Laserfiche WebLink
REVISIONS <br /> FINISH SCHEDULE DOOR SCHEDULE <br /> DOOR FRAME <br /> ROOM FLOOR BASE WALLS CEILING REMARKS <br /> SIZE DETAIL FIRE RATING DOOR <br /> _ DOOR # LOCATION TYPE MATERIAL FINISH FRAME FRAME LABEL HARDWARE NOTES DOOR # <br /> z <br /> W H <br /> _ ' MATERIAL FINISH HEAD JAMB THRESHOLD <br /> Q <br /> z 0 0 0 0 1 FRONT ENTRY A 3'-0" 8'-0" ALUM/GLASS F ALUM. F 7/AD2 8/AD2 1 1 <br /> w <br /> ~ Z Z Z Z <br /> Lu o 2 FRONT EXIT A 3'-0" 8'-0" ALUM/GLASS F ALUM. F 7/AD2 - 8/AD2 1 2 <br /> 3 z p p p p 3 MARKET TO RESTROOM B 3'-0" 8'-0" WOOD PL METAL PL 5/AD2 5/AD2 - 2 3 <br /> r O J O J O Q O Q O 4 MARKET TO HALL C 3'-0" 7'-0" WOOD F METAL F 4 <br /> L = U O _j O_j O _j OLu E REAR EXIT(EXISTING) 3'-0" 7'-0" 3 E <br /> 3 QQ z Z >Q z Z >Q z Z >Q z Z z Z <br /> Q J > Q J > Q J > Q J Q J <br /> Z > w Z > w Z > w Z > w W p w <br /> Lu - - > - > - > - > <br /> Z Z Z <br /> Lu fn J Q U Q J Q U Q J Q U Q J Q U Q m Q <br /> z m w U „ J U „ J U � J U � J = Q J THIS DOCUMENT,AND THE IDEAS AND DESIGNS <br /> O w w N - Q - v> Q - v> � Q - � af Q V) w Q <br /> U v> J Q p w = p w p w p w p Q INCORPORATED HEREIN,AS AN INSTRUMENT OF <br /> p m ~ a° Q Q Z `n w O Q Q Z N w O Q Q Z O Q Q Z N O Q 3 Q <br /> r ,, O p U O p U O p U O p U O PROFESSIONAL SERVICE, IS THE PROPERTY OF <br /> w 01� af w Q J p n OL w Q J p n � w Q J p n w Q J p n p Z p <br /> z w � > m w z m w z m w z m w z m w a i AND IS NOT TO BE USED, IN WHOLE OR IN <br /> Lu m O U N O U � O U O U ik� N O P <br /> J ~ = U _ _ ~ = 3 = 3 ~ ~ N 3 _ _ ~ 3 � p <br /> NOTES: FINISH LEGEND <br /> Q = U N Q Q = U N Q Q = U N 0 Q = U N w 1 U WRITTEN AUTHORIZATION. <br /> r wo Q a w Q w Q w w Q w w <br /> p p p Q w w Q w w Q r w w Q >_ w w Q p O QSF STOREFRONT DOOR 3 HR 3 HOUR FIRE RATED F = FACTORY FINISH <br /> Lu Q < j j ~ C� _ _ _ `` C� _ _ `` C� _ _ `` C� Lu <br /> z Z <br /> Q w O O z o o z o _ o o z o 0 o z o 0 o z o w z DOOR ASSEMBLY <br /> N O U U U N °�° bo bo 00 Q bo °�° bo bo � Q 00 °�° ao bo °v° Q 00 °�° bo bo °v° Q bo °�° w Q SC = SELF CLOSER <br /> u) + + + + u) + + + < + + + + < + u) + + + + u) O S = FIELD STAIN <br /> KP=KICK PLATE AT PUSH SIDE. PLANNING ■ ■ ■ <br /> PB = PANIC BAR FP = FACTORY PRIME&FIELD FINISH <br /> MARKET <br /> 20 MIN. = 20 MIN.FIRE RATED PL =PLASTIC LAMINATE FINISH ARCHITECTURE <br /> 101 • • • • • • • <br /> DOOR ASSEMBLY <br /> 102 SEATING • • • • • • • FFP=FIELD PRIME&PAINT No <br /> 45 MIN = 45 MIN.FIRE RATED <br /> 103 CAFE • • • •• • 000 • DOOR ASSEMBLY <br /> 104 BAKERY • • • •• • •• •• 60 MIN = 60 MIN.FIRE RATED <br /> DOOR ASSEMBLY <br /> 105 WALK-IN COOLER • • • • • • • • • <br /> 90 MIN = 90 MIN.FIRE RATED <br /> O <br /> SCULLERY/PREP. • • • • • • • • • • • DOOR ASSEMBLY <br /> 106 <br /> 107 HALL • • • • • • LUS INC. <br /> • <br /> aiDi <br /> 108 STORAGE • • • • • • • <br /> 109 RESTROOM 0 0 0 0 0 • 0 0 335-BTN0 THESTAR WAY <br /> 110 CASHIER 0 0 0 0 0 0 MODESTO, CA 95356 <br /> ph. 209.577.4661 <br /> fx. 209.577.0213 <br /> www.apiarc.com <br /> FINISH NOTES DOOR TYPES SCALE: 1/4"= 1'-0" <br /> 1. DOORS TO BE FLUSH DESIGN WITH PLASTIC LAMINATE FINISH.SEE DOOR NOTES ON THIS SHEET <br /> FRANK C.BOOTS <br /> 2. PLASTIC LAMINATE CABINETS TO HAVE WHITE MELAMINE INTERIORS. CASEWORK JOSEPH L.SMITH <br /> 3. PAINT FINISH TO BE SEMI GLOSS ENAMEL. 1 -ALL CABINET WORK SHALL BE CONSTRUCTED TO W.I.C.CUSTOM GRADE RODNEY C.ALONZO <br /> 4. GYPSUM BOARD WALL TEXTURE TO BE VERY LIGHT STIPPLE FINISH. 2-CABINETS SHALL BE FLUSH OVERLAY CONSTRUCTION PROVIDE SIGN AT EGRESS ARCHITECTS <br /> 5. PAINT ALL VENTS AND REGISTERS IN SOFFITS/CEILINGS TO MATCH SOFFIT/CEILING COLOR. DOORS STATING"THIS DOOR TO Q <br /> 6. ACCESSIBLE SIGNAGE FOR RESTROOM TO BE BLACK WITH WHITE LETTERING (BLUE NOT ACCEPTABLE). 3-ALL INTERIOR SURFACES OF CABINET SHALL BE MELAMINE SURFACED REMAIN UNLOCKED WHENEVER V <br /> THE BUILDING IS OCCUPIED" <br /> 7. SEE PLUMBING DRAWINGS FOR ALL PLUMBING SELECTIONS. 4-ALL CABINET DOORS AND DRAWERS SHALL BE EDGE-BANDED <br /> 8. ELECTRICAL PLATES AND RECEPTACLES TO BE WHITE.SWITCHES TO BE DECORA STYLE,COLOR TO BE WHITE.SEE ELECTRICAL DRAWINGS FOR ADDITIONAL SPECIFICATIONS. ACCESSIBLE <br /> 5-PULLS SHALL BE 4"'WIRE PULL' RESTROOM `- <br /> 9. FLOOR,WALL AND CEILING MATERIAL SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS PER C.B.C.TABLE 803.9. SELF CLOSER SIGNAGE-MOUNT VIEW LITE <br /> l0. CONTRACTOR TO REPAIR ALL EXISTING FINISHES AS REQUIRED TO MATCH ADJACENT EXISTING FINISHES. 6-HINGES SHALL BE ADJUSTABLE INTERIOR TYPE,NON-VISIBLE WHEN DOORS ARE CLOSED 5-0"AFF To <br /> 11. GYPSUM BOARD TO BE 5/8"THICK.USE MOISTURE RESISTANT GYPSUM BOARD IN WET AREAS. 7-ADJUSTABLE SHELVING SHALL BE FINISHED WOOD WITH ADJUSTABLE HARDWARE DUAL PANE LOW E GLASS CENTERLINE <br /> A. 5/8"GYPSUM BOARD-TAPE,TEXTURE,PRIME,PAINT.PROVIDE LIGHT ORANGE PEEL FINISH-SUBMIT FULL SIZE SAMPLE/MOCK-UP FOR TENANT APPROVAL-TYPICAL CONSISTING OF RABBETED STANDARDS AND STEEL SHELF CLIPS-VERIFY FINISH AND '--.4HARDWARE od <br /> REQUIREMENTS WITH TENANTW U <br /> B. "USG,MOLD TOUGH"OR APPROVED EQUAL-5/8"MOISTURE RESISTANT GYPSUM BOARD-TAPE,TEXTURE,PAINT-PROVIDE LIGHT ORANGE PEEL FINISH- O N :* Lu <br /> 8-SUBMIT COLORS TO TENANT FOR APPROVAL SAFETY TEMPERED GLAZING PER H <br /> SUBMIT FULL SIZE SAMPLE/MOCKUP FOR TENANT APPROVAL-TYPICAL PAINT CBC 2406 / Q WW` <br /> C. "USG,DUROCK"OR APPROVED EQUAL-5/8"CEMENT BACKER BOARD AT TILE FINISH / N <br /> 12. RESTROOM ACCESSORIES SHALL BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR. 1 -PREMIUM 3 COAT PAINT SYSTEM T FLUSH PANEL DOOR W O QQ <br /> 13. SUSPENDED GRID CEILING SHALL BE 15/16"GRID WITH 24"x 48""VINYLROCK"OR OTHER APPROVED WASHABLE CEILING PANELS. (1)COAT PRIMER/SEALER ix <br /> 14. INTERIOR FINISHES OF ALL AREAS SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 200 AND SMOKE DEVELOPMENT RATINGOF 450(CLASS C) (2)COATS SEMI-GLOSS 5 <br /> 15. DECORATIVE MATERIALS,INCLUDING DRAPES AND HANGINGS,MUST BE NONCOMBUSTIBLE,FLAME RESISTANT OR TREATED WITH A FLAME RETARDANT PER CFC 2404.2 AND TITLE 19 SEC.3.06 NOTE: A B C a = W <br /> 1. PAINT COLORS TO BE APPLIED ON SAMPLE TEST AREA-OBTAIN <br /> 16. WALL AND CEILING PAINT IN STORAGE,CAFE,BAKERY,JANITOR,AND RESTROOMS SHALL BE SEMI-GLOSS. APPROVAL FROM TENANT PRIOR TO COMMENCING WORK. W <br /> 17. USE SCHLUTER STRIPS AT CHANGE OF FLOORING MATERIAL. Z <br /> N <br /> 18. AT AREAS OF OPEN CEILING,ALL EXPOSED ROOF FRAMING,ELECTRICAL CONDUIT,DUCTS,INSULATION,SOFFIT FRAMING,ECT.SHALL BE PAINTED. Q W <br /> 19. ALL COVE BASE MATERIAL TO HAVE MINIMUM 3/8"RADIUS. ZLu N <br /> H N <br /> Z <br /> WINDOW TYPES SCALE: 1/4"= 1'-0" DOOR HARDWARE DOOR NOTES ° <br /> EXISTING ALUMINUMBUILDING DEPARTMENT NOTES: <br /> STOREFRONT ASSEMBLY HARDWARE GROUPS: <br /> 1. LOCKSET-HARDWARE BY STOREFRONT MANUFACTURER-PROVIDE DEADBOLT LOCKABLE HARDWARE,PUSH/PULL ON l. ALL EXITS ARE TO BE OPERABLE FROM INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE. <br /> EXTERIOR,SELF CLOSER,CONTINUOUS HINGE,THRESHOLD,DRIP CAP,WEATHER STRIPPING(TO FIT),DOOR SWEEP DOOR STOP, Lu <br /> 2. ALL HAND ACTIVATED DOOR HARDWARE TO BE CENTERED BETWEEN 34"AND 44"A.F.F.AND BE LEVER, J <br /> SIGN OVER DOOR TO READ'THIS DOOR..:' PANIC-BAR OR PUSH/PULL PER CBC 11 B404.2.7 AND 11 B-309.4. Lu <br /> D <br /> 2. LEVER LOCK SET(ANSI F76 PRIVACY FUNCTION), 1.5 PR HINGES,CLOSER,WALL STOP,INTERIOR DOOR SWEEP(FOR 3. THE LOWER 10"OF ALL DOORS SHALL COMPLY WITH CBC 116404.2.10. U <br /> ACOUSTICS),ACCESSIBLE SIGNAGE,SILENCERS (STRIKE SIDE) V) <br /> 3. ALL HARDWARE IS EXISTING AND ACCESSIBLE:REAR DOOR HAS RIM EXIT DEVICE 4. ALL DOORS TO HAVE MINIMUM 18"STRIKE SIDE CLEARANCE AT INTERIOR AND 24"AT EXTERIOR. <br /> T T T EXISTING ALUMINUM T TL T Z <br /> STOREFRONT ASSEMBLY 5. MAXIMUM EFFORT TO OPERATE DOORS SHALL BE NOT GREATER THAN: <br /> 4. ALL HARDWARE BY DOOR MANUFACTURER 5LB AT EXTERIOR DOORS,5LB AT INTERIOR DOORS AND 15LB AT FIRE DOORS PER CBC 118404.2.9. <br /> Z <br /> NEW ALUMINUM Q <br /> STOREFRONT ASSEMBLY NEW ALUMINUM 6. PROVIDE SIGN AT ENTRY DOORS STATING"THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED" <br /> STOREFRONT ASSEMBLY <br /> WITH DUAL PANE NOTE: <br /> WITH DUAL PANE 7. DOOR CLOSERS AND GATE CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90 DEGREES,THE TIME O <br /> TEMPERED GLAZING <br /> TEMPERED GLAZING \/ \/ HARDWARE FINISH: 0 <br /> OIL RUBBED BRONZE-VERIFY WITH TENANT REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 SECONDS MINIMUM. Z <br /> co bo 8. DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO THAT FROM THE OPEN POSITION OF 70 DEGREES,THE DOOR OR <br /> /\ INDICATES SAFETY /\ INDICATES SAFETY GATE SHALL MOVE TO THE CLOSED POSITION IN 1.5 SECONDS MINIMUM. O <br /> TEMPERED TEMPERED <br /> 7 / \ GLAZING PER CBC / \ 9 GLAZING PER CBC 9. THE INTERIOR DOORS TO ALL UNCONDITIONED ROOMS SHALL HAVE FULL WEATHER SEALS AT THE DOOR ASSEMBLIES Q <br /> AD2SEC.2406& AD2 SEC.2406& <br /> 704.3.2.3 704.3.2.3 10. THE LEVER OF LEVER ACUTUATED LATCHES OR LOCKS SHALL BE CURVED WITH A RETURN TO WITHIN 1/2 INCH OF THE DOOR <br /> T T T T T T TO PREVENT CATCHING ON THE CLOTHING OF PERSONS DURING EGRESS CBC 1010.1.9.1. <br /> ±1'-1 V , 3'-0" EXISITNG EXISTING , EXISTING , 3'-0" 13'-0" EXISTING <br /> NEW NEW DOOR NOTES / SPECIFICATIONS: <br /> A B 1. INTERIOR SOLID CORE WOOD DOORS:"T.M.COBB"OR APPROVED EQUAL 1 3/4"THICK WITH PLASTIC LAMINATE:WILSONART- <br /> EXTERIOR STOREFRONT EXTERIOR STOREFRONT <br /> VERIFY SELECTION WITH TENANT. <br /> AD2 4) <br /> 2. INTERIOR METAL DOOR FRAMES:"WESTERN INTEGRATED"SERIES 300 OR 400 AS APPROPRIATE OR APPROVED EQUAL-FINISH TO BE <br /> g_p FACTORY BRONZE ANODIZED. o <br /> m <br /> 3. VERIFY ALL HARDWARE FINISHES WITH TENANT. <br /> "WESTERN INTEGRATED"WINDOW FRAME NOTE: 4. VERIFY ALL DOOR STYLES AND MATERIALS WITH TENANT. <br /> TO MATCH DOORS WINDOW AND STOREFRONT MANUFACTURERS <br /> TO SUBMIT SHOP DRAWINGS FOR APPROVAL 5. ELIASON DOOR:SCP-3 STAINLESS STEEL TRAFFIC DOOR. N <br /> PRIOR TO FABRICATION-TYPICAL <br /> 0 <br /> C? GLASS IN LOCATIONS SUBJECT TO HUMAN M <br /> EXTERIOR STOREFRONT PERFORMANCE REQUIREMENTS: IMPACT SHALL BE TEMPERED PER CBC 2406 DATE : FEBRUARY 2020 a <br /> FIELD VERIFY ALL DIMENSIONS W/EXISTING U <br /> SHGC: aJOB NO. : 19-130 <br /> STOREFRONT SYSTEM: .32 T OPENING o <br /> INDICATES SAFETY TEMPERED GLAZING PER INTERIOR WINDOW SYSTEM FINISH:CLEAR DRAWN : A. ZAPIEN <br /> U-FACTOR: CBC SEC.2406&704.3.2.3 ANODIZED CHECKED : J. SMITH <br /> STOREFRONT SYSTEM: 40 0 <br /> 1/4"CLEAR GLAZING-TYPICAL AT INTERIOR <br /> UNLESS OTHERWISE NOTED SHEET : E <br /> VLT: 1"DUAL PANE INSULATED GLAZING-"VISTA o <br /> STOREFRONT SYSTEM: .50 WALL"-SERIES 3000-S THERMAL SYSTEM <br /> FINISH:CLEAR ANODIZED <br /> ALL WINDOWS AND DOORS SHALL BE NFRC RATED TYPICAL AT EXTERIOR <br /> C <br /> INTERIOR STOREFRONT A5o0c' <br /> 0 <br /> / <br /> 0 <br /> P <br /> api COPYRIGHT 2019 <br />