My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WP0041382
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Z
>
ZUCKERMAN
>
2121
>
4200/4300 - Liquid Waste/Water Well Permits
>
WP0041382
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2020 2:38:23 PM
Creation date
12/23/2020 2:36:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
WP0041382
PE
4371
STREET_NUMBER
2121
Direction
N
STREET_NAME
ZUCKERMAN
STREET_TYPE
RD
City
STOCKTON
Zip
95206-
APN
12908009
ENTERED_DATE
10/28/2020 12:00:00 AM
SITE_LOCATION
2121 N ZUCKERMAN RD
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\fgarciaruiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6 710 <br /> AC POWER SOURCE <br /> 120V/240V <br /> #10 AWG WHITE <br /> NEUTRALCABLE <br /> E p 10 AWG BLACK HOT CABLE E <br /> #EE AWG RED HOT CABLE <br /> AC SAFETY NEEDED ONLY FOR 240V <br /> DISCONNECT SWITCH <br /> OPEN FUSE <br /> (ONLY USED FOR 240V) <br /> SECOND NEUTRAL BUS <br /> NOTE:EACH TERMINALON THE NUETRAL BUS CAN <br /> FUSE ONLY ACCEPT 1 WIRE.CONNECT TWO NUETRAL BUS <br /> WITH#30 GREEN <br /> #30 AWG GREEN p6 AWG BARE COPPER <br /> NEUTRAL BUS GROUND CABLE <br /> 2 0 a SO AWG BLACK HOT CABLE NOTES:LOWCURRENT(�30 AMPS) <br /> TG 1 <br /> p 10 AWG WHITE MECHANICAL RELAY PREWIRED TO SSD. <br /> '^ 24"DIA NEUTRALCABLE _ _ ZPTIETHE ACPROXIMITYSE.-SE. BLACK) <br /> NEAT SONOTUBE PROVIDING POWER TO THE TRANSFORMER INSIDE THE <br /> #10 AWG GREEN SCOUT ENCLOSURE. <br /> CEMENT <br /> GROUND CABLE <br /> G5 BOX AC TERMINAL GROUND RODS THE HMO AC SHOULD BE TERMINATED IN THE RMU <br /> ASSEMBLY BLOCK TERMINAL ON THE FRONT OF THE RECTIFIER,WHEN <br /> NOTE:RECTIFIERS WITH AVAILABLE.IF RMU TERMINAL IS NOT AVAILABLE <br /> SEPERATE OUTLET/RMU ON THE FRONT OF RECTIFIER,THE RMU AC SHOULD <br /> TERMINAL BLOCK tREIFIER GROUND BE TERMINATED IN THE AC TERMINAL BLOCK. <br /> 24"DIA MAY REQUIRE JUMPER MINAL <br /> SONOTUBE <br /> MU TERMINAL ON FRONT <br /> PGS F RECTIFIER <br /> RECTIFIER <br /> ' ®'•. POSITIVE(ANODE(OUTPUT <br /> NEAT G5 BOX NEGATIVE(CATHODE) TERMINAL <br /> CEMENT ASSEMBLY OUTPUT TERMINAL <br /> #6 AWG BLACK <br /> CATHODE CABLE COPPER SHORTING BUS <br /> C 50MV-SA SHUNT C <br /> ANODE JUNCTION BOX NUMBER TO MATCH <br /> DETAIL 6 NNON5-0AREA NUMBER OF ANODES <br /> PAVE <br /> SCALE:NTS 5 <br /> RMU AC TO THE <br /> TRANSFORMER <br /> p6AWG FROM EO OFSSDTO <br /> POSITIVE OF RECTIFIER <br /> SOMV-50A <br /> CATHODE SHUNT <br /> p8 AW G BLACK ANODE CABLE <br /> NUMBER TO MATCH <br /> BLACK CATHODE CABLE NUMBER OF ANODES <br /> (MINIMUM#8 AWGj <br /> g p 6 AWG BLACK/RED B <br /> PIPE ANODE BED ANODE CABLE <br /> FWHITE(NEUTRAL) <br /> MECHANICAL RELAY SSD �[y <br /> (PREWIRED TO SSD) <br /> TRANSFORMER GAS TRANS ' <br /> AC 2t 1- 4 <br /> HOT(BLACK) DETECT EST I MATING M1DES01GN <br /> RMU <br /> DETAIL S ED WIRING <br /> AGRAM <br /> POLEOIMOUNTED <br /> SCALE:NTS 30A OR LESS RECTIFIER <br /> 5 <br /> R <br /> A AI <br /> WARNING: uuaFpaR sx[FTI <br /> Data E__-,N-AR ® PIPELINE-DETAILS <br /> axnoFNMI I r L-057A-MSS MP0.00 <br /> ono W'C'aixrnni�cgniA"l , INSTALL DEEP VVELLANODE Ip C-1550 <br /> L'E&Eo�0a uiro L�Tar STOCKTON,SAN JOAQUIN COUNTY <br /> AUTHORIffaVA[iFIl GAS ANa Knpwwnars <br /> cONPARl IPS below ® aFOFaxcansmumox PACIFIC GAAxsNrnD�sswELECIACVFCroOx MPANY <br /> PSGNTS. A va[cD. canDelDTe,BDBI9. REVISIONS ANGSCO,CALIFORNIA <br /> sx7FFr4No0.36 12aF 29i wF0Fr <br /> s <br /> 1 2 $I 3 4 ,I 6 7 (8 9 10 P Axa <br />
The URL can be used to link to this page
Your browser does not support the video tag.