My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0013833
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AHERN
>
29700
>
2600 - Land Use Program
>
PA-1600049
>
SU0013833
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2024 8:33:36 AM
Creation date
12/21/2020 4:16:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0013833
PE
2627
FACILITY_NAME
PA-1600049
STREET_NUMBER
29700
Direction
S
STREET_NAME
AHERN
STREET_TYPE
RD
City
TRACY
Zip
95304-
APN
25502014
ENTERED_DATE
12/21/2020 12:00:00 AM
SITE_LOCATION
29700 S AHERN RD
RECEIVED_DATE
8/31/2022 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
W b LI <br /> 001 <br /> m a on ho <br /> C ¢ '3 <br /> i <br /> 1411 <br /> Attachment 2 — Electric Facilities <br /> It is PG & E ' s policy to permit certain uses on a case by case basis within its electric <br /> transmission fee strip (s) and/or easement(s) provided such uses and manner in which they are <br /> exercised , will not interfere with PG & E ' s rights or endanger its facilities . Some <br /> examples/restrictions are as follows : <br /> 1 . Buildings and Other Structures : No buildings or other structures including the foot print and <br /> eave of any buildings , swimming pools , wells or similar structures will be permitted within fee <br /> strip(s) and/or easement(s) areas . PG & E ' s transmission easement shall be designated on <br /> subdivision /parcel reaps as " RESTRICTED USE AREA — NO BUILDING . " <br /> 2 . Grading : Cuts , trenches or excavations may not be made within 25 feet of our towers . <br /> Developers must submit grading plans and site development plans ( including geotechnical <br /> reports if applicable) , signed and dated , for PG & E' s review. PG & E engineers must review grade <br /> changes in the vicinity of our towers . No fills will be allowed which would impair ground4o- <br /> conductor clearances . Towers shall not be left on mounds without adequate road access to <br /> base of tower or structure . <br /> 3 . Fences : Malls , fences , and other structures must be installed at locations that do not affect <br /> the safe operation of PG &' s facilities , Heavy equipment access to our facilities must be <br /> maintained at all times . Metal fences are to be grounded to PG & E specifications . No wall , fence <br /> or other like structure is to be installed within 10 feet of tower footings and unrestricted access <br /> must be maintained from a tower structure to the nearest street . Walls , fences and other <br /> structures proposed along or within the fee strip (s) and/or easement(s) will require PG & E <br /> review ; submit plans to PG & E Centralized Review Team for review and comment . <br /> 4 . Landscaping : Vegetation may be allowed ; subject to review of plans . On overhead electric <br /> transmission fee strip (s ) and /or easement( s) , trees and shrubs are limited to these varieties that <br /> do not exceed 15 feet in height at maturity . PG & E must have access to its facilities at all times , <br /> including access by heavy equipment . No planting is to occur within the footprint of the tower <br /> legs . Greenbelts are encouraged . <br /> 5 . Reservoirs , Sumps , Drainage Basins , and Ponds : Prohibited within PG & E' s fee strip (s) <br /> and/or easement(s) for electric transmission lines . <br /> 6 . Automobile Parking : Short terra parking of movable passenger vehicles and light trucks <br /> ( pickups , vans , etc . ) is allowed . The lighting within these parking areas will need to be reviewed <br /> by PG & E ; approval will be on a case by case basis . Heavy equipment access to PG & E facilities <br /> is to be maintained at all times . Parking is to clear PG & E structures by at least 10 feet . <br /> Protection of PG & E facilities from vehicular traffic is to be provided at developer' s expense AND <br /> to PG & E specifications . Blocked - up vehicles are not allowed . Carports , canopies , or awnings <br /> are not allowed . <br /> 7 . Storage of Flammable , Explosive or Corrosive Mater als : There shall be no storage of fuel or <br /> combustibles and no fueling off vehicles within PG &E' s easement. No trash bins or incinerators <br /> are allowed . <br /> 8 . Streets and Roads : Access to facilities to be maintained at all times . Street lights may be <br /> allowed in the fee strip (s) and /or easement (s) but in all cases must be reviewed by PG & E for <br /> PG &E Gas and Electric Facilities Page 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.