Laserfiche WebLink
DEVELOPMENT DATA <br /> N 49°21'08" E 240.00' <br /> _ — ASSESSOR'S PARCEL NUMBER: 255-020-14 RVI,'Zi��ED SITE P LAN <br /> - - o Q ADJACENT PARCEL PROJECT ADDRESS: 29700 S. AHERN ROAD rs�1 , <br /> '° �—'` � . U TRACY, CA 95304 al C% .. <br /> w Q 0- <br /> 0 <br /> 255-20-150 N. <br /> ,Ro •....�� `\ 1 PROJECT JURISDICTION: SAN JOAQUIN COUNTY -- "" - <br /> - STA - <br /> N 59SCOPE OF WORK: USE PERMIT APPLICATION FOR THE DEVELOPMENT OF''THE' <br /> Pp o 3g 05" VACANT PROJECT SITE INTO A PROPOSED TRUCK STOP, 1 <br /> 803.gg'(R TRUCK WASH, FUELING STORAGE BUILDING, GAS <br /> MlletOe <br /> STATION, AND CONVENIENCE STORE. <br /> o QRg® 4GENERAL PLAN DESIGNATION: C/FS Associates <br /> <o DIESEL 4 <br /> FUEL CANOPY _ <br /> 5,940 SF g _ -�.� ZONING C-FS <br /> _ :-... Ing agln e ening <br /> ® � SITE AREA: 9.49 ACRES / 413,384 SFa California Corporation <br /> WATER SERVICES PRIVATE, ON SITE WELL <br /> BUILDING 2 j WASTE SERVICES: PRIVATE, ON SITE SEPTIC <br /> ❑ <br /> FUEL TANK 1000 LINCOLN ROAD SUITE H2O2 <br /> L.L I A BUILDING 3 STORAGE BLDG. / FIRE SPRINKLERS: PRIVATE, ON SITE WATER STORAGE TANKS PYA CITY, CALIFORNIA 95991 <br /> Y. <br /> 3,500 SF <br /> 7 / BUILDING AREA, USE & PARKING: BUILDING 1 h m <br /> I RUCK WASH13,412 SF <br /> Z o o a j <br /> CENTER j USER, TRUCK STOP GAS STATION <br /> � ON-:SITE 530 75� ��� � ,I <br /> ' ( 530-75 <br /> TRUCK SALES & SERVICES - STOP �f". <br /> ruKING PLOYEE 00 � o � oo SANLTARY SEWER PAR <br /> W I LEACH, FIELD 4 PER 1000 SF + .67 PER EM <br /> 2:2 'AC / _ (4 x 14) + (.67 x 15 EMPLOYEES) <br /> I <br /> i ' o I 2 75'-0" = 66 SPACES REQUIRED JULIO J. TINAJERO <br /> Q Ln 40'-0" 203'-7" 80'-0" DRIVE 75'-0" 75 -0" LEAD DESIGNER <br /> BUILDING 2 <br /> AREA: 2,032 SF CHRISTOPHER L. DAY, P.E. <br /> USE: FUEL STORAGE BUILDING PROJECT ENGINEER <br /> `V - PARKING: ACCESSORY BUILDING TO FUELING STATIONS <br /> U.G. .STORM DRAIN SYSTEM NO PARKING REQUIRED <br /> ~ �szaA_ ARE A <br /> w o •S,Aq s;„AR NON-OCCUPIED BUILDINGCn <br /> STAMP: <br /> LJ <br /> 00\� z I•��'00� BUILDING 3 OFESSI <br /> a ¢ z a o��,� ��o � AREA: 3,500 SF ��4R O�r9l <br /> M a J USE: TRUCK WASH (2 BAYS) <br /> PARKING. NO PARKING REQUIRED �H�R/�IST DAE <br /> z a�*ate - - - .•/ C'J LLV 1 C� <br /> 0 w ti CHRISTOPHER <br /> ` DIESEL FUEL CANOPY No. C 64309 <br /> ./ AREA: 5,940 SF * exp. 6/30/21 <br /> USE: FUEL CANOPY <br /> �•/ PARKING: NO PARKING REQUIRED CI VIti Q <br /> - - - - - - - - - - - O �// FUEL CANOPY OF CALZ� <br /> 30'-0" — — — — — — — /— — i �O � / AREA: 7,200 SF <br /> 'L' j' DRIVE / 1, �j USE: FUEL CANOPY <br /> 4 PARKING: NO PARKING REQUIRED <br /> 10 / / `� �� SUBMITTAL DATE <br /> I 3 <br /> TAL BUILDING AREA PROPOSED: 22,664 SF <br /> .TQPLANNING DEPT: 05-01 -19 <br /> v <br /> 10 8 BUND G 1 ; ,� \ �•// / TOTAL PARKING REQUIRED: 66 STANDARD SPACES BUILDING DEPT: <br /> 13 412 SF L--- / 27 TRUCK SPACES , <br /> t / PUBLIC WORKS: <br /> o� o� SURVEY: <br /> C' <br /> 1 AS STATION & TRUCK STP 6 / \� \ ��i <br /> PARKING PROVIDED: BUILDING 1 67 <br /> STANDARD SPACES: 65 <br /> o 001 27 / : �� / ACCESSIBLE SPACES: 2 <br /> CAR FUELING: 16 REVISIONS <br /> TRUCK FUELING: 10 <br /> o I L 6 ,`�; n �1C 1 ` BUILDING 2 0 No. Description Date <br /> 17 7 FUEL CANOPY �/ / STANDARD SPACES: 0 <br /> o 7,200 SF ACCESSIBLE SPACES: 0 <br /> SITE PLAN REVISION 09/16/20 <br /> ° 0'�� W��2 g0 <br /> BUILDING 3 4 <br /> 35 STANDARD SPACES: 3 <br /> ACCESSIBLE SPACES: 1 , <br /> 417. 4' <br /> / TOTAL <br /> NORTH STANDARD SPACES: 68 <br /> ACCESSIBLE SPACES: 3 ^ <br /> GCAR <br /> TRUCK FUELING: 10 <br /> SITE PLAN TRUCK PARKING: 27 Q <br /> / SCALE: 1" = 50'-0" TOTAL CAR SPACES PROVIDED: 71 Q <br /> TOTAL TRUCK SPACES PROVIDED: 27 <br /> Z / / O <br /> SITE AREA TABULATIONS: BUILDING AREA: 22,664 SF 5% zC0 O <br /> LANDSCAPE AREA: 53,136 SF 13% W V <br /> CONCRETE / ASPHALT AREA: 337,584 SF 82% C V z <br /> ® KEYNOTES PRO .J E C T TEAM VICINITY MAP TOTAL SITE AREA: 413,384 SF _ — 0 <br /> O Cl) O <br /> O PROPERTY LINE, TYPICAL PROPERTY OWNER DESIGN FIRM WATER SERVICES: PRIVATE WELL w (D cr <br /> 0 DASHED 'LINE INDICATES LINE OF DIESEL FUEL CANOPY ABOVE - 22'-0" x 270'-0" PAREE ENTERPRISES, INC. MILESTONE ASSOCIATES SANITARY SEWER SERVICES: ON-SITE LEACH FIELD W z - z 0 <br /> CHARANJIT CJ JUTLA JULIO TINAJERO w r <br /> O3 Ir <br /> CMU TRASH ENCLOSURE , TYPICAL 3940 N. TRACY BOULEVARD 1000 LINCOLN ROAD, STE. H2O2 �, LINN ROAD STORM WATER COLLECTION_ UNDERGROUND W � <br /> T TRACY, CA 95304 YUBA CITY, CA 95991 oGTy q w G \ _ = 0 0 <br /> (D SAN JOAQUIN STANDARD PARKING STALL PH. (209) 832-5006 PH. (530) 755-4700 0 <br /> 9'-0" WIDE x 20'-0" LONG FAX (209) 832-5307 FAX (530) 755-4567 F�Ati z <br /> '� I- Q Q O <br /> SAN JOAQUIN STANDARD TRUCK PARKING STALL W W' 90 Q V <br /> 15'-0" WIDE x 70'-0" LONG WITH OVERHEAD CLEARANCE OF 14' 0" �' <br /> -� JIB fn � L0 <br /> � N <br /> O6 LOCATION OF EXISTING DOMESTIC WATER WELL <br /> OLW 00 (� Z <br /> O7 ASPHALT PAVING, TYPICAL W <br /> a O � ~ � <br /> ~ OC Q 0) <br /> O8 VAN ACCESSIBLE PARKING STALL, TYPICAL D <br /> LEHM N ROA � �— �— N <br /> O9 CONCRETE WALK, TYPICAL U 0 <br /> o Q <br /> Q � o <br /> It <br /> 10 DASHED LINE INDICATES LINE OF FUEL CANOPY ABOVE - 60'-0" x 120'-0" DRAWING INDEX 0 <br /> u <br /> 11 FUTURE DRIVE-THRU LANE . m o <br /> DATE: 09-16-20 <br /> ARCHITECTURAL <br /> DD1 SITE PLAN, DEVELOPMENT DATA SCALE: 1" = 50' <br /> DRAFTER: STAFF <br /> JOB NUMBER: 17-973 <br /> NORTH <br /> PROJECT LOCATION <br /> 29700 S. AHERN ROAD SHEET: <br /> TRACY, CA 95304 <br /> A.P.N.: 255-020-14 <br /> DD1 <br /> ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF MILESTONE ASSOCIATES IMAGINEERING, INC., AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF MILESTONE ASSOCIATES IMAGINEERING, INC. C2220 MILESTONE ASSOCIATES IMAGINEERING, INC. ALL RIGHTS RESERVED. <br />