Laserfiche WebLink
i <br /> HVAC ABBREVIATIONS MECHANICAL SYMBOLS MECHANICAL SYMBOLS MECHANICAL SHEET INDEX <br /> . _ . ._. PIPE ELBOW UP M0.1 MECHANICAL OVER SHEET � , <br /> AAV AUTOMATIC AIR VENT IiVAC HEATING/VENTILATION, AIR CONDITIONING SUPPLY DIFFUSER <br /> MO.2 TITLE 24 COMPLIANCE <br /> AC AIR CONDITIONING LAT LEAVING AIR TEMPERATURE � (ARROWS INDICATE_ THROW) (4 WAY SHOWN) ' <br /> .,..A_.R .__......._.m._.. PIPE ELBOW DOWN <br /> .1 HVAC PLACE <br /> ACCU AIF, COOLED CONDENSING UNIT l_VR LOUVER <br /> ACU AIR CONDI-(TONING UNIT LWT LEAVING WATER TEMPEFZATURERLRETURN GRI{_1...E- - �l .1 � �` L�� <br /> 1-7/1 KEY NOTES <br /> AFMS AIR FLOW MEASURING STATION MCA MINIMUM CIRCUIT AMPACI Y x&4.1 MECHANICAL SCHEDULES <br /> �� 4 XP DUST GRII_LR <br /> AFS AIR FLOW STATION MOCP MAXIMUM OVER CURRENT PROJECTION <br /> EF M5.1MECHANICAL DETAILS <br /> EQUIPMENT CALLOUS' (STANDARD} <br /> AHU AIR HANDLING UNIT OBD OPPOSED BLADE DAMPER1 <br /> APD AIR PRESSURE DROP OSA OUTSIDE AIR BOUND DUCT/FLUE(_UE THRU ROOF OR FLOOR ---3 { <br /> `� -- <br /> ASHRAE AMERICAN SOCIETY OF HFAIING, RA RETURN AIR f]�( FLEX DUCT F�Ev1s1Qr� <br /> REFRIGERATION, AND AIR CONDITIONING REG REGISTER <br /> u, <br /> T 'o u?v <br /> ENGINEERS RG RETURN AIR GRILLE SUPPLY DUCT THRU ROOF OR FLOOR ) (ROOM OR UNIT#) THERMOSTAT r t3 <br /> E3DD BACK DRAFT DAMPER S SMOKE DETECTOR <br /> J F OR FLOOR y(��1 CEILING--MOUNT TEMPERATURE SENSOR _-_____..__. ._____.__ _____._._.___ . ____._____ ___ __._.._____ ..____.___________________..__._.__. �.__.._ __.__.._. _..._ z °Q <br /> BOD BOTTOM OF DUCT SA SUPPLY AIR <br /> Ell :RETURN DUCT 1kIRl ROO yrs, ROOM OR UNIT 10 <br /> C6 70.F_ c" <br /> CD CEILING DIFFUSER SAG SUPPLY AIR GRILLE; 1 a z w H j�Z a r. <br /> CPR`SR COMPRESSOR SP STATIC PRESSUREL GENERAL NOTES � ! _�Do <br /> c o <br /> D13 DRY BUL(3 TEMPERATURE !.______._-_._ BALANCE DAMPER <br /> T THERMOSTAT"E R M O STAT _._._._._____,_.___._.,_,__MECH _._..__.___.._.._.__..__._. ___.._ _..__ __.,__,_-_,_____._.___,__.__._........__-__�..._._,_.___...___ ___.______ - <br /> i u w �2 w (u <br /> E)IFF DIFFUSER - - r��-,C u,J, <br /> ED TE..MPERA1lJRE DIFFERENCE L LINETYPES LEGENDcc.) a p a ET <br /> FA EXHAUST AIR � ' Fl <br /> TS TEMPERATURE SENSOR a,h_ .� "n ,_ <br /> SIDEl�AL_L O{� DOOR GRILLE � �_��,�' � `� <br /> ._.__.--____ --__-.____�__.___._.MECHANIC _..__.._.__..__.._-..__._____..__ _.___._.____._------------..__.--------__._._..__.. A. ALL WORK SHALL.. COMPLY WITH THE OWNERS REQUIREMENTS, AN[? WffEI A(_L APPLICABLE �, p- uj <br /> EAT ENTE�FiINC AIR 1E:MPE:RA(UfE� _ ` ' "� r " ' <br /> UH UNIT HEATER STATE AND LOCA(_ CODES, OR AUTHORITY HAVING JURISDICTION. 0,- � W � <br /> EF EXHAUST FAN UV UNIT VENTILATOR `�' > 6,c, <br /> SMOKE. DETECTOR (DUCT MOUNTED) B. PROVIDE SEISMIC RESTRAINT. FOR ALL PIPING EQUIPMENT, AND DUC-TWORK AS � �.�'c, , <br /> EG <br /> EXHAUST GRILLE VAV VARIABLE AIR VOLUME 44 <br /> _ CONDENSATE DRAIN RECOMMENDED IN SMACNA SEISMIC RESTRAINT MANUAL GUIDELINES FOR MECHANICAL cac�ca r� <br /> EWT ENTERING WATER TEMPERATURE VD VOLUME DAMPER SUPPLY AIR ELBOW UP EQUIPME"NT', LATEST" EDITION. CONSULT LOCAL_ SEISMIC CODES FOR THE SEISMIC RATING OF __ <br /> ca cxa E <br /> AN AREA IN WHICH THE PROJECT IS BEING BUILT, � � <br /> E:XI-1 EXHAUST WB WET BULB TEMPERATURE DIMENSION DESCRIPTION: « DUCT 00 <br /> X18 <br /> FUR FURNACE WC WATER COLUMN �> 1ST FIGURE SIDE SHOWN C. FOR LOW PRESSURE DUCTWORK, WHERE RECTANGULAR DUCT IS INDICATED ON PLANS, � <br /> 7.0 <br /> - SIDE NOT SFI()W'N EQUIVALENT SIZE ROUND DUCT MAY BE USED. EQUIVALENT SIZE RECTANGULAR DUCT MAY <br /> 2ND FIGURE — � MECHANICAL. EQUIPMENT <br /> MENT <br /> BE USED IN PLACE OF ROUND DUCT, EXCEPT IN EXPOSED AREAS, EQUIVALENT <br /> ALL_ SIZES IN INCHESTYPICAL_ cis <br /> (TYPICAL) RECTANGULAR SIZE MAY NOT BE USED ON DUCTS EXPOSED TO VIEW OR AS INDICATED <br /> i <br /> ROOF-TOP MECHANICAL. EQUIPMENTOTf1ERWISE. <br /> SUPPLY AIR ELBOW DOWN Z. <br /> D. HVAC CONTRACTOR IS RESPONSIBLE FOR COORDINATING FINAL LOC OF DIFFUSERS, < <br /> REGISTERS AND GRILLES WITH ARCHITECTURAL REFLECTED CEILING PLANS. CONTRACTOR <br /> _._._.._.---_._____._____.__------__.___...__GENERAL _________.__-__-____-.__-___.____.__.______._______.__.-_.._._..__.___.._ _ <br /> � RETURN AIR ELBOW UP SHAL(.- NOT DEVIATE FROM REFLE:C-TED CEIL..ING PLAN 11NLES0 THERE ARE E:XTENL)ATING JOB <br /> SITE. CONDITIONS. I <br /> AFF ABOVE FINISHED FLOOR KW KILOWAT1 /r ( ETURN A!R EL..E3OW DOWN F. DUCTWORK SIZES NOTED ON DRAWINGS ARE: FREE AREA SIZES. HVAC CONTRACTOR SHALL �— <br /> Al_ ALUMINUM MA MILLIAMPS BE RESPONSIBLE TO COMPENSATE FOR INSULATION, ETC. <br /> ALT ALTERNATIVE, ALTERNATE MAX MAXIMUM F. AL(_ SQUARE SUPPLY DIFFUSERS SHAL.L.. BE 4--WAY THROW UNLESS INDICATED OTHERWISE <br /> AP ACCESS PANEL MECH MECHANICAL 30- MAX ON PLAN. <br /> APPROX APPROXIMATE MFR MANUFACTURER 24°'x12 DOUBLE SIDE -TRANSITION G. PROVIDE TURNING VANES IN ALL MITERED ELBOWS AND F3UL.L.. HEAD TEES. <br /> 56 x12 <br /> AR ACID RESISTANT MIN MINIMUM ��_ .��. � "� <br /> }-l. SUBSTITUTIONS O{= EQUIPMENT 011-IER THAN AS SPECIFIED SHALL BE THE COMPLETE <br /> ARCH ARCHITECT, ARCHITECTURAL MTD MOUNTED (J° MAX RESPONSIBILITY OF THE HVAC CONTRACTOR. ANY ADDITIONAL ELECTRICAL, STRUCTURAL, <br /> ATMOS ATMOSPHERE NO/# NUMBE:.RMECHANICAL_ OR ARCHITECTURAL REQUIREMENTS SHALL BE:. PROVIDED ATNO ADDITIONAL_ <br /> i <br /> U'6'"x12" )4"x12"°' SINGLE SIDE TRANSITION EXPENSE TO OWNER, <br /> AUTO AUTOMATIC NOM NOMINAL <br /> BP-IP BRAKE HORSE POWER NTS NOT TO SCALE � <br /> I. COORDINATE INSTALLATION WITH -THE WORK OF OTHER TRADES PRIOR TO STARTING. IN THE <br /> BI DG BUILDING; OC ON CENTER ELBOW UPEVENT THAT CONFLICTS ARE FOUND Willi THE WORKOF OTHER ERADES, BRING AE..L_ SUCH <br /> ESOT BOTTOM OD OUTSIDE DIAMETER CONFLICTS TO THE ARCHITECT'SPROCEEDING ATTENTION FOR RESOLUTION PRIOR TO WIIFI <br /> THE WORK IN C CH <br /> COMMON OF'NG OPENING ELBOW DOWN VERIFICATIONS E <br /> NS SNADEFICIENCIES <br /> AIAT ARCORRFCTFDFAILURE CAUSED BY FO <br /> T NO ADD111C)NAL. EXPENSETORM IMMEDIATELY <br /> CFM CUBIC FEET PER MINUTE= PREFAB PREFABRICATED � NOTIFY ARCHITECT OF CONDITIONS IN CONFLICT WITH THE PLANS. <br /> wooi <br /> CL CENTERLINE PSF POUNDS PER SQUARE.: FOOT v� J. SEE SPECIFICATIONS FOR FURTHER REQUIREMENTS. <br /> DIA ELBOW - RADIUS (R) - 1.5 X DIA <br /> CLG CEILING PSI POUNDS PER SQUARE INCH <br /> POLYVINYL CHLORIDE- <br /> C,/W COORDINATE WITH PVC O -�- <br /> D DEPTH, DEEP R/RAD RADIUS R <br /> DIA/0 DIAMETER RE:. REFERENCE <br /> p <br /> I :,p W ELBOW - RADIUS (R) WIDTH � <br /> DWG DRAWING REO'D REQUIRED �m•.p 1 <br /> EFF EFFICIENCY RM ROOM <br /> E(.. ELEVATION RPM REVOLUTIONS PER MINUTE R <br /> ELEC ELECTRIC, ELECTRICAL SCHED SCHEDULE <br /> ELEV ELEVATOR SHT SHEET' <br /> ...:z:. 15* MAX <br /> EQUIP EQUIPMENT SPEC(S) SPECIFICATIONS) ,. SIZE <br /> EXT EXTERIOR SID STANDARD <br /> TRANSITION <br /> F FAHRENHEIT TEMP TEMPERATURE <br /> FIN FL/FF FINISHED FLOOR TYP TYPICAL <br /> FPM FEET PER MINUTE VEL VELOC',ITY "' <br /> �:` ��a .�..� SQUARE TO ROUND TRANSITION <br /> 1 <br /> FT FEET VFD VARIABLE FREQUENCY DRIVE <br /> FT HD FEET OF HEAD VIF VERIFY IN FIEI_.D <br /> ITP HOR SEPOWkLR W WIDE, WIDTH ACOUSTICALL.Y_.I_INED DUCTWORK I <br /> INSUL. INSULAIION, INSU(...ATE W/ WITIT <br /> I <br /> IN1 R INTERIOR W/0 WITHOUT <br /> \...., . DUCT DOWN <br /> �1-1R0„1_l,: DAM <br /> 08171 09-05-08 <br /> ['..<A,4'ti <br /> ANGLE TAKE—OFF i C'IaL(,,«_J <br /> DJ RSf <br /> I <br /> i <br /> I <br /> ! <br /> it <br /> T� <br /> MECHANICAL <br /> COVER SHEET <br /> i <br /> �M <br /> -' <br /> CV <br /> E <br /> N Q1 <br /> CV �. owl <br /> I r,� <br /> h� <br /> a ORIGINAL SHEET SIZE <br /> cs C? <br />