCEPTED IN PLACE TO DETERMINE THE REQUIRED EXTENT OF SUBFLOOR PREPARATION. UNDERWRITERS AND THE NATIONAL ELECTRIC CODE. ALL ELECTRIC EQUIPMENT AND <br /> SUPPLIED BY G.C. BASED ON DIMENSIONS AS VERIFIED IN THE FIELD BY THE OF GASKET.) 6. SET AND GROUT TILE WHEN AMBIENT TEMPERATURE IS A LEAST 50' AND RISING. MATERIALS SHALL BEAR THE UNDERWRITERS' LABEL. E-mail: mbapm.tim@gmail.com <br /> CONTRACTOR. E. FACETED GLASS SHALL BE 3/4" BEVEL EXPOSED ON ALL FOUR EDGES OF EACH ALIGN ALL JOINTS AND CORNERS. <br /> I. NAMEPLATES SHALL BE FURNISHED AND INSTALLED FOR ALL SWITCHBOARD OR POWER <br /> B. DISPLAY WINDOW SASH SHALL BE KAWNEER 69-253 IN WHITE UNLESS PLANS PIECE BUTTED TOGETHER. F. CERAMIC TILE BASE: TILE ONLY PROVIDED BY SEE'S BOARD, MOTOR STARTER, SIGNAL TERMINAL CABINET, TRANSFORMER OR OTHER <br /> REFERENCE A DIFFERENT SYSTEM. F. WINDOW VINYL SHALL BE 3M BRAND SCOTCH CAL PLUS SERIES 1. INTERIOR: 6"X6" CERAMIC TILE SANITARY COVE BASE MANUFACTURED BY SIMILAR ELEMENT OF THE ELECTRICAL SYSTEM. NAMEPLATES SHALL BE FULLY <br /> C. GLASS STOP ASSEMBLIES FOR HEAVY GLASS TO BE KAWNEER "TRI-FAB." #3650-12 BLACK (AS REQUIRED ON PLAN SET) AMERICAN OLEAN TILE CO. COLOR IS HIGH-GLOSS BLACK #049 OR EQUAL AS DESCRIPTIVE OF TITLE, VOLTAGE, AND PHASE AS APPLICABLE AND INSTALLED INSIDE <br /> D. ANY QUESTIONS CONCERNING DISPLAY AND MALL FRONT WINDOW SHALL BE DIRECTED 9. HARDWARE: APPROVED BY SEE'S AND LOCAL AUTHORITY. PROPER INSTALLATION REQUIRES THE DOOR NEAR THE TOP. EACH MOTOR SHALL BE IDENTIFIED WITH A PAINTED OR <br /> TO THE SEE'S PROJECT MANAGER. A. ALL HARDWARE TO HAVE SATIN, CHROMIUM 626 FINISH. COVE BASE TO BE INSTALLED PRIOR TO FIELD TILE. METAL STENCIL. IN ALL INSTANCES, USE THE DESIGNATIONS OR TITLES USED ON THE <br /> B. PROVIDE SEE's CANDIES WITH 2 KEYS FOR EACH LOCKSET UPON TURNOVER. 2. WOOD STOREFRONT: 6"X6" CERAMIC TILE SURFACE BULLNOSE AS MANUFACTURED DRAWINGS EXCEPT OTHERWISE DIRECTED. <br /> 5. STOREFRONT TILE: C. ALL DOORS WITH EXPOSED DOOR CLOSERS TO HAVE NORTON 1601BF DOOR CLOSERS BY AMERICAN OLEAN TILE CO. COLOR IS HIGH-GLOSS BLACK #049. J. ALL MATERIALS SHALL COMPLY WITH THE APPLICABLE BUILDING CODE AND AS SHOWN <br /> AS MANUFACTURED BY NORTON G. GROUTING: ON THE ELECTRICAL DRAWINGS. CLIENTS <br /> GROUTING: K. ALL ELECTRICAL PANELS SHALL HAVE ACCURATE TYPED PANEL SCHEDULES. STORE NUMBER SF-94 <br /> A. GROUT AT STOREFRONT BASE BLACK TILES IS TO BE CUSTOM BUILDING PRODUCTS D. DOOR BETWEEN SALES AND WORKROOM- SIMPLEX MECHANICAL DOOR LOCK <br /> ( ) MODEL # 5021 XD-WL-26D41 1. GROUT: 21. ROOF SHINGLES: <br /> PRISM SURECOLOR GROUT, #60 CHARCOAL. E. ALL LATCH SETS AND LOCKS AS MANUFACTURED BY SCHLAGE "D" SERIES, LEVON. A. GROUT IS TO BE PRISM SURECOLOR, #60 CHARCOAL BY CUSTOM BUILDING PRODUCTS A. SHALL BE CLASS A FIBERGLASS/ASPHALT ROOF SHINGLES, UNLESS OTHERWISE NOTED. <br /> B. GROUT AT STOREFRONT (WHITE TILES) IS TO BE CUSTOM BUILDING PRODUCTS FUNCTIONS: AT STOREFRONT WHERE GLOSS BLACK TILES ARE CALLED OUT. B. SHALL BE TIMBERLINE CHARCOAL BLEND AS MANUFACTURED BY GAF BUILDING SEES CANDIES <br /> PRISM SURECOLOR GROUT, #381 BRIGHT WHITE. 1. DOOR AT TOILET - A405 B. GROUT IS TO BE PRISM SURECOLOR, #381 BRIGHT WHITE BY CUSTOM BUILDING MATERIALS CORP. <br /> C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADVISING SEE'S OF THE PROPER PRODUCTS AT STOREFRONT WHERE POLAR WHITE TILES ARE CALLED OUT. C. ANY SUBSTITUTION MUST FIRST BE APPROVED BY SEE'S. 2164 DANIELS STREET <br /> QUANTITIES NEEDED TO COMPLETE THE PROJECT (ALL TILE TO BE SUPPLIED BY 22. MECHANICAL: <br /> SEE'S). C. FLOOR TILE GROUT IS TO BE SPECTRA LOCK #22 MIDNIGHT BLACK TRADITIONAL <br /> F. ALARM LOCK SET AS MANUFACTURED BY ALARM LOCK SYSTEMS INC. GROUP "I BY LATICRETE A. HVAC DIFFUSERS SHALL BE TITUS 24 X 24 PERFORATED, MODEL #PCS (SUPPLY) <br /> D. ALL FIELD TILE SHALL BE 6" X 6" POLAR WHITE (05) OR 6" X 6" GLOSS BLACK (49) 1. DOOR DOOR AT CORRIDOR - ALARM LOCK #250x28 WITH RIM CYLINDER CERKA-12345 AND #PAR (RETURN), WHITE IN COLOR #25 OR APPROVED EQUAL. <br /> AS MANUFACTURED BY AMERICA OLEAN. TRIM TILES SHALL BE PER THE G. BUTT HINGES: STANLEY, 5055 OR MCKINLEY, SATIN CHROME FINISH. 2. TILE MUST BE FIRMLY SET PRIOR TO GROUTING. THIS USUALLY TAKES AT LEAST B. THERMOSTAT SHALL BE HONEYWELL COMMERCIAL VISION PRO #TB8220U1003 OR APPROVED EQUAL. <br /> BLUEPRINTS. H. ALL DOORS TO HAVE DOORSTOPS FOR THE PROTECTION OF WALLS AND DOORS. 24 HOURS. IF THE TEMPERATURE IS BELOW 60° DEGREES FAHRENHEIT, WAIT C. A JDS SERIES (OR EQUAL) JIFFY DURO DYNE BUTTERFLY DAMPER SHALL BE <br /> E. ALL BASE TILE SHALL BE 6" X 6" GLOSS BLACK (49) AS MANUFACTURED BY 48-72 HOURS BEFORE GROUTING. REQUIRED AT EACH DIFFUSER. <br /> AMERICAN OLEAN. 10. SIGNS: 3. SEAL THE TILE WITH TILE SEALER TO PREVENT THE GROUT FROM STAINING THE 23. UTILITY SERVICES: <br /> F. CROWN MOLDING CORNICE CAP #10 AND CAP #11 (ONLY WHEN REQUIRED) SHALL BE A. ALL SIGNS TO BE SUPPLIED AND INSTALLED BY SEE'S CANDIES. ANY SIGN TILE. APPLY EVEN COATS OF SEALER WITH LAMBS WOOL APPLICATOR OR SPONGE EVERY EFFORT HAS BEEN MADE TO DETERMINE AS ACCURATELY AS POSSIBLE THE MANTECA CA 95336 <br /> ULTRA WHITE (F-100) AS MANUFACTURED BY WESTMINSTER CERAMICS OF QUESTIONS SHALL BE DIRECTED TO SEE's PROJECT MANAGER. ACCORDING TO LABEL DIRECTIONS. WHEN SEALER NO LONGER PENETRATES, THE REQUIREMENTS OF THE ELECTRICAL AND TELEPHONE SERVICES. HOWEVER, BEFORE <br /> BAKERSFIELD. SEE BLUEPRINTS FOR INSTALLATION DETAILS. SURFACE IS SEALED. <br /> G. ALL GROUT COLOR SHALL MATCH THE ADJACENT TILE. B. PRIOR TO FABRICATION AND INSTALLATION OF EXTERIOR SIGNS, SIGN CONTRACTOR SUBMITTING BID, CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS SHOWN ON THE <br /> H. ALL INSTALLATIONS SHALL BE PER THE BLUEPRINTS AND PER ACCEPTABLE TILE TO OBTAIN REQUIRED SIGN PERMITS FROM THE CITY PLANNING 4. IF SPACERS WERE USED TO HELP ALIGN TILE, REMOVE THEM. PLANS AND SHALL INCLUDE SUFFICIENT FUNDS FOR MATERIAL AND LABOR FOR <br /> COUNCIL OF AMERICA (TCA) INSTALLATION STANDARDS. AND BUILDING DIVISION. 5. MIX GROUT ACCORDING TO PACKAGE INSTRUCTIONS. TERMINATION ON POLES, WORK IN VAULTS, ETC. IN ADDITION, ALL COSTS FOR PULLINGossol <br /> 9 <br /> C. DRAWINGS TO BE PROVIDED BY SIGN CONTRACTOR AND APPROVED BY SEE'S CANDIES6. USING A RUBBER FLOAT AT A 45°-DEGREE ANGLE, SPREAD THE GROUT OVER THE IRONS, GROUNDING, CABLE CHARGES, ETC. LEVIED BY THE SERVING UTILITY OR ANYAND LANDLORD. ENTIRE TILE SURFACE AND PRESS INTO THE JOINTS UNTIL THEY ARE COMPLETELY OTHER WORK WHICH IS REQUIRED FOR ELECTRICAL AND TELEPHONE SERVICE TO THE <br /> FILLED. PROJECT MUST BE INCLUDED AT NO ADDITIONAL COST TO SEE'S. AFTER THE CONTRACT <br /> 6. STOREFRONT/TILE: INSTALLATION D. GENERAL CONTRACTOR IS TO COORDINATE THE LAYOUT AND INSTALLATION OF THE 7. HOLD THE EDGE OF THE GROUT FLOAT AT A 90°-DEGREE ANGLE TO REMOVE ALL HAS BEEN AWARDED, THE CONTRACTOR SHALL ARRANGE FOR BOTH TEMPORARY AND 0 <br /> FRAMING: SIGN WITH THE SIGN CONTRACTOR. EXCESS GROUT. POSITION THE FLOAT DIAGONALLY TO THE GROUT JOINTS SO YOU PERMANENT SERVICES AND ADVISE THE UTILITY WHEN FINAL LOADS WILL BE CONNECTED. ED <br /> A. FRAMEWORK SHALL MEET THE MINIMUM REQUIREMENTS OF ANSI A108, SECTION A-3. 11. CABINETS AND TRADE FIXTURES: WON'T PULL UP THE GROUT ALREADY IN THE JOINTS. 24. PROTECTION: /�H E 8 <br /> B. FRAMEWORK MEMBERS SHALL BE STRAIGHT, PLUMB OR LEVEL, OF UNIFORM DIMENSION A. CABINETS AND TRADE FIXTURES SHALL BE SUPPLIED BY SEE's CANDIES AND 8. SMOOTH AND FINISH OFF THE GROUT WITH A DAMP TOWEL OR SPONGE (MAKE PROTECT ALL WORK, MATERIALS AND EQUIPMENT FROM DAMAGE FROM ANY CAUSE <br /> AND ALIGNED TO PROVIDE SQUARE CORNERS. MAXIMUM VARIATION FROM INSTALLED BY CONTRACTOR. (SEE SEE'S SUPPLIED ITEMS FOR THE LIST) SURE IT'S DAMP, NOT WET) IN A CIRCULAR MOTION. WRING OUT THE SPONGE AND WHATSOEVER, AND PROVIDE ADEQUATE AND PROPER STORAGE FACILITIES DURING 3423 S LA. CIENEGA BLVD. <br /> REQUIRED PLANE SHALL BE 1/8" IN 8 FEET FOR FLOOR JOISTS, WALL STUDS AND B. ANY CABINETRY QUESTIONS SHALL BE DIRECTED TO SEE'S PROJECT MANAGER. GO OVER THE AREA TO REMOVE EXCESS GROUT FROM THE SURFACE OF THE TILE. PROGRESS OF THE WORK. PROVIDE FOR THE SAFETY AND THE GOOD CONDITION OF THE LOS ANGELES, CA 90016 <br /> CEILING JOISTS. C. THE CONTRACTOR SHALL CAULK ALL JOINTS BETWEEN CABINETS, WALLS, SHELVES, ETC. 9. IF A SLIGHT HAZE REMAINS ON THE TILE AFTER THE GROUT HAS DRIED, BUFF IT WORK UNTIL FINAL ACCEPTANCE BY SEES. REPLACE ALL DAMAGED OR DEFECTIVE WORK, PH: 310/287-4616 <br /> C. SUPPORT FRAMING SHALL BE DESIGNED FOR A MAXIMUM ALLOWABLE ASSEMBLY THERE WILL BE NO OPEN JOINTS IN THE STORE. OFF WITH CLEAN DRY CLOTH. (IF STAINING APPEARS, REMOVE WITH PHOSPHORIC MATERIALS AND EQUIPMENT BEFORE REQUESTING FINAL ACCEPTANCE. SEE MALL LEASE <br /> DEFLECTION OF L/360 UNDER ALL INTENDED LIVE LOADS. D. ALL CAULKING SHALL BE TOOLED TO ASSURE COMPLETE WETTING ACTION OF SEALANT ACID AND WATER SOLUTION) PACKAGE FOR ADDITIONAL CONDITIONS AND RESTRICTIONS. FAX: 310842-4436 <br /> D. FRAMING MEMBERS SHALL BE SPACED A MAXIMUM OF 16" ON CENTER. TO JOINT FACES AND A SMOOTH, EVEN SURFACE. ** ALLOW GROUT TO SET FOR 24 HOURS BEFORE WALKING ON IT. ** 25. CONFORMANCE WITH LEASE AGREEMENT: <br /> SUBSTRATE/CEMENTUOUS BACKER: E. THE SILICONE SHALL BE DOW CORNING 999A OR A SEE'S CANDIES APPROVED EQUAL. 10. AFTER 24 HOURS HAVE ELAPSED YOU CAN BEGIN DAMP CURING. LIGHTLY DAMPEN ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH LEASE AGREEMENT BETWEEN SEE'S CONTACT <br /> GROUT INSTALLATION BY SPRAY MISTING WITH COOL WATER SEVERAL TIMES A DAY SEE'S AND LANDLORD. <br /> A. APPLY CEMENTUOUS BACKER UNITS TO FRAMING WITH LONG DIMENSION ACROSS F. WHITE SEAM FILL SHALL BE USED AT LAMINATE JOINTS. FOR 3 CONSECUTIVE DAYS. THIS WILL HELP GROUT TO DRY AN EVEN COLOR AND RICHARD ESCALANTE <br /> FRAMING. CENTER END OR EDGE JOINTS ON FRAMING AND STAGGER JOINTS IN12. PLEXIGLASS: <br /> COULD HELP PREVENT CRACKING. 26. SEE'S SUPPLIED ITEMS: 310 287-4616 <br /> ADJACENT ROWS. SPACE ENDS AND EDGES IN ACCORDANCE WITH MANUFACTURER'S A. GLOSS BLACK PLEXIGLASS (IF SHOWN) TO BE ROHM-HAAS, 3/16: #2025. H. SEALING: THE FOLLOWING LISTS OF ITEMS SHALL BE FURNISHED BY SEE'S CANDIES AND <br /> RECOMMENDATIONS. B. WHITE PLEXIGLASS TO BE ROHM-HAAS, 3/16: #7328. 1. ALLOW GROUT TO SET FOR 24 HOURS BEFORE APPLYING SEALER. INSTALLED BY THE CONTRACTOR (UNLESS NOTED DIFFERENTLY PER PLAN): Tim R. Benson <br /> B. FASTEN TO WOOD OR STEEL FRAMING PLACING NAILS OR SCREWS A MAXIMUM OF C. MATTE BLACK PLEXIGLASS, IF SHOWN, SHALL BE 3/16: #P95 2025. 2. APPLY SEALER IN EVEN COATS WITH LAMBS WOOL APPLICATOR OR SPONGE A. CABINETS/TRADE FIXTURES: (AS INDICATED ON PLANS) ARCHITECT'S PROJECT MANAGER <br /> 8" O.C. IN THE FIELD AND 6" ON THE SEAMS. PROVIDE ADDITIONAL BLOCKING WHERE 13. PLASTIC LAMINATE: ACCORDING TO PRODUCT DIRECTIONS. WHEN SEALER NO LONGER PENETRATES, THE 1. BACK BAR (INCLUDING BACK SPLASH) 608/ 785-2760 <br /> REQUIRED TO PERMIT PROPER ATTACHMENT. EDGES OR ENDS OF UNIT PARALLEL TO SURFACE IS SEALED. ALLOW SEALER TO DRY FOR 24 HOURS PRIOR TO 2. BULK CANDY DISPLAY CASE, INCLUDING GLASS - GLASS INSTALLATION BY G.C. <br /> FRAMING SHALL BE CONTINUOUSLY SUPPORTED. A. DISPLAY WINDOW PLASTIC LAMINATE SHALL BE STANDARD-GRADE, HIGH GLOSS WALKING ON SURFACES. 3. ALL SELF-SERVICE CASES <br /> C. HOLD CBU FIRMLY IN CONTACT WITH FRAMING WHILE DRIVING FASTENERS. DO NOT WHITE (90), #949, AS MANUFACTURED BY FORMICA CORPORATION. I 4. REGISTER, REGISTER SHROUD AND CHECK-OUT COUNTERS o <br /> . SEALED CONCRETE: <br /> OVERDRIVE SCREWS AND REPLACE ANY SCREWS THAT ARE STRIPPED. WHERE CBU B. MALL FRONT BLACK PLASTIC LAMINATE, IF SHOWN, SHALL BE STANDARD MATTE (58), 5. SHADOW BOX DISPLAY CASE -o L <br /> JOINTS MEET ON STEEL FRAMING MEMBERS, ATTACH CBU TO WEB SIDE OF FLANGE FINISH #909, AS MANUFACTURED BY FORMICA CORPORATION. 1. MOISTURE BLOCKING EPDXY PRIMER IS TO BE VAPOR SEAL BY BDC AT ALL 6. LIGHT SOFFIT (INCL. EGG CRATE LENS) ° - °o <br /> FIRST. C. DISPLAY WINDOW TABLETOP WILL BE BLACK POLISHED (90) LAMINATE. LOCATIONS WHERE SEALED CONCRETE IS CALLED OUT. 7. GONDOLA (FREE-STANDING, SELF-SERVICE) a) c o <br /> JOINT TREATMENT: D. ALL PLASTIC LAMINATE SHALL BE INSTALLED PER MANUFACTURE'S RECOMMENDATIONS. 2. FLOOR COATING IS TO BE TWO PART EPDXY SYSTEM, BD B. LETTERS FOR FLAREBOARDS (WHERE APPLICABLE)CLASSICS 3100, #10 CAPE date -� 2 o- 6 > comments <br /> A. FILL ALL JOINTS AND CORNERS OF CEMENTUOUS BACKER UNITS WITH TILE SETTING E. ALL BASE MATERIAL TO RECEIVE PLASTIC LAMINATE SHALL BE 3/4" BIRCH VENEER COD GREY BY BDC AT ALL LOCATIONS WHERE SEALED CONCRETE IS CALLED OUT. AS <br /> MATERIAL AND TAPE ACCORDING TO MANUFACTURER'S REQUIREMENTS TO PROVIDE A GRADE N, SMOOTH AND FREE OF KNOTS, HOLES AND OTHER IMPERFECTIONS THAT MAY 3. INSPECT AND PREP CONCRETE AS REQUIRED BY MANUFACTURER SPECIFICATIONS. C. DISPLAY WINDOW WOOD LATTICE DOORS (PRE-FINISHED, WHERE APPLICABLE) BUILT 07/03/20 O <br /> SMOOTH FINISH. SHOW UP AS BUMPS, RIDGES OR RIPPLES AFTER THE LAMINATE HAS BEEN INSTALLED. 16. 4. MIX AND INSTALL EPDXY SYSTEMS AS REQUIRED BY MANUFACTURER SPECIFICATIONS. D. LIGHT FIXTURES, LAMPS, DIFFUSERS AND SHADES PRELIM <br /> TILE: <br /> 14. PAINTING: E. STOREFRONT SIGNAGE (COORDINATION) REVIEW 08/03/20 O O <br /> A. INSTALL TILE IN AREAS INDICATED FROM LEASELINE TO TRANSITION. USE ADHESIVES A. GYPSUM BOARD SUSPENDED CEILING: F. CERAMIC BASE TILE AND MARBLE FLOOR TILE (WHERE APPLICABLE) BID/ <br /> AND APPLY ONLY AS RECOMMENDED BY MANUFACTURER AND IN ACCORDANCE WITH 1. SURFACE PREPARATION: SURFACES MUST BE CLEAN AND DRY. JOINTS SHALL BE A. ACOUSTICAL CEILING BOARD IN SALES AREA ONLY: G. CERAMIC WALL TILE (WHERE APPLICABLE) PERMIT 08/10/20 O O O O O <br /> INDUSTRY STANDARDS, AND SEE'S SPECIFICATIONS. PROPERLY TAPED, FILLED DRIED AND SANDED TO A LEVEL, UNIFORM SURFACE. 2' X 2' EXPOSED T-BAR SUSPENDED CEILING WITH VINYL GYPSUM BOARD PANELS. H. ALL PAPER TOWEL AND SOAP DISPENSERS. <br /> B. INSTALLERS MUST BE SPECIALISTS WITH A MINIMUM OF FIVE (5) YEARS EXPERIENCE. CRACKS, GOUGES, NAIL HOLES AND OTHER IMPERFECTIONS SHALL BE FILLED WITH CEILING PANELS AND GRID SHALL BE FACTORY FINISHED WHITE. (CEILING BOARD J. SAFE. <br /> C. ALL INSTALLATION SHALL CONFORM TO THE LATEST APPLICABLE TILE COUNCIL OF SPACKLING COMPOUND OR PATCHING PLASTER. PATCHED AREAS SHALL BE SANDED SHALL PASS ALL LOCAL HEALTH CODES FOR FOOD SERVICE AREAS). K. BACKROOM DESK AND ORGANIZER. <br /> AMERICA AND ANSI STANDARDS. BEFORE FINISHING. SAND LIGHTLY BETWEEN ALL COATS. B. ACOUSTICAL CEILING BOARD IN WORKROOM ONLY: <br /> D. DO NOT COMMENCE INSTALLATION UNTIL SUBSTRATE HAS BEEN MADE SUITABLE FOR 2• PRIME COAT: APPROPRIATE UNDERBODY AS SPECIFIED BY MFR. OF "SEE'S WHITE" 2' X 4' EXPOSED T-BAR SUSPENDED CEILING WITH VINYL GYPSUM BOARD PANELS. <br /> TILE INSTALLATION. SHALL BE APPLIED IN ACCORDANCE WITH MANUFACTURE'S DIRECTIONS. CEILING PANELS AND GRID SHALL BE FACTORY FINISHED WHITE. (CEILING BOARD <br /> E. REVIEW ALL AREAS TO RECEIVE TILE PRIOR TO SUBMITTING ESTIMATE TO DETERMINE 3. AVOID APPLICATION OF SEALER COAT AT TEMPERATURES BELOW 50 DEGREES SHALL PASS ALL LOCAL HEALTH CODES FOR FOOD SERVICE AREAS). <br /> THE REQUIRED EXTENT OF SUBSTRATE PREPARATION. FAHRENHEIT, OR WHERE STRONG DRAFTS OF AIR WILL BLOW ACROSS THE SURFACE C. ACOUSTICAL SUSPENSION SYSTEM: <br /> F. SET AND GROUT TILE WHEN AMBIENT TEMPERATURE IS AS LEAST 50' AND RISING. WHILE DRYING. DONN D X 24 - 2 X 2 AND 2 X 4 AS SHOWN ON PLAN. SYSTEM TO BE COLORED <br /> ALIGN ALL JOINTS AND CORNERS. 4. FIRST COAT: TO BE "SEE'S WHITE" AS SUPPLIED BY G.C. AND SHALL BE WHITE. FLAME SPREAD TO BE LESS THAN 25. - Deferred submittals will be required for the storefront awning and drawn by: checked by: <br /> APPLIED WITH A FINE NAP ROLLER TO PRODUCE A VERY FINE UNIFORM TEXTURE 17. TOILET/WORKROOM ACCESSORIES: signage. These deferred submittals shall first be submitted to the <br /> G. CLEAN METAL AND WOOD SURFACES AND CONCRETE FLOORS, REMOVING ALL FOREIGN ON THE SURFACE. <br /> MATTER AND CONTAMINANTS SUCH AS GREASE, OIL, DUST, WATER, SURFACE DIRT, A. ALL TOILET ROOM ACCESSORIES TO BE SUPPLIED AND INSTALLED BY CONTRACTOR project architect and /or engineer for review and coordination. TRB TRB <br /> OLD SEALANTS OR GLAZING COMPOUNDS, AND PROTECTIVE COATINGS, METAL SHALL NOTE: ANY IMPERFECTIONS REVEALED AFTER PRIME OR AND INSTALLED AS PER TITLE 24 HANDICAPPED STANDARDS WITH THE EXCEPTION Submittal to the city shall follow. A letter of approval from the <br /> FIRST COAT WILL BE ELIMINATED PRIOR TO APPLICATION OF PAPER TOWEL AND SOAP DISPENSERS. architect engineer must also be provided. <br /> BE CLEANED BY MECHANICAL OR SOLVENT PROCEDURES. / 9� <br /> H. INSTALL TILE TO CONCRETE SUBSTRATE PER TCA STANDARD'S F113-89 WITH OF SECOND COAT. B. THE FRP USED ON ALL SURFACES SHALL BE P199 BRIGHT WHITE AS MANUFACTURED THIS SHEET CONTAINS: <br /> UNIFORMLY SPACE 1/8" JOINTS, TO PATTERN INDICATED IN THE DRAWINGS, OR AS 5. SECOND COAT: TO BE "SEE'S WHITE" AS SUPPLIED BY G.C. BY MARLITE WITH TRIM COLOR TO MATCH. SEE PLANS FOR SPECIFIC LOCATIONS. SPECIFICATIONS <br /> SPECIFIED BY SEE'S CANDIES. VERIFY LAYOUT AND CUTS WITH PROJECT MANAGER SALES AREA TO HAVE A SMOOTH EVEN FINISH. <br /> PRIOR TO COMMENCEMENT OF WORK. CUT TILE AT WALL INTERSECTIONS FOR B. WOODWORK: C. HEAVY DUTY BRACKET SUPPLIED AND INSTALLED BY G.C. @ 32" O.C. <br /> CONCEALMENT BY BASE WHERE APPLICABLE. VARY MORTAR THICKNESS, AS NECESSARY 1. SURFACE PREPARATION: SURFACES MUST BE CLEAN AND DRY. SEAL KNOTS, SAP STANLEY #257555-795 WHITE <br /> TO ACCOMMODATE VARIATIONS IN TILE THICKNESS. STREAKS AND PITCH WITH SHELLAC. SAND NEW OR UNFINISHED WOOD AS REQUIRED. 18. FIRE SPRINKLERS: (UNLESS OTHERWISE NOTED) <br /> I. CLOSE AREAS IN WHICH TILE IS BEING PLACED TO TRAFFIC AND OTHER WORK. KEEP NAIL HOLES, CRACKS, AND SEAMS SHALL BE FILLED. WHEN USING PUTTY TO FILL, A. SYSTEM SHALL MEET ALL CODE REQUIREMENTS. <br /> AREA CLOSED UNTIL TILE IS FIRMLY SET. PROTECT TILE WORK FROM DAMAGE. APPLY IT AFTER THE FIRST COAT HAS DRIED. WHEN USING PLASTIC WOOD FILLER, B. ALL SPRINKLER HEADS IN SALES AREA TO BE RECESSED IN CEILING <br /> REPLACE DAMAGED TILE AT NO ADDITIONAL COST TO SEE's CANDIES. APPLY AND SMOOTH PRIOR TO APPLICATION OF THE FIRST COAT OF PAINT. (HEAD FLUSH TO CEILING) WITH SNAP-OFF WHITE COVER PLATES. <br /> J. INSTALL TILE TO WOOD SURFACES AND ALUMINUM GLAZING CHANNEL AND METAL BASE 2. PRIME ALL SURFACES THAT WILL RECEIVE PAINT PRIOR TO APPLICATION OF "SEE'S C. WALL MOUNT ONE OR MORE IF REQUIRED (1) 2A10BC RATED FIRE EXTINGUISHER, <br /> WITH DOW CORNING 795 SILICONE BUILDING SEALANT, BEADS AT 7" ON CENTER WHITE" IN ACCORDANCE WITH THE MANUFACTURERS SPECIFICATIONS. <br /> MAXIMUM. 3. FIRST COAT: "BEE'S WHITE" AS SUPPLIED BY G.C.. SHALL BE SPRAYED RECHARGEABLE WITH DATE TAGS. (SUPPLIED BY G.C.). <br /> K. GROUT SHALL BE FLUSH WITH EDGES OF THE TILE. WIPE TILES WITH CHEESECLOTH IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS. (IF CONDITIONS DON'T ALLOW, D. INSTALL TWO (2) APPROVED SMOKE DETECTORS, CEILING MOUNTED. ONE IN WORK <br /> INSTEAD OF SPONGE. CONTACT SEE'S PROJECT MANAGER). AREA, ONE IN SALES AREA AND IN HVAC DUCTS AS SHOWN ON APPROVED <br /> L. DAMP CURE MORTAR AND GROUT PER MANUFACTURER'S RECOMMENDATIONS. 4. FINISH COAT: "SEE'S WHITE" AS SUPPLIED BY G.C.. (ONE OR TWO COATS MECHANICAL PLANS FOR THE PROJECT (ONLY IF REQUIRED). <br /> M. SEAL TILE PER MANUFACTURER'S WRITTEN INSTRUCTIONS WITH SEALER RECOMMENDED AS DIRECTED BY OWNER.) FINISH COATS SHALL BE APPLIED AS IN PARAGRAPH 19. PLUMBING: <br /> FOR THE TILE INSTALLED. DOUBLE SEAL ALL JOINTS. B3 ABOVE. A. PLUMBING WORK SHALL CONSIST OF FURNISHING AND INSTALLING ALL LABOR, <br /> C. PAINT: MATERIALS AND EQUIPMENT TO COMPLETE ALL PLUMBING WORK AS SHOWN ON THE <br /> SEE'S CANDIES TO SUPPLY COLOR COAT PAINT ONLY. BENJAMIN MOORE WATERBORNE DRAWINGS AND/OR SPECIFIED HEREIN. THE FOLLOWING LIST IS FOR THE CONVENIENCE <br /> HIGH GLOSS ACRYLIC. GC TO SUPPLY WOOD SEALERS, PRIMERS, ETC. COMPATIBLE WITH OF THE CONTRACTOR AND IS NOT NECESSARILY ALL-INCLUSIVE: <br /> G.C.'S SUPPLIED PAINTS. PROVIDE LOW ODOR PRODUCTS AS REQUIRED BY LOCAL 1. SOIL, WASTE, VENT, SANITARY CONNECTIONS TO UTILITIES AS INDICATED <br /> JURISDICTIONS. 2. CONCRETE SAWING <br /> D. FIRE-RETARDANT PRIMER: 3. ACCESS DOORS FOR ACCESS TO PLUMBING VALVES <br /> ALL EXPOSED WOOD TO HAVE FIRE-RETARDANT PRIMER, SHERWIN-WILLIAMS "FLAME 4. HOT AND COLD WATER PIPING <br /> 5. AC CONDENSATE PIPING <br /> CONTROL" NO. 2020 ON ALL SURFACES PRIOR TO FINISH PAINTING. SUPPLIED BY GC. <br /> (ONLY IF REQUIRED BY LOCAL JURISDICTION). 6. STAINLESS STEEL UTILITY SINK WITH HOT AND COLD WATER (SINK & FAUCET <br /> SUPPLIED BY SEE'S CANDIES) <br /> 7. HAND SINK AND LAVATORY WITH HOT AND COLD WATER <br /> 8. MOP SINK WITH HOT AND COLD WATER <br /> 9. ALL FLOOR DRAINS TO BE SELF-PRIMING (IF USED) ARCHITECT'S COMMISSION NUMBER <br /> 10. WATER HEATER AND ALL ASSOCIATED SUPPLY AND DRAIN LINES 20 - 1010 . 008 <br /> 11. ANY OTHER SINKS AS SHOWN ON THE PLUMBING PLANS REFLECTING <br /> REQUIREMENTS OF THE LOCAL HEALTH DEPARTMENT <br />