My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
RIVER
>
222
>
1600 - Food Program
>
PR0546365
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2021 8:09:40 AM
Creation date
12/17/2020 3:21:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546365
PE
1624
FACILITY_ID
FA0026275
FACILITY_NAME
KLEAN EATZ MARKET & BAKERY
STREET_NUMBER
222
Direction
W
STREET_NAME
RIVER
STREET_TYPE
RD
City
RIPON
Zip
95366
CURRENT_STATUS
01
SITE_LOCATION
222 W RIVER RD
P_LOCATION
05
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REVISIONS <br /> DESCRIPTION DATE: <br /> DuctWork 41 Side View DuctWork #1 SE View <br /> 0 <br /> 0 <br /> 0 <br /> oil <br /> 23.50 REDUCED CLEARANCE B <br /> DETAIL <br /> 3/4' REDUCED I I cc <br /> N <br /> CLEARANCE I <br /> II E <br /> d <br /> Exh Curb (+23600"AEE) <br /> 104 <br /> EXHAUST FAN. ,��56.5'MAX ss;,%s"firI9"MIN HIGH TEMP GASKET IS USED '%T❑ SEAL THE FAN T❑ THE '"��ROOF 21600"AEE) TRANSITION PLATE ',,�s"s;;siif ss I I W <br /> 7 <br /> COMBUSTIBLE I U? <br /> THE INNER DUCT IS FULLY WELDED u- <br /> TO THE TRANSITION PLATE, ALL SURFACE 04 <br /> N <br /> WELDS ARE DYE TESTED. N <br /> DOUBLE V-BAND <br /> 92 5'MAX <br /> rn <br /> 75' x <br /> 55'MIN - DUCT a Q <br /> _ 1 0 <br /> VENTED CURB i N <br /> ROOF TERMINATION ++ <br /> FACTDRY BUILT DDUBLE WALL GREASE DUCT MDDEL DW-2R SPECIFICATION, i1_, <br /> FURNISH DOUBLE WALL,FACTGRY BUILT GREASE DUCT FOR USE WITH TYPE 1 KITCHEN , W <br /> V HOODS,WHICH CONFORMS TO THE REQUIREMENTS OF NFPA-96. PRODUCTS SHALL BE ETL v <br /> OJ LISTED TO UL-1978 AND UL-2221 FOR VENTING AIR AND GREASE VAPORS FROM I <br /> AND AC101 DUE <br /> OPERATION. TESTING HAS BEEN EXTENDED TO AND <br /> 3Z IAR ASTM E2336 <br /> AND ACI01 DUE TO SIMILAR TESTING CRITERIA. MODELS DW-2R, I AND S ARE USED FOR Lij <br /> z <br /> GREASE DUCT ATANDARD FOR <br /> WHEN INSTALLED IN L AND FIRE WITH THESE INSTRUCTIONS Z <br /> AN NEPA 96;STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL <br /> COOKING OPERATIONS. DOUBLE WALL GREASE DUCTS ARE LISTED FOR A CONTINUOUS <br /> INTERNAL TEMPERATURE OF 500 DEGREES F AND INTERMITTENT TEMPERATURES OF 2000 = <br /> SECURED TO THE DEGREES F. I d <br /> THE DUCT SECTIONS SHALL BE CONSTRUCTED OF AN INNER DUCT WALL AND AN OUTER O <br /> CURB BY OTHER. WALL WITH INSULATION IN BETWEEN. THE INNER DUCT WALL SHALL BE CONSTRUCTED OF <br /> .036 INCH THINK,430 TYPE STAINLESS STEEL AND BE AVAILABLE IN DIAMETERS 8' p <br /> THROUGH24'. THE OUTER WALL SHALL BE CONSTRUCTED OF STAINLESS STEEL AT A <br /> MINIMUM NF,024 INCH THICKNESS, THE DUCT,BASED ON MG➢EL NUMBER,SHALL INCLUDE <br /> LAYERS OF SUPER WOOL 607 PLUS INSULATION BETWEEN THE INNER AND OUTER WALL. <br /> GREASE DUCT JOINTS SHALL BE HELD TOGETHER BY MEANS OF FORMED V CLAMPS AND Q <br /> SEALED WITH 3M FIRE BARRIER 2000+. THE DUCT WALL ASSEMBLY SHALL HE TESTED AT 0 <br /> 3/4'0R ZERO INCH CLEARANCE,ACCORDING TO CLASSIFICATIONS, <br /> CLASSIFICATIONS AND CLEARANCES N <br /> UL 2221: STANDARD FOR FIRE RESISTIVE GREASE DUCT ENCLOSURE ASSEMBLIES. CHAPTER @ <br /> 7 OF THIS STANDARD REFERENCES A TEST LABELED INTERNAL FIRE TEST,SECTION 7.1.1 <br /> LISTED PRFAIF DUCT. REFERENCES TWO INSTALLATION CONDITIONS,CONDITION A AND CONDITION B. CONDITION A <br /> REPRESENTS ALL INSTALLATION CONDITION EXCEPT FOR INSTALLATION WITHIN - <br /> NON-VENTILATEDCOMBUSTIBLE ENCLOSURES. CONDITION B REPRESENTS INSTALLATION - <br /> WITHIN A NON-VENTILATED COMBUSTIBLE ENCLOSURE. m <br /> In MODEL DW-2R IS CLASSIFIED UNDER UL2221 AS AN ALTERNATE TO 2-HR FIRE RESISTIVE <br /> SHAFT ENCLOSURES WITH A REDUCED CLEARANCE TO COMBUSTIBLES(SIZES 8'TO 16' <br /> DIAMETER). MODEL 2R IS LISTED IN ACCORDANCE WITH THE REQUIREMENTS FOR DUCT 0 <br /> (U ENCLOSURE CONDITION B. U <br /> Sof <br /> + (` g 1 3 2 0 0 MODEL DW-2R 3/4'CLEARANCE TO COMBUSTIBLES FROM THE SURFACE OF THE DUCT OUTER 0 <br /> SHELL; ZEROR INCH CLEARANCE FROM COMBUSTIBLES FROM THE TIP OF THE OUTER V ,C <br /> BAND. <br /> V <br /> DOUBLE WALL GREASE DUCT SHALL BE INSTALLED IN ACCURDANCE WITH THE Q <br /> MANUFACTURER'S'INSTALLATION,OPERATION AND MAINTENANCE MANUAL;ELL LISTING, 00 <br /> STATE AND LOCAL CODES, FANS SHALL BE SUPPORTED INDEPENDENTLY FROM THE GREASE <br /> DUCT SECTIONS. PROTECT GREASE DUCT FROM TWISTING OR MOVEMENT CAUSED BY FAN <br /> TORQUE OR VIBRATION. <br /> CERTIFICATIONS <br /> THE DW-2R SERIES HAS BEEN CERTIFIED BY ITS. THIS CERTIFICATION MARK INDICATES <br /> THAT THE PRODUCT HAS BEEN TESTED TO AND HAS MET THE MINIUM REQUIREMENTS OF A <br /> WIDELY RECOGNIZED(CONSENSUS)U.S.AND CANABIAN PRODUCTS SAFETY STANDARD,THAT <br /> THE MANUFACTURING SITE HAS BEEN AUDITED,AND THAT THE APPLICANT HAS AGRRED TO A <br /> PROGRAM OF PERIODIC FACTORY FOLLOW-UP INSPECTIONS TO VERIFY CONTINUED <br /> PERFORMANCE. <br /> 2R 06 <br /> L) <br /> Ll <br /> 65.5'MAX <br /> 53' <br /> 39"MIN <br /> Q <br /> ® GREASE DUCT & CHIMNEY SPECIPICATI❑NS o <br /> PR❑VIDE GREASE DUCT EQUAL- TO CAPTIVEAIRE SYSTEMS Y❑DEL- "DW// <br /> R❑UND 20 GAUGE 430 STAINLESS STEEL DUCTW❑RK YUDEL "DW" LL] `o <br /> IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP LOCKING <br /> C❑NNECTI❑NS SEALED WITH 3Y PIRE BARRIER 2000 PLUS Y❑DEL "DW" N <br /> D❑ES NCT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER Q <br /> THE YANUPACTURES INSTALLATI❑N GUIDE W <br /> PR❑VIDE RATED ACCESS D❑❑RS AT EVERY CHANGE IN DIRECTI❑N AND EVERY 12' ❑N CENTER. W <br /> PER YANUPACTURES LISTING YUDEL "DW" HURIZ❑NTAL RUNS LESS THAN 75 PT CAN BE Q 3 0 <br /> SL❑PED 1/16" PER 12", H❑RIZ❑NTAL RUNS Y❑RE THAN 75 PT, CAN BE SL❑PED 3/16" PER 12". J a_ <br /> cu <br /> DUCT SH❑ULD BE SL❑PED AS MUCH AS PUSSIBLE TU REDUCE THE CHANCE UP GREASE <br /> ACCUYULATI❑N IN H❑RIZ❑NTAL RUNS <br /> DATE: 3/12/2020 <br /> IP THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF C❑YBUSTIBLE MATERIAL, PR❑VIDE DWG'#: <br /> Floor (+0,00"AEE) 4284251 <br /> UL-2221 ❑R UL-103 HT LISTED D❑UBLE WALL GREASE DUCT ❑R D❑UBLE WALL CHIMNEY <br /> WN <br /> EQUAL TO CAPTIVEAIRE SYSTEMS YODEL "DW- 2R, 2R TYPE HT, 3R, FIR 3Z" ROUND 20 GAUGE DRABY: <br /> 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE 430 STAINLESS UUTER SHELL SCALE: <br /> DEMONSTRATIONS ARE AVAILABLE AT THE 3/4" = 1'-0" <br /> CALIFORNIA <br /> P ICESAANDREA Q QUESTIONS, CALL CUSTOMER <br /> CUSTOMER APPROVAL TO MANUFACTURE. MASTER DRAWING <br /> REFERENCE JOB#4284251 Approved as Noted ❑ <br /> PWM (4= 956-2200 FAX (919) 227-5940 Approved with NO Exception Taken ❑ <br /> Revise and Resubmit ❑ <br /> SIGNATURE SHEET NO. <br /> 7 <br /> Your Title Date <br /> IM <br /> = 30 <br /> 3 w = or <br /> Q N � IM O <br /> X CC <br /> N N 2- C Z co <br /> CQ <br /> CSO co - Q I) <br /> I n Z N <br /> W W v <br /> m m No <br /> (n � (' � o <br /> ' <br /> 07 00 OC) (n Z o <br /> (Q 00 c N (D � CI S <br /> o O CQ <br /> < Z3 Z <br /> C <br /> N 0 <br /> N <br /> O_ rh <br /> CD <br /> O <br /> _ nu O 0 CAPTIVEAIRE DRAWINGS ::EQ z <br /> D D <br /> �2_ > n m <br /> M M D rn iC7 � -n 0 0 <br /> Z O (� z0zSQ 0 <br /> M �S ?h'O w > _ Doo ° � <br /> Cyd FFs Cn n D 0 ' zmz <br /> 0 D w > �, 0 KLEAN EATZ X C) Z M z oA °mz <br /> O o <br /> o D TENANT IMPROVEMENT o N� N ^ Z <br /> • O No <� o Do ` s Op = rn rn V' n- mzD <br /> N '`� �� C 222 WEST RIVER ROAD, SUITE C & D m ° z Q �O 'O (" Z z <br /> _ O� �`� ° � mz � (n nD � � � � = ° � D <br /> n� °= n A( <br /> m "O <0N0 n <br /> z o N W Z 0OmCN <br /> N 1 0 <br /> RIPON CA 0 � � � ZoN0S <br /> M:\JOBS\2020 Jobs\2020-010 Ripon Organic Market-Klean Eatz\2020-010 HVACPlumb.dwg 3-16-20 09:21:00 AM c-pc <br />