COOLER GENERAL NOTES GENERAL NOTES <br /> 3 <br /> C 1. COOLER INSULATION VALUES FOR WALLS, CEILING, AND DOORS 1. THIS DRAWING IS FOR EQUIPMENT LAYOUT PURPOSES ONLY. <br /> SHALL BE MIN. R-25 PLEASE SEE FLOOR PLAN FOR FULLY DIMENSIONED PARTITION <br /> C: ° LOCATIONS AND ASSEMBLIES. <br /> -o 2. AUTOMATIC DOOR CLOSERS SHALL BE PROVIDED THAT FULLY <br /> a o CLOSE WALK-IN DOORS THAT HAVE BEEN CLOSED TO WITHIN 1 2. NOTE: PLEASE SEE SHEET G1.0, COVER SHEET, FOR CODE <br /> w <br /> INCH OF FULL CLOSURE SUMMARY, BUILDING DATA AND EXIT ACCESS REQUIREMENTS. <br /> � o <br /> N 3. DOORWAYS SHALL HAVE STRIP DOORS, CURTAINS, 3. G.C. TO VERIFYALL DIMENSIONS IN THE FIELD BEFORE <br /> �; � SPRING-HINGED DOORS OR OTHER METHOD OF MINIMIZING COMMENCING CONSTRUCTION. Dn n�r((`'��I p �O� <br /> o C: INFILTRATION WHEN DOORS ARE OPEN <br /> 4. ALL FIRE EXTINGUISHERS SHALL BE STATE OF CALIFORNIA <br /> CERTIFIED. ALL FIRE EXTINGUISHERS SHALL BE BE PROPERLY/ <br /> z r 00000000000 00000000000 00000000000 00000000000 00000000000 00000000000 <br /> MOUNTED AT THE HEIGHT REQUIREMENTS OF NO HIGHER THAN <br /> 0 000000 000000 000000 000000 000000 000000 <br /> E o°o°o°0°0°6 0°0°0°0°0°6 0°0°0°0°0°6 0°0°0°0°0°6 0°0°0°0°0°6 0°0°0°0°0°6 4'-6"A.F.F. TO THE TOP OF THE EXTI N G U ISH ER AN D AT LEAST 6 <br /> C: Q o°o°o°o°o°o o°o°o°o°o°o o°o°o°o°o°o o°o°o°o°o°o o°o°o°o°o°o o°o°o°o°o°o <br /> D O 0.0.0.0.0_ _0.0.0.0.0_ _0.0.0.0.0_ _0.0.0.0.0_ _0.0.0.0.0_ _0.0.0.0.0_ FROM FLOOR TO THE BOTTOM OF EXTINGUISHER. (NFPA 10: <br /> X �_ - o°o°o�0°0�0 6.1.3.8) <br /> 0 Q N <br /> 00000a <br /> CV MILK CRATES BY OWNER °o° 5. ALL PROPERLY MOUNTED FIRE EXTINGUISHERS SHALL NOT <br /> +0 <br /> EXCEED 75'OF TRAVEL DISTANCE APART. (NFPA 1: 6.1) <br /> ui <br /> o E COOLER °oo ooa 6. FIRE EXTINGUISHERS SHALL BE CONSPICUOUSLY LOCATED <br /> O _ 00^ <br /> Q o °�o °� WHERE THEYARE READILY ACCESSIBLE AND IMMEDIATELY <br /> U <br /> a L ooh <br /> > <br /> 00 0 00 <br /> 0, AVAILABLE IN THE EVENT OF FIRE. (NFPA 10: 6.1.3) <br /> o c (3)2'-0"x 6'-0"GLASS DOORS °o o°o <br /> BY COOLER BOX MANUFACTURER I o0 0 <br /> � 000 7. FIRE EXTINGUISHERS SHALL BE LOCATED ALONG NORMAL <br /> o �o Q 000 1 2 3 PATHS OF TRAVEL, INCLUDING EXITS FROM AREAS. (NFPA 10: <br /> E o A7.0 A7.0 A7.0 6.1.3) <br /> 0000000000, <br /> o) 00000 8. FIRE EXTINGUISHERS SHALL NOT BE OBSTRUCTED OR <br /> " <br /> "' <br /> 3-0 x 6-8"DOOR °o°opo°oma <br /> Oo0o0o0o0oa OBSCURED FROM VIEW. (NFPA 10: 6.1.3.3) GNICH <br /> ARCHITECTURE <br /> BY COOLER BOX oo°o°o°o°oa LINE O F METAL <br /> 0 o MANUFACTURER. o°O°O°O°O°o <br /> o °�°�°�°�°�° AWNING, ABOVE. 7. TACTILE SIGNAGE SHALL BE PROVIDED AT ALL EXIT DOORS TO <br /> o Q MEET THE FOLLOWING CRITERIA: S T U D I O <br /> o DOWNSPOUTS TO A. TACTILE SIGNAGE SHALL BE LOCATED AT EACH EXIT DOOR <br /> r REQUIRING AN EXIT SIGN; <br /> CURB-O-LET BELOW A6.0 B. TACTILE SIGNAGE SHALL READ AS FOLLOWS: "EXIT'; <br /> -VERIFY W/ MANUF. EQ27 C. TACTILE SIGNAGE SHALL COMPLY WITH ICC/ANSI A117.1 <br /> C: ABV. <br /> o PRE-FAB INSULATED VERIFY WALL DIMENSIONS BLW EQ17 4 <br /> o COOLER BOX PANELS, AT COOLER DOOR; (2) 054 1001 SE SANDY BLVD, SUITE 100 <br /> o BY MANUFACTURER. ADJUST HINGE LOCATION AND COOLER <br /> CLEARANCES.DOOR <br /> EQ15 EQ14 E015 PORTLAND, OR 97214 <br /> o V. 503.552.9079 <br /> o g_p 3_p 1 _p F. 503.241.7055 <br /> _012'-0" <br /> LINE OF METAL WWW.GNICHARCH.COM <br /> 0 <br /> - AWNING, ABOVE. <br /> 0 T2 E 35 LW. Q27 DOWNSPOUTS TO 8 04.2 020 <br /> 2 ENLARGED COOLER PLAN EQ54 (2) ABv. CURB-O-LET BELOW � ' ' ' , <br /> E011 -VERIFY W/ MANUF. 7 A5.0 9C .16ERIK <br /> SCALE: 1/2" = F-0" E012 <br /> 0, � 2 6 n�aTrl�r s <br /> or No_ C-32764 <br /> E019 A1 .0 1 0A5.0 04 30-20 <br /> L E013 EQ14 <br /> 21 <br /> 0 <br /> ui E RENEWAL DATE <br /> BLW. <br /> ° EQ1Ll r - ' <br /> m EQ3 CAS <br /> -\ <br /> E§23 ABv. z Z � EQ4 <br /> o 4 E031 EQ37 P-1 / UNISEX <br /> A7.o <br /> 031 Q Q EQ16 AC��I B LE <br /> EQ16 m EQ23 A5.o �� REL WR00 M-1ELEC. <br /> EQ4I Q Q ABV. 2 5. k ROOM Q <br /> a E03 N N EQ1 �� _ -I C:) <br /> NT <br /> COOLER EQ13 E020 C:) <br /> E CL <br /> EQ7 5 EQ24 BLW. _ � EQ30 m <br /> O o <br /> 0 ° I EQ19 EQ29A BV. � 0 <br /> A5.0 u °I <br /> 0 A6.0 1 1 4I E012 E029 ----------� w ~ 3 A6.0 <br /> 5 I O P-2 v l <br /> � J I E011 E028 06 <br /> J EQ7 T5 ABV. - - CO J <br /> 3 ----------- a-a- �I O <br /> a � EQ23 <br /> ° 0) EQ3 ABV. - - EQ51 b M <br /> P1 P-15 EiV. vV <br /> U EQ4 E025 J � <br /> >, E012 T4 �� EQ21 I �L <br /> Q ,6 E016 <br /> QT LINE <br /> EQ5 BLW.ABV. Q <br /> EA <br /> L <br /> AWNING E031 E031 (4) v Z <br /> o °�' ABOVE 031 E013 E04 E018 E013 PRODUCTION I � <br /> EQ23 Q27 ABV. I . . � � (D <br /> ami rj EQ1 BLW. BLW. ABV. BLW. F_ � � E <br /> O <br /> Q v7 <br /> •� � A7.0 E013 E019 E013 EQ16 I I <br /> CD <br /> o BLW. EQ54 E012 BLW. EQ4 E033 z L� <br /> E E07 O - 01% > LO <br /> 6 E019 EQ23 P-10 U Q - <br /> E012 - <br /> ABV. E010 (2)ABV. c , (D � � Q <br /> o E 3 P-13 P-14 EQ36 v O U 0, U <br /> a C: E01 O -3 L <br /> a T3 EQ9 n 1 m � <br /> o T1 E Lw. EQ54 (2) - EQ1 �� OO OO O P-16 U X N <br /> 35� 0 � � � � � U � <br /> �' EQ11 O O C i m <br /> E � <br /> L <br /> D - CL Q <br /> 6 DOWNSPOUTS TO 014 E031 LINE OF METAL <br /> CURB BELOWQ54 (2) *BLW. <br /> 031 AWNING, ABOVE. ISSUED FOR PERMIT: <br /> 0 <br /> -VERIFY W/ MANUF. ABV. <br /> � <br /> DOWNSPOUTS TO 02. 14.20 <br /> CURB-O-LET BELOW <br /> -VERIFY W/ MANUF. <br /> 0 0 <br /> U <br /> U <br /> a REV: DATE: DESCRIPTION: <br /> .Q <br /> 1 04.29.2020 CITY COMMENTS <br /> u <br /> 0 <br /> 0 <br /> o cc <br /> - o <br /> LINE OF PRE-FAB <br /> CANOPY, ABOVE. <br /> o <br /> (0 O SHEET NAME: <br /> 0 0 <br /> DOWNSPOUTS TO � DOWNSPOUTS TO <br /> 2 EQUIPMENT PLAN/ <br /> C: <br /> CURB-O-LET BELOW CURB-O-LET BELOW ENLARGED PLANS <br /> 0 -VERIFY W/ MANUF. -VERIFY W/ MANUF. A6.0 <br /> m - <br /> U � <br /> C:, SHEET NUMBER: <br /> o <br /> -U J J EQUIPMENT PLAN J <br /> � U <br /> A1 . 0 <br /> Q) Q SCALE: 3/8" = F-0" 0' 2' 4' <br /> o <br /> o) 02019 DB Franchising USA, LLC <br />