Laserfiche WebLink
From 11(03/2008 15:36 #164 P 0161033 <br /> N7ED PROGRAM CONSOLIDATED FL. Al <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION--TANK INFORMATION(One form per USTNow on M ) <br /> TYPE OF ACTION (Check one item only. For an UST permanent closure or rWrloval,cotnplete only this section and Sections I,11,111,IV,and IX below) a3o <br /> �I NEW PP.RMIT � 3.RENEWAL PERMIT Q 5.CHANGE pF INFORMATION <br /> Q 6.TEMPORARY UST CLOSURE 7.UST PERMANENT CLOSURE pN SiTE S.US7 REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 4304 DATE$X[STING UST D1SCC+VERgD: 430b <br /> L FACILITY INFORMATION ��02 � <br /> FACILITY ID#(�igency(Ise Only) � � <br /> BUSINESS NAME(Same as FACI 11Y NAME or DBA-Doing Business As) d 3 <br /> BUSINESS SITE ADDRESS 103 CITY <br /> 104 <br /> II.TANK DESCRIPTION <br /> TANK ID# 432 TANK MANUFACTURER 433 TANK CONFIGURATION: THIS TANK IS 434 <br /> .A STAND-ALONE TANK <br /> 2.ONE INA COMPARTMENTED UNIT <br /> complete one Me for ch Mt in the unit <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY M GALLONS 435 NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> III.TANK USE AND CONTENTS <br /> TANK USE la MOTOR VEHICLE FUELING ❑ Ib.MARINA FUELING ❑ IC.AVIATION FUELING 439 <br /> ❑3.CHEMICAL PRODUCT STORAGE Q 4.HAZARDOUS WASTE(inetudes 1lsedoil) ❑5.EMERGENCY GENERATOR FUEL(HSC§23281 s(e)I <br /> ❑ 6.OTHER GENERATOR FUEL ❑95.UNKNOWN ❑ 99.OTHER (Specify): 4394 <br /> CONTENTS PETROLEUM: 19 is.REGULAR UNLEADED CS ❑ lo.MIDGRADE UNLEADED {] lb.PREMIUM UNLEADED J440❑3.DIESEL ❑ S.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL [ 9.OTHER PETROLEUM (S eif NON-PETROLEUM:❑ 7.USED OIL 10.ETHANOL <br /> ❑ 11.OTHERNON-PETROLEUM ecif):IV. TANK CONSTRUCTION <br /> TYPEOFTANK 1.SINGLE WALL 2.DOUBLE WALL 95.UNKNOWN 4 <br /> PRIMARY CONTAINMENT 1.STEEL 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER (Speci 4448 <br /> SECONDARY CONTAINMENT 0 1 STEEL 3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 443 <br /> 90_NONE ❑95.UNKNOWN [399* TUBEOTHER(S 'f)I 4434 <br /> OVERFILL PREVENTION 1.AUDIBLE&VISUAL ALARMS 2.BALL FLSHUT-OFF VALVE 452 <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION. 0 I.SINGLE-WALLED 2.DOUBLE-WALLED Q 99.Q71TR 1464c <br /> SYSTEM TYPE 1.PRESSURE ❑2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION 23 CCR¢2636(4x3)) <br /> PRIMARY CONTAINMENT 1.STEEL 4.FIBERGLASS ❑ 8.FLEXIBLE 10.RIGID PLASTIC <br /> ❑ 90.NONE ❑95.UNKNOWN ❑ 99.OTHER(Specify): <br /> SECONDARY CONTAINMENT ❑ 1 STEEL 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC <br /> ❑ 90.NONE [193.UNKNOWN ❑ 99.OTHER(Specify): <br /> PIPINGn URBINE CONTAINMENT SUMP TYPE ❑ 1.SINGLE WALL 2.DOUBLE WALL ❑ 90.NONE 4Md <br /> VI.VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENTPMMARY CONTAINMENT 1.STEE 15 4.FIBERGLASS 0 10.RIGID PLASTIC 040.NONE 99 ,OTHER(specify) 4648 <br /> 46481 <br /> VENT SECONDARY CONTAINMENT D I.STEEL 4.FIBERGLASS 0 10.RIGIDPLASTIC V.NONE ❑99,OTHER(Specify) 464f <br /> 464!1 <br /> VR PRIMARY CONTAINMENT 1 STEEL 10 4.FIBERGLASS 0 10.RIGID PLASTIC 90.NONE Lj 99.OTHER(Specify) 4645 <br /> aha r <br /> VIZ SECONDARY CONTAINMENT I.STEEL, 4.FIBERGLASS ❑ I0.RIGID PLAST)C ❑ 90.NONE ❑ 99.OTHER(Specify) 464h <br /> VENT PIPING TRANSITION SUMP TYPE 1,SINGLE WALL 2.DOUBLE WALL [1:3190,NONE 4644; <br /> RISER PRIMARY CONTAINMENT ❑ 1.STEEL IN 4.FIBERGLASS ❑ I Q.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464j <br /> RISER SECONDARY CONTAINMENT ❑ 1.STEEL 19 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 9D.NONE 94.OTHER(Specify) g6 I <br /> FILL COMPONENTS INSTALLED 1.SPILL BUCKET ❑ 3.STRfKER PLATE/BOTTOM PREC <br /> OTTOR V 47 464k1 <br /> CONTAINMENT SUMP 45ta•c <br /> VII.UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE ❑ 1.SINGLE WALL 2.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.NONE 469, <br /> CONSTRUCTION MATERIAL I.STEEL 4.FIBERGLASS 10.RIGID PLASTIC ❑99.OTHER(Swif) 469 c <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT J�6.ISOLATION aas <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true,accurate <br /> and In full compliance with legal reQukements. <br /> APPLICANT SIGNATURE JDATE 470 <br /> APPLICANT NAME(print) :aHAPPLICANT TITLE 47z <br />